Location of innervation zone determined with multichannel surface electromyography using an optical flow technique.

Multichannel surface electromyography has developed towards more channels and higher spatial resolution. This allows the study of multichannel electromyograms as images of the potential distribution on the skin. In this paper, a method that estimates the motion of the potential distribution using an optical-flow-based technique is introduced. The optical flow is a vector field that describes how images change with time. The aim of this study was to introduce a new method for innervation zone (IZ) localization and to evaluate its performance. The new method was compared with a method that uses the position of the lowest root-mean-square (RMS) value in an electrode array as an estimate of the IZ localization. Comparisons were made with both simulated signals and with recorded multichannel electromyogram signals. Simulations showed that the methods performed similarly for high signal-to-noise ratio (SNR) and that the optical-flow-based method was superior for lower SNR. When the experimental signals were used, localization with the optical-flow-based method gave a mean absolute deviation of 2.4mm from the location given by an expert group. The lowest RMS method gave a significantly higher deviation (13.6mm). Due to the low computational complexity of the optical flow algorithm it is possible to get the estimations of the IZ localization in real time.

Action Potentials↗

Adaptive spatio-temporal filtering of multichannel surface EMG signals.

A motor unit (MU) is defined as an anterior horn cell, its axon, and the muscle fibres innervated by the motor neuron. A surface electromyogram (EMG) is a superposition of many different MU action potentials (MUAPs) generated by active MUs. The objectives of this study were to introduce a new adaptive spatio-temporal filter, here called maximum kurtosis filter (MKF), and to compare it with existing filters, on its performance to detect a single MUAP train from multichannel surface EMG signals. The MKF adaptively chooses the filter coefficients by maximising the kurtosis of the output. The proposed method was compared with five commonly used spatial filters, the weighted low-pass differential filter (WLPD) and the marginal distribution of a continuous wavelet transform. The performance was evaluated using simulated EMG signals. In addition, results from a multichannel surface EMG measurement fro from a subject who had been previously exposed to radiation due to cancer were used to demonstrate an application of the method. With five time lags of the MKF, the sensitivity was 98.7% and the highest sensitivity of the traditional filters was 86.8%, which was obtained with the WLPD. The positive predictivities of these filters were 87.4 and 80.4%, respectively. Results from simulations showed that the proposed spatio-temporal filtration technique significantly improved performance as compared with existing filters, and the sensitivity and the positive predictivity increased with an increase in number of time lags in the filter.

Action Potentials↗

Improved maximum frequency estimation with application to instantaneous mean frequency estimation of surface electromyography.

The purpose of this study was to improve the maximum-frequency estimation. Three methods to estimate the maximum frequency of a bandlimited signal with additive white noise were compared. Two existing methods, the threshold-crossing method (TCM) and the hybrid method, were modified for time-frequency representations. A novel approach, the running-block threshold method (RBTM), was introduced. Based on calculation of detection probability (sensitivity) the RBTM improved the maximum-frequency estimate as compared with the TCM. The maximum-frequency estimation methods were also used to determine the integration interval for instantaneous mean-frequency (IMNF) estimation from synthesized surface electromyography containing white noise. Results showed that the IMNF estimate was improved by using any of the three methods and that the RBTM gave the best IMNF estimate.