PubMed Health⌕ Search

Biomedical subjects

Niels Lion

Publications and source records attributed to Niels Lion.

13 recordsLinked to original sources

Multitrack electrospray chips.

Multitrack electrospray chips (MTEC) were fabricated by UV-photoablation of polyethylene terephthalate (PET) substrates. They are composed of an array of up to six microchannels that are successively used as electrospray ionization (ESI) emitters for mass spectrometry (MS). There is no requirement for alignment of the different spraying microchannels with the mass spectrometer orifice. The MTEC is thus fixed in front of the mass spectrometer and the successive MS analyses are performed without moving the chip. The sequential electrospraying by successive application of an identical high voltage in each off-axis microchannel was evaluated for the fast screening of peptides and proteins. The counting of cysteines in peptides through chemical modification and the relative quantification of a peptide in two samples are presented herein as two original strategies based on this new analytical tool.

Journal Article↗

On-line counting of cysteine residues in peptides during electrospray ionization by electrogenerated tags and their application to protein identification.

The electrochemically induced mass spectrometric tagging of cysteines by substituted hydroquinones was studied for peptides in a classical electrospray solvent (i.e., MeOH/H2O/AcOH 50/49/1). The tagging efficiency was tested with different hydroquinone compounds on an undecapeptide containing one cysteine residue. 2-carboxymethylhydroquinone was the most reactive probe and revealed to be suitable for cysteine quantification in peptides containing up to three cysteine residues, even in the case of two consecutive cysteines in the sequence. We demonstrate the compatibility of the on-line electrochemical tagging method for the cysteine content analysis of peptides coming from gel-free protein digestion procedures. The identification of bovine serum albumin and human alpha-lactalbumin digest samples in a peptide mapping strategy was greatly improved by the application of the electrotagging technique as post-column treatment. Indeed, the determination of cysteine content in the tryptic peptides provided powerful information in order to enhance the identification score as well as the discrimination against other protein candidates. The tagging method was then applied to the determination of four proteins in a model mixture.

Animals↗

Salt removal during Off-Gel electrophoresis of protein samples.

The Off-Gel technology was recently described for protein fractionation in a solution placed on top of an immobilized pH gradient gel. In addition, this process was found to remove salts from the biological samples to analyze. This desalting effect is studied experimentally in a conductometric prototype cell. A simplified analytical model is developed to understand this process and a good agreement is found with the conductivity measurements. To illustrate the desalting of a biological sample, a 1 mg.mL(-1) solution of beta-lactoglobulin A in 0.1 M NaCl is subjected to electrophoresis in a single compartment Off-Gel cell. The analysis of the resulting sample by ESI-MS demonstrates the effective removal of salt. A finite element diffusion-migration model is also used to illustrate how the nonuniformity of the electric field in the cell, associated with the salt migration, can slow down the desalting process.

Electric Conductivity↗

Chip electrospray mass spectrometry for carbohydrate analysis.

Currently two types of chip systems are used in conjunction with MS: out-of-plane devices, where hundreds of nozzles, nanospray emitters are integrated onto a single silicon substrate from which electrospray is established perpendicular to the substrate, and planar microchips, embedding a microchannel at the end of which electrospray is generated in-plane, on the edge of the microchip. In the last two years, carbohydrate research greatly benefited from the introduction and implementation of the chip-based MS. In two laboratories the advantages of the chip electrospray in terms of ionization efficiency, sensitivity, reproducibility, quality of data in combination with high mass accuracy, and resolution of detection were systematically explored for several carbohydrate classes: O- and N-glycopeptides, oligosaccharides, gangliosides and glycoprotein-derived O- and N-glycans, and glycopeptides. The current state-of-the-art in interfacing the chip electrospray devices to high-performance MS for carbohydrate analysis, and the particular requirements for method optimization in both positive and negative ion modes are reviewed here. The recent applications of these miniaturized devices and their general potential for glycomic-based surveys are highlighted.

Amino Acid Sequence↗

SPS' Digest: the Swiss Proteomics Society selection of proteomics articles.

Despite the consolidation of the specialized proteomics literature around a few established journals, such as Proteomics, Molecular and Cellular Proteomics, and the Journal of Proteome Research, a lot of information is still spread in many different publications from different fields, such as analytical sciences, MS, bioinformatics, etc. The purpose of SPS' Digest is to gather a selection of proteomics articles, to categorize them, and to make the list available on a periodic basis through a web page and email alerts.

Animals↗

Thin chip microsprayer system coupled to quadrupole time-of-flight mass spectrometer for glycoconjugate analysis.

A thin chip polymer-based microsprayer has been coupled to a hybrid quadrupole time-of-flight mass spectrometer (QTOF MS) and introduced in carbohydrate research. The feasibility of the approach is demonstrated for mapping, sequencing and structural elucidation of glycoconjugates originating from human body fluids and tissues such as a glycopeptide mixture from normal human urine and an isolated and purified GT1 ganglioside fraction from normal adult human brain. The optimization procedure required by each glycoconjugate category is described and the advantages of the system in terms of flexibility and adaptability to QTOF MS, stability of the ESI MS signal, carbohydrate ionization and sequencing, sensitivity, speed of analysis and sample consumption are discussed.

Amino Acids↗

Flow-rate characterization of microfabricated polymer microspray emitters.

