PubMed Health⌕ Search

Biomedical subjects

Nil Grousson

Publications and source records attributed to Nil Grousson.

2 recordsLinked to original sources

Ventriculo-aortic junction in human root. A geometric approach.

With advances in tissue engineering and improvement of surgical techniques, stentless biological valves and valve-sparing procedures have become alternatives to traditional aortic valve replacement with stented bioprostheses or mechanical valves. New surgical techniques preserve the advantages of native valves but require better understanding of the anatomical structure of the aortic root. Silicone rubber was injected in fresh aortic roots of nine human cadavers under the physiological closing pressure of 80 mmHg. The casts reproduced every detail of the aortic root anatomy and were used to digitize 27 leaflet attachment lines (LALs) of the aortic valves. LALs were normalized and described with a mathematical model. LALs were found to follow a pattern with the right coronary being the largest followed by the non-coronary and then the left coronary. During diastole, the aortic valve LAL can be described by an intersection between a created tube and an extruded parabolic surface. This geometrical definition of the LAL during end diastole gives a better understanding of the aortic root anatomy and could be useful for heart valve design and improvement of aortic valve reconstruction technique.

Adult↗

Forces at single point attached commissures (SPAC) in pericardial aortic valve prosthesis.

OBJECTIVE: New pericardial aortic bioprostheses (3F Therapeutics and temporarily stented autologous pericardial valve prosthesis) were developed recently. These valves are designed with commissures connected to the aortic wall at only three single points (single point attached commissures (SPAC)). The aim of this study was to investigate the forces acting on SPAC during varying pressure load. METHODS: Aortic roots with diameters 19, 25, and 29 mm were made using silicone polymer. A bovine pericardial SPAC aortic valve prosthesis was constructed using a 3D-mold and was implanted in the silicone aortic root. The base of the valve was sutured onto the aortic annulus with 4-0 polypropylene running suture and each commissure was sutured to a miniaturized force transducer with only one 3-0 polypropylene U-stitch. Three silicon aortic roots of each size were pressurized up to 200 mmHg and forces on SPAC were measured. RESULTS: All valves remained competent at a pressure of 200 mmHg. Recordings showed a linear correlation between applied pressure and forces measured at SPAC. At a pressure of 80 mmHg (equivalent to diastolic pressure), the forces were 0.44+/-0.22N, 1.15+/-0.18N, and 2.00+/-0.35N in annular diameters 19 mm, 25 mm, and 29 mm, respectively. It was observed, that the main forces were acting along the axial direction and not along the radial direction. CONCLUSIONS: Forces on "single point attached commissures" in pericardial aortic valves were measured. These forces were acting mainly in axial direction and not in radial direction. This knowledge is important for the implantation technique of SPAC pericardial aortic valves.

Animals↗