PubMed Health⌕ Search

Biomedical subjects

Niels Grabow

Publications and source records attributed to Niels Grabow.

5 recordsLinked to original sources

Iliac anastomotic stenting with a biodegradable poly-L-lactide stent: a preliminary study after 1 and 6 weeks.

PURPOSE: To assess the technical feasibility, thrombogenicity, and biocompatibility of a new biodegradable poly-L-lactic acid (PLLA) anastomotic stent. METHODS: A polytetrafluoroethylene bifurcated graft was implanted in 17 pigs through a midline abdominal incision. After transverse graft incision, 17 316L stainless steel stents and 17 PLLA stents were randomly implanted at both iliac anastomotic sites and deployed with a 6-mm balloon under direct vision without angiography. Intended follow-up was 1 week in 6 pigs receiving oral acetylsalicylic acid (ASA) and in 7 pigs receiving ASA/clopidogrel; 4 pigs receiving ASA/clopidogrel were followed for 6 weeks. At the end of the study, the segments containing the stents were surgically explanted and processed for histology to measure the mean luminal diameter, intimal thickness, and the vascular injury and inflammation scores. RESULTS: Initial technical success of stent placement was achieved in all animals without rupture of the suture. Two pigs died (unrelated to the stent) at 3 days after operation (1 in groups A and B). At 1 week, all PLLA stents showed thrombotic occlusion with the use of ASA alone. In contrast, all PLLA stents remained patent with concurrent administration of ASA/clopidogrel. All metal stents were patent regardless of the antiplatelet regimen. The mean luminal diameter of patent PLLA stents (4.13+/-0.17 mm) was comparable to metal stents (4.27+/-0.35 mm, p=0.78) at 1 week, but significantly diminished at 6 weeks (3.21+/-0.44 versus 4.19+/-0.18 mm, p=0.005). Histological analysis showed no signs of excessive recoil. PLLA stents induced a higher inflammation score (1.79+/-0.56) and more intimal hyperplasia (0.34+/-0.11 mm) compared to metal stents [1.27+/-0.44 mm (p<0.001) and 0.18+/-0.04 mm (p=0.006), respectively] at 6 weeks. Vascular injury was comparable between PLLA and metal stents. CONCLUSION: Biodegradable PLLA stents showed higher thrombogenicity and reduced patency compared to metal stents during early follow-up. Although ASA and clopidogrel prevented thrombotic occlusion, the increased inflammatory response and neointima formation remain major concerns of PLLA stents. A solution to this problem might be the incorporation of anti-inflammatory drugs into the PLLA stent.

Absorbable Implants↗

Iliac anastomotic stenting with a sirolimus-eluting biodegradable poly-L-lactide stent: a preliminary study after 6 weeks.

PURPOSE: To assess technical feasibility and biocompatibility of a new biodegradable sirolimus-eluting poly-L-lactide (PLLA) vascular anastomotic stent. METHODS: A polytetrafluoroethylene bifurcated graft was implanted in 9 pigs through a midline abdominal incision. After transverse graft limb incision, 6 unloaded PLLAs, 6 sirolimus-loaded PLLAs, and 6 unloaded stainless steel (316L) stents were randomly implanted at both iliac anastomotic sites. Stents were deployed with a 6-mm balloon under direct vision without the use of angiography. Prior to sacrifice after 6 weeks, contrast-enhanced computed tomography (CT) was performed to determine patency of the target vessels. Stented segments were surgically explanted and processed for histology to measure the mean luminal diameter and intimal thickness and to assign vascular injury and inflammation scores. RESULTS: No animals were lost during the study period. All stented graft limbs were patent on CT and histology. At the anastomotic sites and iliac arteries, the mean luminal diameter of SIR-PLLA stents (4.11+/-0.15 and 4.08+/-0.13 mm, respectively) were comparable to metal stents (4.23+/-0.35 and 4.21+/-0.26 mm, respectively), but significantly higher compared to unloaded PLLA stents [3.32+/-0.56 mm (p<0.001) and 3.29+/-0.39 mm (p=0.013), respectively]. At the iliac arteries, the mean intimal thickness was significantly lower with SIR-PLLA stents (0.09+/-0.02 mm) compared to unloaded PLLA stents (0.31+/-0.15 mm, p<0.001) and metal stents (0.19+/-0.04 mm, p=0.004). Vascular injury scores demonstrated only mild vascular trauma for all stents (SIR-PLLA: 0.42+/-0.63, PLLA: 0.51+/-0.62, metal: 0.50+/-0.62). Only mild inflammatory reaction was noted around SIR-PLLA stent struts (1.14+/-0.46), which was comparable to metal stents (1.27+/-0.45) but significantly lower than PLLA stents (1.79+/-0.56, p<0.001). CONCLUSION: SIR-PLLA stents showed comparable luminal diameter compared to metal stents, so incorporating sirolimus could reduce the inflammatory and neointimal response to PLLA stents. These findings need to be assessed with longer follow-up to confirm maintenance of efficacy.

