PubMed Health⌕ Search

Biomedical subjects

Nicolaus Reifart

Publications and source records attributed to Nicolaus Reifart.

13 recordsLinked to original sources

A double-blind, randomized, placebo-controlled multicenter clinical trial to evaluate the effects of the angiotensin II receptor blocker candesartan cilexetil on intimal hyperplasia after coronary stent implantation.

BACKGROUND: Preclinical data suggest beneficial effects of angiotensin II receptor blockers (ARBs) on neointima formation after vascular injury. Preliminary clinical data, however, revealed conflicting results. The AACHEN trial was a double-blind, randomized, placebo-controlled clinical multicenter trial to evaluate the effects of candesartan cilexetil on intimal hyperplasia after coronary stent implantation. METHODS: A total of 120 patients (61 +/- 9 years, 83% male) were randomized to receive either 32 mg candesartan cilexetil (active) or placebo starting 7 to 14 days before elective coronary stent implantation. A follow-up angiography including intravascular ultrasound assessment of the target lesion was performed 24 +/- 2 weeks after stent implantation. The primary end point was defined as the difference in neointimal area between groups as assessed by intravascular ultrasound. Secondary end points included differences in angiographic parameters (ie, restenosis rate) and incidence of major cardiac events. RESULTS: The mean stent length measured 15.0 +/- 4.9 mm in the active and 14.6 +/- 5.7 mm in the placebo group (P = .81). There was no significant difference in neointimal area between groups (2.1 +/- 1.0 vs 2.1 +/- 1.5 mm2, P = 1.00), nor were there differences in angiographic end point parameters. Major cardiac event rates were not significantly different between treatment groups (8% vs 11%, P = .75). CONCLUSIONS: High-dose candesartan cilexetil therapy in patients with symptomatic coronary artery disease undergoing coronary stent implantation does not reduce clinical event rates, restenosis rates, or neointimal proliferation after elective stent implantation.

Aged↗

Percutaneous in situ coronary venous arterialization: a catheter-based procedure for coronary artery bypass.

Diffuse coronary artery disease is frequently untreatable by coronary artery bypass or angioplasty. Open chest surgical arterialization of the coronary venous system was successfully performed before the widespread use of coronary artery bypass grafting and has been applied in ungraftable patients thereafter. Percutaneous in situ coronary venous arterialization (PICVA) follows this surgical experience, using a series of unique catheter-based devices to arterialize isolated segments of coronary vein, forcing retroperfusion of severely ischemic myocardium. In a series of animals, this procedure had been shown to reduce ischemia and myocardial damage in an infarction model. In the PICVA European Safety trial, the first 11 percutaneous applications of catheter-based coronary bypass in humans revealed feasibility of the technique in highly symptomatic "no-option" patients. Despite two deaths and six failures to create the bypass, we continue to believe that on further development, the catheter-based coronary bypass can become a broad-based interventional application.

Cardiac Catheterization↗

High-dose 7-hexanoyltaxol-eluting stent with polymer sleeves for coronary revascularization: one-year results from the SCORE randomized trial.

OBJECTIVES: The Study to COmpare REstenosis Rate between QueST and QuaDDS-QP2 (SCORE) trial was a multicenter, randomized, open-label trial comparing the safety and performance of 13- and 17-mm QuaDDS stents (n = 126) (Quanam Medical Corp., Santa Clara, California/Boston Scientific Corp., Natick, Massachusetts) versus uncoated control stents (n = 140) in focal, de novo coronary lesions. BACKGROUND: The pioneering drug-delivery QuaDDS stent used four to six acrylate polymer sleeves, each loaded with 800 microg of the paclitaxel derivative 7-hexanoyltaxol. METHODS: Clinical end points were assessed at 1, 6, and 12 months post procedure. Quantitative coronary angiography and intravascular ultrasound were performed post procedure and at six-month follow-up. RESULTS: In the QuaDDS group, early stent thrombosis and myocardial infarction (MI) rates were significantly higher, leading to premature cessation of enrollment. For the QuaDDS group, the stent thrombosis rate increased from 3.2% to 10.3% between 1 and 12 months, associated with increased non-Q-wave MI and death rates. The angiographic restenosis rate at six months was reduced from 32.7% (control) to 7.4% (p < 0.0001). However, the primary end point was not met with six-month target vessel revascularization (TVR) rate as well as the composite major adverse cardiac event rates (cardiac death, MI, and TVR) comparable between groups. CONCLUSIONS: Despite angiographic indications of potential anti-restenotic benefit, increased rates of stent thrombosis, MI, and cardiac death associated with the QuaDDS stent show an unacceptable safety profile.

