PubMed Health⌕ Search

Biomedical subjects

Nilam C Shah

Publications and source records attributed to Nilam C Shah.

4 recordsLinked to original sources

Surface enhanced Raman spectroscopy: new materials, concepts, characterization tools, and applications.

Surface-enhanced Raman spectroscopy (SERS) is currently experiencing a renaissance in its development driven by the remarkable discovery of single molecule SERS (SMSERS) and the explosion of interest in nanophotonics and plasmonics. Because excitation of the localized surface plasmon resonance (LSPR) of a nanostructured surface or nanoparticle lies at the heart of SERS, it is important to control all of the factors influencing the LSPR in order to maximize signal strength and ensure reproducibility. These factors include material, size, shape, interparticle spacing, and dielectric environment. All of these factors must be carefully controlled to ensure that the incident laser light maximally excites the LSPR in a reproducible manner. This article describes the use of nanosphere lithography for the fabrication of highly reproducible and robust SERS substrates for both fundamental studies and applications. Atomic layer deposition (ALD) is introduced as a novel fabrication method for dielectric spacers to study the SERS distance dependence and control the nanoscale dielectric environment. Wavelength scanned SER excitation spectroscopy (WS SERES) measurements show that enhancement factors approximately 10(8) are obtainable from NSL-fabricated surfaces and provide new insight into the electromagneticfield enhancement mechanism. Tip-enhanced Raman spectroscopy (TERS) is an extremely promising new development to improve the generality and information content of SERS. A 2D correlation analysis is applied to SMSERS data. Finally, the first in vivo SERS glucose sensing study is presented.

Biosensing Techniques↗

Real-time glucose sensing by surface-enhanced Raman spectroscopy in bovine plasma facilitated by a mixed decanethiol/mercaptohexanol partition layer.

A new, mixed decanethiol (DT)/mercaptohexanol (MH) partition layer with dramatically improved properties has been developed for glucose sensing by surface-enhanced Raman spectroscopy. This work represents significant progress toward our long-term goal of a minimally invasive, continuous, reusable glucose sensor. The DT/MH-functionalized surface has greater temporal stability, demonstrates rapid, reversible partitioning and departitioning, and is simpler to control compared to the tri(ethylene glycol) monolayer used previously. The data herein show that this DT/MH-functionalized surface is stable for at least 10 days in bovine plasma. Reversibility is demonstrated by exposing the sensor alternately to 0 and 100 mM aqueous glucose solutions (pH approximately 7). The difference spectra show that complete partitioning and departitioning occur. Furthermore, physiological levels of glucose in two complex media were quantified using multivariate analysis. In the first system, the sensor is exposed to a solution consisting of water with 1 mM lactate and 2.5 mM urea. The root-mean-squared error of prediction (RMSEP) is 92.17 mg/dL (5.12 mM) with 87% of the validation points falling within the A and B range of the Clarke error grid. In the second, more complex system, glucose is measured in the presence of bovine plasma. The RMSEP is 83.16 mg/dL (4.62 mM) with 85% of the validation points falling within the A and B range of the Clarke error grid. Finally, to evaluate the real-time response of the sensor, the 1/e time constant for glucose partitioning and departitioning in the bovine plasma environment was calculated. The time constant is 28 s for partitioning and 25 s for departitioning, indicating the rapid interaction between the SAM and glucose that is essential for continuous sensing.

Animals↗

Glucose sensing using near-infrared surface-enhanced Raman spectroscopy: gold surfaces, 10-day stability, and improved accuracy.

This research presents the achievement of significant milestones toward the development of a minimally invasive, continuously monitoring, glucose-sensing platform based on the optical quantitation of glucose in interstitial fluid. We expand our initial successes in the measurement of glucose by surface-enhanced Raman scattering (SERS), demonstrating substantial improvements not only in the quality and optical properties of the substrate system itself but also in the robustness of the measurement methodology and the amenability of the technique to compact, diode laser-based instrumentation. Herein, we compare the long-term stability of gold to silver film over nanosphere (AuFON, AgFON) substrates functionalized with a partitioning self-assembled monolayer (SAM) using both electrochemical and SERS measurements. AuFONs were found to be stable for a period of at least 11 days. The switch to AuFONs not only provides a more stable surface for SAM formation but also yields better chemometric results, with improved calibration and validation over a range of 0.5-44 mM (10-800 mg/dL). Measured values for glucose concentrations in phosphate-buffered saline (pH approximately 7.4) based on 160 independent SERS measurements on AuFONs have a root-mean-square error of prediction of 2.7 mM (49.5 mg/dL), with 91% of the values falling within an extended A-B range on an expanded Clarke error grid. Furthermore, AuFONs exhibit surface plasmon resonances at longer wavelengths than similar AgFONs, which make them more efficient for SERS at near-infrared wavelengths, enabling the use of low-power diode lasers in future devices.

Glucose↗

Dynamic mechanical analysis of storage modulus development in light-activated polymer matrix composites.

OBJECTIVES: The goal of this study was to evaluate the potential for using dynamic mechanical analysis of tubular geometry in a three-point flexure fixture for monitoring the storage modulus development of a light-activated polymer matrix composite. METHODS: Composite samples were inserted into PTFE tubes and tested in a three-point bend fixture in a dynamic mechanical analyzer (DMA) at 200 Hz with 20 microm amplitude. Samples were light activated for 60s (385 mW/cm(2) at the composite surface) and storage modulus (E') was measured continuously for the seven light-activated composites studied (one microfill, four hybrids and two unfilled resins). Cores of composite were removed from the PTFE sheath after 13.5 min and evaluated with the same parameters in the DMA. A finite element model of the test configuration was created and used to estimate operating parameters for the DMA. Degree of conversion (DC) was measured using micro-Fourier Transform Infrared (FTIR) spectroscopy for the microfilled composite samples and one hybrid 13.5 and 60 min after light activation. RESULTS: The E' for a generic hybrid and microfilled composite was 13,400+/-1100 and 5900+/-200 MPa, respectively, when cured within the tube and then removed and tested in the DMA. DC was 54.6% for the hybrid and 60.6% for the microfill. A linear regression of E' for the sheath and core vs core alone (r(2)=0.986) indicated a linear scaling of the sheath and core values for E' enabling a correction for estimated E' values of the composite core. SIGNIFICANCE: This method estimates the storage modulus growth during light-activated polymerization of highly filled dimethacrylates. Although the approach is phenomenological in that quantitative measurements of E' are not made directly from the DMA, estimates of early polymerization kinetics appear to be validated by three different approaches.

Barium Compounds↗