PubMed Health⌕ Search

Biomedical subjects

Nigel Shrive

Publications and source records attributed to Nigel Shrive.

2 recordsLinked to original sources

Modelling the behaviour of ligaments: a technical note.

Experimental observations suggest that during a ligament tensile strain test, water and glycosaminoglycans are exuded. Many attempts have been tried to model this behaviour using continuum mechanics. We have investigated this unique behaviour and have established three mechanisms which may contribute to the experimental observations: the slackness of the fibres before stretching can lead to a decrease in volume upon straightening; a Poisson's ratio higher than 0.5 from the axial to the lateral direction (as recorded in the literature [Hewitt, J., Guilak, F., Glisson, R. and Parker Vail, T. (2001) "Regional material properties of the human hip joint capsule ligaments", Journal of Orthopaedic Research 19(3), 359-364]) due to the very high level of anisotropy of the tissue; and an osmotic pressure, with a certain level of anisotropy, that causes the swelling of the tissue before loading [Thornton, G.M., Shrive, N.G. and Frank, C.B. (2001) "Altering ligament water content affects ligament pre-stress and creep behaviour", Journal of Orthopaedic Research 19(5), 845-851]. There may be other mechanisms that also contribute in the observed fluid exudation on tensile loading.

Anisotropy↗

A new method to measure post-traumatic joint contractures in the rabbit knee.

A new device and method to measure rabbit knee joint angles are described. The method was used to measure rabbit knee joint angles in normal specimens and in knee joints with obvious contractures. The custom-designed and manufactured gripping device has two clamps. The femoral clamp sits on a pinion gear that is driven by a rack attached to a materials testing system. A 100 N load cell in series with the rack gives force feedback. The tibial clamp is attached to a rotatory potentiometer. The system allows the knee joint multiple degrees-of-freedom (DOF). There are two independent DOF (compression-distraction and internal-external rotation) and two coupled motions (medial-lateral translation coupled with varus-valgus rotation; anterior-posterior translation coupled with flexion-extension rotation). Knee joint extension-flexion motion is measured, which is a combination of the materials testing system displacement (converted to degrees of motion) and the potentiometer values (calibrated to degrees). Internal frictional forces were determined to be at maximum 2% of measured loading. Two separate experiments were performed to evaluate rabbit knees. First, normal right and left pairs of knees from four New Zealand White (NZW) rabbits were subjected to cyclic loading. An extension torque of 0.2 Nm was applied to each knee. The average change in knee joint extension from the first to the fifth cycle was 1.9 deg +/- 1.5 deg (mean +/- sd) with a total of 49 tests of these eight knees. The maximum extension of the four left knees (tested 23 times) was 14.6 deg +/- 7.1 deg, and of the four right knees (tested 26 times) was 12.0 deg +/- 10.9 deg. There was no significant difference in the maximum extension between normal left and right knees. In the second experiment, nine skeletally mature NZW rabbits had stable fractures of the femoral condyles of the right knee that were immobilized for five, six or 10 weeks. The left knee served as an unoperated control. Loss of knee joint extension (flexion contracture) was demonstrated for the experimental knees using the new methodology where the maximum extension was 35 deg +/- 9 deg, compared to the unoperated knee maximum extension of 11 deg +/- 7 deg, 10 or 12 weeks after the immobilization was discontinued. The custom gripping device coupled to a materials testing machine will serve as a measurement test for future studies characterizing a rabbit knee model of post-traumatic joint contractures.

Animals↗