Aged↗

Comparison of neointimal formation in polymer-free paclitaxel stents versus stainless stents (from the ASPECT and ELUTES randomized clinical trials).

The investigators examined 326 pairs of angiograms from 2 randomized dose-finding (0.2 to 3.1 microg paclitaxel/mm(2) of stent surface area) clinical trials of polymer-free paclitaxel-eluting stents in de novo lesions (the ASian Paclitaxel-Eluting stent Clinical Trial [ASPECT] and the European evaLUation of Taxol Eluting Stent [ELUTES]). A dose-dependent effect was observed: the largest dose of paclitaxel in the 2 trials resulted in a significantly larger proportion of lesions at follow-up with <10% diameter stenosis (54% vs 16%, p = 0.00012 in ASPECT; 53% vs 21%, p = 0.013 in ELUTES) and with minimal luminal diameter located outside the stent compared with control stents (62% vs 20% in ASPECT, 48% vs 18% in ELUTES; p <0.05). Also, significantly shorter lesion lengths at 6-month follow-up were observed for the doses of 0.7 to 3.1 microg/mm(2) (p <0.03) relative to their respective lengths before the procedure compared with control stents.

Angiogenesis Inhibitors↗

Inhibition of restenosis with a paclitaxel-eluting, polymer-free coronary stent: the European evaLUation of pacliTaxel Eluting Stent (ELUTES) trial.

BACKGROUND: The use of a stent to deliver a drug may reduce in-stent restenosis. Paclitaxel interrupts the smooth muscle cell cycle by stabilizing microtubules, thereby arresting mitosis. METHODS AND RESULTS: On the basis of prior animal studies, the European evaLUation of the pacliTaxel Eluting Stent (ELUTES) pilot clinical trial (n=190) investigated the safety and efficacy of V-Flex Plus coronary stents (Cook Inc) coated with escalating doses of paclitaxel (0.2, 0.7, 1.4, and 2.7 microg/mm2 stent surface area) applied directly to the abluminal surface of the stent in de novo lesions compared with bare stent alone. The primary efficacy end point was angiographic percent diameter stenosis at 6 months. At angiographic follow-up, percent diameter stenosis was 33.9+/-26.7% in controls (n=34) and 14.2+/-16.6% in the 2.7-microg/mm2 group (n=31; P=0.006). Late loss decreased from 0.73+/-0.73 to 0.11+/-0.50 mm (P=0.002). Binary restenosis (> or =50% at follow-up) decreased from 20.6% to 3.2% (P=0.056), with no significant benefit from intermediate paclitaxel doses. Freedom from major adverse cardiac events in the highest (effective) dose group was 92%, 89%, and 86% at 1, 6, and 12 months, respectively (P=NS versus control). No late stent thromboses were seen in any treated group despite clopidogrel treatment for 3 months only. CONCLUSIONS: Paclitaxel applied directly to the abluminal surface of a bare metal coronary stent, at a dose density of 2.7 microg/mm2, reduced angiographic indicators of in-stent restenosis without short- or medium-term side effects.

Coronary Angiography↗

The NUGGET study: NIR ultra gold-gilded equivalency trial.

This study should clarify whether the gold-coated NIROYAL stent is equivalent to the stainless steel NIR stent. Patients were randomized to either NIR stent (n = 298) or a NIROYAL stent (n = 305). The primary endpoint was the minimum lumen diameter of the target lesion at 6 months postprocedure. Secondary endpoints focused on clinical events. At 30 days, adverse events were similar in both groups. At 6 months, the minimal lumen diameter was 1.83/1.64 mm (P < 0.001; 95% CI = 0.08-0.30) and the angiographic restenosis rate was 20.6%/37.7% (P < 0.001; 95% CI = -24.7 to -9.3) for NIR/NIROYAL. The 6-month MACE rates were NIR 7.4% and NIROYAL 10.5% (95% CI = -7.7 to 1.4). Compared to stainless steel stent, the NIROYAL stent demonstrated a smaller minimal lumen diameter, a higher late loss (i.e., higher neointimal hyperplasia in spite of a significantly better initial gain), with higher restenosis and similar MACE rates at 6 months.

