Biological dose calculation with Monte Carlo physics simulation for heavy-ion radiotherapy.

Treatment planning of heavy-ion radiotherapy involves predictive calculation of not only the physical dose but also the biological dose in a patient body. The biological dose is defined as the product of the physical dose and the relative biological effectiveness (RBE). In carbon-ion radiotherapy at National Institute of Radiological Sciences, the RBE value has been defined as the ratio of the 10% survival dose of 200 kVp x-rays to that of the radiation of interest for in vitro human salivary gland tumour cells. In this note, the physical and biological dose distributions of a typical therapeutic carbon-ion beam are calculated using the GEANT4 Monte Carlo simulation toolkit in comparison with those with the biological dose estimate system based on the one-dimensional beam model currently used in treatment planning. The results differed between the GEANT4 simulation and the one-dimensional beam model, indicating the physical limitations in the beam model. This study demonstrates that the Monte Carlo physics simulation technique can be applied to improve the accuracy of the biological dose distribution in treatment planning of heavy-ion radiotherapy.

Carbon↗

Extended collimator model for pencil-beam dose calculation in proton radiotherapy.

We have developed a simple collimator model to improve the accuracy of penumbra behaviour in pencil-beam dose calculation for proton radiotherapy. In this model, transmission of particles through a three-dimensionally extended opening of a collimator is calculated in conjunction with phase-space distribution of the particles. Comparison of the dose distributions calculated using the new three-dimensional collimator model and the conventional two-dimensional model to lateral dose profiles experimentally measured with collimated proton beams showed the superiority of the new model over the conventional one.

Algorithms↗

Physical evaluation of CT scan methods for radiation therapy planning: comparison of fast, slow and gating scan using the 256-detector row CT scanner.

Although slow-rotation CT scanning (slow-scan CT: SSCT) has been used for radiation therapy planning, based on the rationale that the average duration of the human respiratory cycle is 4 s, a number of physical and quantitative questions require answering before it can be adopted for clinical use. This study was performed to evaluate SSCT physically in comparison with other scan methods, including respiratory-gated CT (RGCT), and to develop procedures to improve treatment accuracy. Evaluation items were geometrical accuracy, volume accuracy, water equivalent length and dose distribution using the 256-detector row CT with three scan methods. Fast-scan CT (FSCT) was defined as obtaining all respiratory phases in cine scan mode at 1.0 s per rotation. FSCT-ave was the averaged FSCT images in all respiratory phases, obtained by reconstructing short time intervals. SSCT has been defined as scanning with slow gantry rotation to capture the whole respiratory cycle in one rotation. RGCT was scanned at the most stable point in the respiratory cycle, which provides the same image as that by FSCT at the most stable point. Results showed that all evaluation items were dependent on motion characteristics. The findings of this study indicate that 3D planning based solely on SSCT under free breathing may result in underdosing of the target volume and increase toxicity to surrounding normal tissues. Of the three methods, RGCT showed the best ability to significantly increase the accuracy of dose distribution, and provided more information to minimize the margins. FSCT-ave is a satisfactory radiotherapy planning alternative if RGCT is not available.

Algorithms↗

Commissioning of a conformal irradiation system for heavy-ion radiotherapy using a layer-stacking method.

The commissioning of conformal radiotherapy system using heavy-ion beams at the Heavy Ion Medical Accelerator in Chiba (HIMAC) is described in detail. The system at HIMAC was upgraded for a clinical trial using a new technique: large spot uniform scanning with conformal layer stacking. The system was developed to localize the irradiation dose to the target volume more effectively than with the old system. With the present passive irradiation method using a ridge filter, a scatterer, a pair of wobbler magnets, and a multileaf collimator, the width of the spread-out Bragg peak (SOBP) in the radiation field could not be changed. With dynamic control of the beam-modifying devices during irradiation, a more conformal radiotherapy could be achieved. In order to safely perform treatments with this conformal therapy, the moving devices should be watched during irradiation and the synchronousness among the devices should be verified. This system, which has to be safe for patient irradiations, was constructed and tested for safety and for the quality of the dose localization realized. Through these commissioning tests, we were successfully able to prepare the conformal technique using layer stacking for patients. Subsequent to commissioning the technique has been applied to patients in clinical trials.

Calibration↗

Tumour shapes and fully automated range compensation for heavy charged particle radiotherapy.