Absorbable Implants↗

Mechanical properties of laser cut poly(L-lactide) micro-specimens: implications for stent design, manufacture, and sterilization.

BACKGROUND: The development of endoluminal stents from polymeric materials requires an understanding of the basic mechanical properties of the polymer and the effects of manufacturing and sterilization on those properties. METHODS: Pure poly(L-lactide) (PLLA) and PLLA containing varying amounts of triethylcitrate (TEC) as a plasticizer (5-10-15%) were studied. The specimens were solution-cast and CO2 laser-cut. Specimen dimensions were adapted to the strut size of polymeric vascular stents. The properties of the PLLA micro-specimens were assessed before and after sterilization (EtO cold gas, H2O2-plasma, beta- and gamma-irradiation). Tensile tests, and creep and recovery tests were carried out at 37 degrees C. Additionally the thermal and thermo-mechanical characteristics were investigated using dynamic-mechanical analysis (DMA) and differential scanning calorimetry (DSC). RESULTS: The results showed the dramatic influence of the plasticizer content and sterilization procedure on the mechanical properties of the material. Laser cutting had a lesser effect. Hence the effects of processing and sterilization must not be overlooked in the material selection and design phases of the development process leading to clinical use. Altogether, the results of these studies provide a clearer understanding of the complex interaction between the laser machining process and terminal sterilization on the primary mechanical properties of PLLA and PLLA plasticized with TEC.

Biocompatible Materials↗

Biomatrix/polymer composite material for heart valve tissue engineering.

BACKGROUND: Decellularized extracellular matrix has been suggested as a scaffold for heart valve tissue engineering or direct implantation. However, cell removal impairs the physical properties of the valve structure and exposes bare collagen fibers that are highly thrombogenic. Matrix/polymer hybrid valves with improved biological and mechanical characteristics may be advantageous. METHODS: Porcine aortic valves were decellularized enzymatically and impregnated with biodegradable poly(hydroxybutyrate) by a stepwise solvent exchange process. Biocompatibility was tested in vitro using cell proliferation and coagulation assays. Proinflammatory activity was assessed in vivo by implantation of matrix/polymer patches in the rabbit aorta. Biomechanic valve properties and fluid dynamics were tested in a pressure/flow-controlled pulse duplicating system. Matrix/polymer hybrid valves were implanted in pulmonary and aortic position in sheep. RESULTS: Biocompatibility assays indicated that human blood vessel cells survive and proliferate on matrix/polymer hybrid tissue. In vitro activation of cellular and plasmatic coagulation cascades was lower than with uncoated control tissue. After implantation in the rabbit aorta, matrix/polymer hybrid patches healed well, with complete endothelialization, mild leukocyte infiltration, and less calcification than control tissue. Matrix/polymer hybrid tissue had superior tensile strength and suture retention strength, and hybrid valves showed good fluid dynamic performance. The two valves in aortic position performed well, with complete endothelialization and limited inflammatory cell invasion after 12 weeks. Of the two valves in pulmonary position, one failed. CONCLUSIONS: Matrix/polymer hybrid tissue valves have good biological and biomechanic characteristics and may provide superior replacement valves.

Absorbable Implants↗

Mechanical and structural properties of a novel hybrid heart valve scaffold for tissue engineering.

Hybrid heart valve scaffolds were fabricated from decellularized porcine aortic heart valve matrices and enhanced with bioresorbable polymers using different protocols: (i) dip coating of lyophilized decellularized matrices, and (ii) impregnation of wet decellularized matrices. The following polymers were evaluated: poly(4-hydroxybutyrate) and poly(3-hydroxybutyrate-co4-hydroxybutyrate). Tensile tests were conducted to assess the biomechanical behavior of valve leaflet strips. Suture retention strength was evaluated for the adjacent conduit. A pulse duplicator system was used for functional testing of the valves under physiological systemic load conditions. The properties of the hybrid structures were compared with native, decellularized, and glutaraldehyde-fixed specimens. Mechanisms of the polymer impregnation process were studied with IR spectroscopy, fluorescent microscopic imaging, and SEM. Altogether this study demonstrates the feasibility and improved biomechanical function of a novel hybrid heart valve scaffold for an application in tissue engineering.

Animals↗