PubMed Health⌕ Search

Biomedical subjects

Nirmal Soni

Publications and source records attributed to Nirmal Soni.

4 recordsLinked to original sources

Enhancing the performance of model-based elastography by incorporating additional a priori information in the modulus image reconstruction process.

Model-based elastography is fraught with problems owing to the ill-posed nature of the inverse elasticity problem. To overcome this limitation, we have recently developed a novel inversion scheme that incorporates a priori information concerning the mechanical properties of the underlying tissue structures, and the variance incurred during displacement estimation in the modulus image reconstruction process. The information was procured by employing standard strain imaging methodology, and introduced in the reconstruction process through the generalized Tikhonov approach. In this paper, we report the results of experiments conducted on gelatin phantoms to evaluate the performance of modulus elastograms computed with the generalized Tikhonov (GTK) estimation criterion relative to those computed by employing the un-weighted least-squares estimation criterion, the weighted least-squares estimation criterion and the standard Tikhonov method (i.e., the generalized Tikhonov method with no modulus prior). The results indicate that modulus elastograms computed with the generalized Tikhonov approach had superior elastographic contrast discrimination and contrast recovery. In addition, image reconstruction was more resilient to structural decorrelation noise when additional constraints were imposed on the reconstruction process through the GTK method.

Algorithms↗

Excitation patterns in three-dimensional electrical impedance tomography.

Electrical impedance tomography (EIT) is a non-invasive technique that aims to reconstruct images of internal electrical properties of a domain, based on electrical measurements on the periphery. Improvements in instrumentation and numerical modeling have led to three-dimensional (3D) imaging. The availability of 3D modeling and imaging raises the question of identifying the best possible excitation patterns that will yield to data, which can be used to produce the best image reconstruction of internal properties. In this work, we describe our 3D finite element model of EIT. Through singular value decomposition as well as examples of reconstructed images, we show that for a homogenous female breast model with four layers of electrodes, a driving pattern where each excitation plane is a sinusoidal pattern out-of-phase with its neighboring plane produces better qualitative images. However, in terms of quantitative imaging an excitation pattern where all electrode layers are in phase produces better results.

Algorithms↗

On optimal current patterns for electrical impedance tomography.

We develop a statistical criterion for optimal patterns in planar circular electrical impedance tomography. These patterns minimize the total variance of the estimation for the resistance or conductance matrix. It is shown that trigonometric patterns (Isaacson, 1986), originally derived from the concept of distinguishability, are a special case of our optimal statistical patterns. New optimal random patterns are introduced. Recovering the electrical properties of the measured body is greatly simplified when optimal patterns are used. The Neumann-to-Dirichlet map and the optimal patterns are derived for a homogeneous medium with an arbitrary distribution of the electrodes on the periphery. As a special case, optimal patterns are developed for a practical EIT system with a finite number of electrodes. For a general nonhomogeneous medium, with no a priori restriction, the optimal patterns for the resistance and conductance matrix are the same. However, for a homogeneous medium, the best current pattern is the worst voltage pattern and vice versa. We study the effect of the number and the width of the electrodes on the estimate of resistivity and conductivity in a homogeneous medium. We confirm experimentally that the optimal patterns produce minimum conductivity variance in a homogeneous medium. Our statistical model is able to discriminate between a homogenous agar phantom and one with a 2 mm air hole with error probability (p-value) 1/1000.

Algorithms↗

Using multiple-electrode impedance measurements to monitor cryosurgery.

We outfitted cryoprobes with electrodes and used them in conjunction with a multiple channel electrical impedance tomography (EIT) system to record data during freezing experiments in a shallow saline tank. We made measurements using electrodes mounted on the probes and the tank's periphery. Reconstructed images based on both sets of electrodes indicate a significant improvement in the appearance of the ice ball over using tank electrodes alone. The size of the ice balls was varied by deliberately altering the cooling rate. We found a positive correlation between the measured size of the ice ball and the sizes of isocontour lines in the reconstructed impedance maps. Similarly, the shape of the ice balls was altered by circulating the saline about the probe. Two-dimensional reconstructed impedance contours indicated a deformation in agreement with the shape of the ice ball during the experiments. These findings suggest that using multielectrode impedance sensing may constitute a means for monitoring cryosurgery.

Biophysical Phenomena↗