The idea of a computer-controlled range-compensating system for heavy charged particle radiotherapy, the multibar compensator, is proposed. By stacking multiple energy-absorbing layers along the beam, each of which has structure and behaviour similar to those of a multileaf collimator, variable range compensation will be achieved. The analysis of the conventional range compensators actually used for treatment concluded that the proposed system would not seriously degrade the treatment quality for the most cases, except for tumours in the head and neck region where 1 mm precision may be required. The system will even be able to coexist with the conventional range compensators to provide either method depending on clinical situations.

Automation↗

Experimental evaluation of analytical penumbra calculation model for wobbled beams.

The goal of radiotherapy is not only to apply a high radiation dose to a tumor, but also to avoid side effects in the surrounding healthy tissue. Therefore, it is important for carbon-ion treatment planning to calculate accurately the effects of the lateral penumbra. In this article, for wobbled beams under various irradiation conditions, we focus on the lateral penumbras at several aperture positions of one side leaf of the multileaf collimator. The penumbras predicted by an analytical penumbra calculation model were compared with the measured results. The results calculated by the model for various conditions agreed well with the experimental ones. In conclusion, we found that the analytical penumbra calculation model could predict accurately the measured results for wobbled beams and it was useful for carbon-ion treatment planning to apply the model.

Algorithms↗

Evaluation of a pencil beam algorithm for therapeutic carbon ion beam in presence of bolus.

Hot- and cold-dose spots at a shallow depth in a target are formed by carbon ions passing through the bolus with sharp gradients. These spots are caused by sidescatter disequilibrium due to various multiple scattering effects in the different bolus thicknesses. When the dose calculation method by the broad beam algorithm (BBA) is used for treatment planning, these spots cannot be predicted, because the BBA neglects the multiple scattering effects in materials (rms error of 3.9%). On the other hand, since the dose calculation method by the pencil beam algorithm (PBA) takes into account the scattering effects, the results calculated by the PBA agreed better than the BBA with the measured hot- and cold-dose spots, having a rms error of 1.9%. Thus, dose calculation by the PBA improves the accuracy of dose prediction at the shallow depth. However, since dose distributions at deeper positions are affected by many light fragment particles generated by fragment reactions, the results calculated by the PBA disagree with the experimental ones. It is necessary that even the PBA accurately models behavior of fragment particles.

Algorithms↗

A CT calibration method based on the polybinary tissue model for radiotherapy treatment planning.

A method to establish the relationship between CT number and effective density for therapeutic radiations is proposed. We approximated body tissues to mixtures of muscle, air, fat and bone. Consequently, the relationship can be calibrated only with a CT scan of their substitutes, for which we chose water, air, ethanol and potassium phosphate solution, respectively. With simple and specific corrections for non-equivalencies of the substitutes, a calibration accuracy of 1% will be achieved. We tested the calibration method with some biological materials to verify that the proposed method would offer the accuracy, simplicity and specificity required for a standard in radiotherapy treatment planning, in particular with heavy charged particles.

Adipose Tissue↗

Quality control of CT system for treatment planning using the polybinary calibration method.

A guideline for quality assurance of CT systems for radiotherapy treatment planning is proposed. Quantitative interpretation of CT number is very important especially for range calculation in heavy charged particle radiotherapy, for which we adopted the polybinary calibration method to correct variations among CT systems and scanning conditions. Practical procedures for commissioning and constancy testing are documented along with the methodologies against various sources of uncertainty. We propose this guideline for quality assurance of heavy charged particle radiotherapy.

Calibration↗

Treatment planning for the layer-stacking irradiation system for three-dimensional conformal heavy-ion radiotherapy.

We have upgraded a heavy-ion radiotherapy treatment-planning system to adapt for the layer-stacking irradiation method, which is to conform a variable spread-out Bragg peak to a target volume by means of dynamic control of the conventional beam-modifying devices. The biophysical model, the beam-setup logic, and the dose-calculation algorithm implemented for the layer-stacking method are described and the expected clinical usability is discussed. The layer-stacking method was integrated in perfect accordance with the ongoing conventional treatments so that the established protocols, which are the clinically optimized dose fractionation schemes, will still be valid. On the other hand, a simulation study indicated a substantial improvement of dose distribution with the layer-stacking method though the significance may depend on the size, shape, and location of the tumor. The completed treatment system will provide an option for improved conformal radiotherapy without interfering with the conventional method and we expect a gradual expansion of the clinical cases applicable to the layer-stacking method.

Algorithms↗