Microfabricated polymer microspray emitters are characterized in terms of applicable flow rates, temporal and spectral signal-to-noise ratios (SNRs), and solution composition. First, microspray emitters can be operated with 50% methanol/49% water/1% acetic acid from 250 nL/min up to 7 microL/min, with better SNRs above 1 microL/min. Interestingly, even at the lowest flow rates tested, they compare well with nanospray capillaries in terms of mass spectral performances. Secondly, they can be operated with acetonitrile from 10 up to 99% (v/v), with flow rates from 250 nL/min up to 4 microL/min. Even if the mass spectral performances (especially the spectral SNRs) vary with the acetonitrile content, this study validates such microfabricated microspray emitters as interfaces between liquid-phase separations and electrospray mass spectrometers.

Microchemistry↗

A thin chip microsprayer system coupled to Fourier transform ion cyclotron resonance mass spectrometry for glycopeptide screening.

A thin polymer microchip was coupled with a Fourier transform ion cyclotron resonance (FTICR) 9.4 T mass spectrometer and the method was optimized in negative ion mode for glycopeptide screening. The interface between the polymer microchip and FTICR mass spectrometer consists of an in-laboratory conceived and designed mounting system that exhibits robust and controllable alignment of the chip toward the inlet of the mass spectrometer. The particular attribute of the polymer chip coupled to the FTICR mass spectrometer, to achieve an increase in ionization efficiency and sensitivity under the premise of high mass accuracy of detection, is highlighted by the large number of major and minor glycopeptide structures detected and identified in highly heterogeneous mixtures obtained from urine matrices. Glycoforms expressing various saccharide chain lengths ranging from tri- to dodecasaccharide, bearing up to three sialic acid moieties, could be detected and assigned based on the accuracy of the mass measurement (average mass deviation below 6 ppm) of their molecular ions. -Thin chipESI-FTICRMS is a potent novel system for glycomic screening of complex mixtures, as demonstrated for identification of singly sialylated O-glycosylated amino acids and peptides from urine matrices, and could be considered for general applicability in the glycoanalytical field.

Amino Acid Sequence↗

Why the move to microfluidics for protein analysis?

There has been a recent trend towards the miniaturization of analytical tools, but what are the advantages of microfluidic devices and when is their use appropriate? Recent advances in the field of micro-analytical systems can be classified according to instrument performance (which refers here to the desired property of the analytical tool of interest) and two important features specifically related to miniaturisation, namely reduction of the sample volume and the time-to-result. Here we discuss the contribution of these different parameters and aim to highlight the factors of choice in the development and use of microfluidic devices dedicated to protein analysis.

Animals↗

Generation of mass tags by the inherent electrochemistry of electrospray for protein mass spectrometry.

We present herein a review of our work on the on-line electrochemical generation of mass tags toward cysteine residues in peptides and proteins. Taking advantage of the inherent electrochemical nature of electrospray generated from a microfabricated microspray emitter, selective probes for cysteine were developed and tested for on-line nonquantitative mass tagging of peptides and proteins. The nonquantitative aspect of the covalent tagging thus allows direct counting of free cysteines in the mass spectrum of a biomolecule through additional adduct peaks. Several substituted hydroquinones were investigated in terms of electrochemical properties, and their usefulness for on-line mass tagging during microspray experiments were assessed with L-cysteine, peptides, and intact proteins. Complementarily, numerical simulations were performed to properly understand the respective roles of mass transport, kinetics of electrochemical-chemical reactions, and design of the microspray emitter in the mass tagging overall efficiency. Finally, the on-line electrochemical tagging of cysteine residues was applied to the analysis of tryptic peptides of purified model proteins for protein identification through peptide mass fingerprinting.

Cysteine↗

On-chip protein sample desalting and preparation for direct coupling with electrospray ionization mass spectrometry.

A membrane-based desalting step integrated in a MS microchip is presented: drugs, peptides and proteins are adsorbed on a hydrophobic poly(vinylidene difluoride) membrane, which allows the washing out of salts. The integration with microfluidics permits a controlled elution of analytes from the membrane and their direct mass spectrometric analysis by electrospray ionisation MS. The desalting process is demonstrated with picomole amounts of propanolol, insulin and cytochrome c. Moreover, this stop-and-go desalting process is tolerant to high concentrations of urea, and to the presence of reductants such as dithiothreitol. This particular feature allowed the chemical tagging of cysteines in beta-lactoglobulin A with iodoacetamide. Finally, the integration of chemical tagging, on-chip desalting and MS microchip paves the way for the development of high-throughput analytical procedure for structural proteomics.

Adsorption↗

Microfluidic systems in proteomics.

We present the state-of-the-art in miniaturized sample preparation, immunoassays, one-dimensional and multidimensional analyte separations, and coupling of microdevices with electrospray ionization-mass spectrometry. Hyphenation of these different techniques and their relevance to proteomics will be discussed. In particular, we will show that analytical performances of microfluidic analytical systems are already close to fulfill the requirements for proteomics, and that miniaturization results at the same time in a dramatic increase in analysis throughput. Throughout this review, some examples of analytical operations that cannot be achieved without microfluidics will be emphasized. Finally, conditions for the spreading of microanalytical systems in routine proteomic labs will be discussed.

Electrophoresis↗

Integration of a membrane-based desalting step in a microfabricated disposable polymer injector for mass spectrometric protein analysis.

A simple desalting procedure for the coupling of a polymer microchip injector to mass spectrometry is proposed. The overall process is based on the adsorption of proteins on a poly(vinylidene difluoride) (PVDF) membrane, which are then directly eluted in the spraying solution. This microchip-based approach has been successfully applied to small drugs, peptides and proteins originally diluted in phosphate-buffered saline (PBS). Moreover, when eluting the retained proteins in small volumes, a preconcentration is obtained. The combination of single-use, mass-produceable, low-sample-consumption, easy-to-automate, miniaturized polymer injectors with easy-to-handle solution-exchange membranes makes this system particularly amenable to screening applications.

Angiotensin II↗