Calculation of effective dose from measurements of secondary neutron spectra and scattered photon dose from dynamic MLC IMRT for 6 MV, 15 MV, and 18 MV beam energies.

Effective doses were calculated from the delivery of 6 MV, 15 MV, and 18 MV conventional and intensity-modulated radiation therapy (IMRT) prostate treatment plans. ICRP-60 tissue weighting factors were used for the calculations. Photon doses were measured in phantom for all beam energies. Neutron spectra were measured for 15 MV and 18 MV and ICRP-74 quality conversion factors used to calculate ambient dose equivalents. The ambient dose equivalents were corrected for each tissue using neutron depth dose data from the literature. The depth corrected neutron doses were then used as a measure of the neutron component of the ICRP protection quantity, organ equivalent dose. IMRT resulted in an increased photon dose to many organs. However, the IMRT treatments resulted in an overall decrease in effective dose compared to conventional radiotherapy. This decrease correlates to the ability of an intensity-modulated field to minimize dose to critical normal structures in close proximity to the treatment volume. In a comparison of the three beam energies used for the IMRT treatments, 6 MV resulted in the lowest effective dose, while 18 MV resulted in the highest effective dose. This is attributed to the large neutron contribution for 18 MV compared to no neutron contribution for 6 MV.

Humans↗

Determination of dosimetric characteristics of OptiSeed(TM) a plastic brachytherapy (103)Pd source.

A new (103)Pd plastic brachytherapy source, OptiSeed(TM) Model 1032P, is being introduced by International Brachytherapy sa (IBt). Measurements of the dose distributions about the source were performed using LiF thermoluminescent dosimeters (TLD-100) in Virtual Water(TM). MCNP5 calculations were performed to determine the dose distributions in Virtual Water(TM) and liquid water. The source dose rate constant, radial dose function, anisotropy function and anisotropy factor have been determined following the updated AAPM TG-43 recommendations. The measured dose rate constant in the Virtual Water(TM) phantom was determined to be 0.727+/-6.9% cGyh(-1)U(-1), and the computed value is 0.716+/-2.1% cGyh(-1)U(-1). The Monte-Carlo simulation yielded a dose rate constant of 0.665+/-2.1% cGyh(-1)U(-1) in water. The measured dose rate constant in water is 0.675+/-7.5% cGyh(-1)U(-1). It is determined by multiplying the dose rate constant measured in the Virtual Water(TM) phantom with the ratio of the value calculated in water to that in Virtual Water(TM). The average of the measured and calculated dose rate constant is 0.670+/-5.5% cGyh(-1)U(-1). The radial dose functions of the new source were measured for distances ranging from 1 to 7 cm in a Virtual Water(TM) phantom. The anisotropy functions in Virtual Water(TM) phantom were measured for distances of 2, 3, 5, and 7 cm. The Monte-Carlo computed radial dose functions, anisotropy functions, and anisotropy factors in both Virtual Water(TM) phantom and water are reported.

Brachytherapy↗

Measurements of secondary neutron dose from 15 MV and 18 MV IMRT.

Secondary neutron dose-equivalents were determined for conventional and intensity modulated radiation therapy (IMRT) prostate treatments for 15 and 18 MV X-ray beams. Conventional and IMRT treatment plans were generated to deliver 45 Gy to the prostate, seminal vessicles and external and internal iliac lymph nodes. Neutron spectra were determined by unfolding measurements from a TLD-based Bonner sphere system. Treatments using 18 MV IMRT and conventional plans result in neutron ambient dose-equivalents of 687 and 112 mSv, respectively. Delivery of the 15 MV IMRT and conventional plans results in neutron ambient dose-equivalents of 327 and 52 mSv, respectively. The data illustrate that using lower photon energies for IMRT reduces the secondary neutron dose, while still achieving comparable treatment volume coverage and sparing critical normal tissue.

Body Burden↗

A time-dependent dose model for glovebox processing of fissile material.

A new modeling system for high-intensity neutral particle radiation fields is presented. The code PANDEMONIUM calculates external effective dose rates from neutrons and photons produced at specific locations within an industrial-size plutonium processing facility. The new version of PANDEMONIUM introduces time-dependent neutronics for source multiplication coupled with transient source and detector positions. The code is designed to provide quick and acceptably accurate total effective dose estimates for scenarios and facilities for which conventional methods prove to be too impractical or costly to model. The energy range of the code has also been extended to include the effects of prompt-fission photons.