Aged↗

Influence of doxycycline on clinical and angiographic outcome following percutaneous coronary intervention.

BACKGROUND: Infection with Chlamydia pneumoniae may be involved in atherosclerosis. Neointima proliferation after percutaneous coronary intervention (PCI) could be aggravated by proinflammatory action of chronic vascular chlamydial infection. We investigated the influence of doxycycline therapy on restenosis rate and adverse clinical event rates after PCI. METHODS: We followed 1,019 consecutive patients in a single center nonrandomized observational study. During a 3-month period, all patients having PCI (n = 541; treatment group) received oral doxycycline 100 mg/day for 50 days starting from the day of the procedure. A control group (n = 478) consisted of consecutive post-PCI patients recruited from immediately preceding (n = 250) and ensuing periods. Event rates were gained by questionnaires after 259 +/- 57 days. Restenosis rate was derived from the routine angiographic restudies after 172 +/- 15 days. RESULTS: No significant differences between treatment and control group were found in adverse clinical event rates (myocardial infarction: 0.7% vs 1.3%; repeat-PCI: 24.0% vs 20.9%; coronary bypass grafting: 5% vs 3.9%; overall death after 6 months: 3.5% vs 2.1%) and overall restenosis rate (21.6% vs 23.4%). A subgroup analysis of nondiabetic male smokers revealed a lower restenosis rate in the treatment group (10.9% vs 30.9%; P = 0.0195). CONCLUSION: Doxycycline therapy for 50 days following PCI does not appear to have a substantial influence on the clinical and angiographic outcome in unselected patients. The observed reduction in restenosis rate among nondiabetic male smokers defines a new hypothesis that should stimulate further investigations.

Aged↗

Initial multicenter experience with a novel distal protection filter during carotid artery stent implantation.

Atheroembolization resulting in transient or permanent neurologic impairment is the most common complication of catheter-based percutaneous carotid artery intervention. Protection of the distal cerebral vasculature during carotid stent implantation may enhance procedural safety. Carotid stent implantation with distal cerebral protection using the FilterWire EX was performed in 35 consecutive patients undergoing 36 procedures at six centers. The FilterWire was delivered and deployed successfully in all 36 cases, and embolic material was retrieved from 74% of procedures. The 30-day rate of major adverse events (death, major or minor stroke) was 0%. Transient ipsilateral periprocedural neurologic ischemia developed in two patients (5.7%), both resolving within 30 min. Distal cerebral protection with the FilterWire during carotid stenting is feasible and safe, results in capture and extraction of atheroembolic debris in the majority of patients while affording uninterrupted cerebral perfusion, and in this initial multicenter experience was associated with a high rate of procedural success without major complications.

Aged↗

Catheter-based coronary bypass: a development update.

Catheter-based coronary bypass has evolved since its origin in 1995. We present a status update of one version of catheter-based bypass, percutaneous in situ coronary venous arterialization (PICVA), its successes and failures, and the many questions and challenges that remain. Initial clinical experience with PICVA demonstrated promising mitigation of angina in no-option patients, but was complicated by a relatively low procedural completion rate and a high incidence of MACE. A great deal was learned in these initial cases. The system of devices is currently undergoing significant modification, and further clinical study is underway.

Cardiac Catheterization↗

[4th report of German Association of Cardiologists in private practice (BNK) on quality assurance in cardiac catheterization and coronary intervention 1999-2002].

The Society of German Cardiologists in private practice (BNK) reports about its project on quality assurance in invasive cardiology (QuIK). Results of a computerized data collection and analysis of cardiac catheterizations and interventions in the years 1999-2002 are presented. These results are compared with other registries. The QuIK-project is done voluntarily by 70% of the society's cardiologists who perform invasive methods. A total of 225,562 diagnostic and 64,895 interventional procedures are documented over the 4 years. Patient characteristics and procedural data kept unchanged. Complication rates were low (< 2%), MACE < 0.5%. There was a rising number of patients referred with acute myocardial infarction. Less time was used to complete procedures from 1 year to another. Two out of three of the centers underwent a monitoring/auditing process in 2002. The desirable post-interventional follow-up after discharge in all cases appears to be impossible to fulfill under the given economical circumstances.

Adult↗

Angiographic outcome after intracoronary X-Sizer helical atherectomy and thrombectomy: first use in humans.

The objective of this study was to evaluate the early angiographic outcome in the first human subjects who underwent intracoronary atherectomy and thrombectomy using the X-Sizer helical cutting and aspiration system. Percutaneous coronary interventions in patients with thrombo-occlusive disease or friable degenerative saphenous vein grafts are associated with considerable periprocedural morbidity and mortality, predominantly related to microscopic distal embolization. X-Sizer catheter system is a novel atherectomy and thrombectomy device that consists of a helix cutter connected to a handheld motor drive unit and a vacuum collection chamber for aspiration of excised atheroma, thrombus, and debris. Quantitative coronary angiography was obtained in 14 patients before and after X-Sizer extraction atherectomy with adjunctive balloon angioplasty and stenting. Thirteen native coronary arteries and one saphenous vein graft were treated. Mean preprocedural reference vessel diameter was 3.06 +/- 0.66 mm. There were 71.4% AHA/ACC type B2 and C lesions. Preprocedural thrombus was present in nine patients and total occlusion in 64% of cases. Minimal luminal diameter was increased from 0.29 +/- 0.47 mm to 1.32 +/- 0.64 mm, a gain of 1.04 +/- 0.69 mm after atherectomy. Final total gain was 1.47 +/- 0.61 mm. Mean diameter stenosis was reduced from 89.3% to a final residual stenosis of 14.4%. Postatherectomy distal embolization occurred in one patient who had heavy preprocedural thrombus burden. No episodes of perforation, distal coronary spasm, abrupt closure, or slow/no-reflow occurred. The angiographic analysis of the first cohort of human subjects suggests that X-Sizer helical atherectomy is a feasible method of removing occlusive tissue or thrombus in coronary artery disease with a low angiographic complication rate. A large-scale randomized phase II clinical trial is underway to determine the ultimate safety and efficacy of this device in thrombo-occlusive native coronary arteries and saphenous vein grafts.

Angioplasty, Balloon, Coronary↗

Initial clinical experience with distal protection using the FilterWire in patients undergoing coronary artery and saphenous vein graft percutaneous intervention.

Percutaneous coronary intervention (PCI) of saphenous vein grafts (SVG) and native coronary arteries may be associated with embolization of particulate debris into the distal microcirculation. The FilterWire uses a polyurethane filter bag contained on a radiopaque loop to trap embolic debris during native vessel and SVG intervention. The objectives of this study were to assess the feasibility and safety of the FilterWire during PCI and to examine the size and content of the particulate debris captured during SVG and native vessel intervention. Early angiographic, in-hospital, and 30-day clinical outcomes were reviewed in 35 patients with 36 lesions treated with the FilterWire during PCI. Lesions were located in 22 (61%) native coronary arteries and in 14 (39%) SVGs. Multivessel coronary artery disease was present in 75% of patients. Lesions were complex (ACC/AHA complexity B2 or C) in 81% of cases. The FilterWire was successfully delivered and deployed distal to the site of coronary intervention in 92% of lesions, including 95% of native vessels and 82% of SVG lesions. Embolic debris was entrapped in 82% of these cases. The average particulate debris had a mean major axis of 490 microm (range, 45-3,302 microm) and minor axis of 226 microm (range, 33-1,677 microm). Although reduced flow was common (36.1%) when the FilterWire was in place, there were no sustained episodes of abrupt closure and only one (2.8%) patient developed sustained no-reflow after FilterWire removal. Distal branch vessel embolization was found in four (11.1%) cases. Major adverse cardiac events occurred in 5 (14%) of 35 patients treated with the device, although 2 of these patients were evolving an acute myocardial infarction at the time of the procedure; in patients meeting the prospectively defined inclusion criteria, the major adverse cardiac event was 6%. These results suggest that the FilterWire is a feasible and safe method of collecting particulate debris released during SVG and native vessel coronary intervention. Its benefit over conventional therapy and other distal protection devices is currently under study.

Aged↗