Computer Simulation↗

Bremsstrahlung doses from natural uranium ingots.

In the past, some privately owned commercial facilities in the United States were involved in producing or processing radioactive materials used in the production of atomic weapons. Seven different geometrical objects, representative of the configurations of natural uranium metal potentially encountered by workers at these facilities, are modelled to determine gamma ray and bremsstrahlung dose rates. The dose rates are calculated using the MCNP5 code and also by using the MICROSHIELD point-kernel code. Both gamma ray and bremsstrahlung dose rates are calculated and combined to obtain a total dose rate. The two methods were found to be in good agreement despite differences in modelling assumptions and method differences. Computed total dose rates on the surface of these objects ranged from approximately 51-84 microSv h(-1) and 17-95 microSv h(-1) using the MCNP5 and the MICROSHIELD modeling, respectively. The partitioning of the computed dose rates between gamma rays and bremsstrahlung were the same order of magnitude for each object.

Computer Simulation↗

A comparison of skyshine computational methods.

A variety of methods employing radiation transport and point-kernel codes have been used to model two skyshine problems. The first problem is a 1 MeV point source of photons on the surface of the earth inside a 2 m tall and 1 m radius silo having black walls. The skyshine radiation downfield from the point source was estimated with and without a 30-cm-thick concrete lid on the silo. The second benchmark problem is to estimate the skyshine radiation downfield from 12 cylindrical canisters emplaced in a low-level radioactive waste trench. The canisters are filled with ion-exchange resin with a representative radionuclide loading, largely 60Co, 134Cs and 137Cs. The solution methods include use of the MCNP code to solve the problem by directly employing variance reduction techniques, the single-scatter point kernel code GGG-GP, the QADMOD-GP point kernel code, the COHORT Monte Carlo code, the NAC International version of the SKYSHINE-III code, the KSU hybrid method and the associated KSU skyshine codes.

Air↗

Investigation of secondary neutron dose for 18 MV dynamic MLC IMRT delivery.

Secondary neutron doses from the delivery of 18 MV conventional and intensity modulated radiation therapy (IMRT) treatment plans were compared. IMRT was delivered using dynamic multileaf collimation (MLC). Additional measurements were made with static MLC using a primary collimated field size of 10 x 10 cm2 and MLC field sizes of 0 x 0, 5 x 5, and 10 x 10 cm2. Neutron spectra were measured and effective doses calculated. The IMRT treatment resulted in a higher neutron fluence and higher dose equivalent. These increases were approximately the ratio of the monitor units. The static MLC measurements were compared to Monte Carlo calculations. The actual component dimensions and materials for the Varian Clinac 2100/2300C including the MLC were modeled with MCNPX to compute the neutron fluence due to neutron production in and around the treatment head. There is excellent agreement between the calculated and measured neutron fluence for the collimated field size of 10 x 10 cm2 with the 0 x 0 cm2 MLC field. Most of the neutrons at the detector location for this geometry are directly from the accelerator head with a small contribution from room scatter. Future studies are needed to investigate the effect of different beam energies used in IMRT incorporating the effects of scattered photon dose as well as secondary neutron dose.

Body Burden↗

Mammographic x-ray unit kilovoltage test tool based on k-edge absorption effect.

A simple tool to determine the peak kilovoltage (kVp) of a mammographic x-ray unit has been designed. Tool design is based on comparing the effect of k-edge discontinuity of the attenuation coefficient for a series of element filters. Compatibility with the mammography accreditation phantom (MAP) to obtain a single quality control film is a second design objective. When the attenuation of a series of sequential elements is studied simultaneously, differences in the absorption characteristics due to the k-edge discontinuities are more evident. Specifically, when the incident photon energy is higher than the k-edge energy of a number of the elements and lower than the remainder, an inflection may be seen in the resulting attenuation data. The maximum energy of the incident photon spectra may be determined based on this inflection point for a series of element filters. Monte Carlo photon transport analysis was used to estimate the photon transmission probabilities for each of the sequential k-edge filter elements. The photon transmission corresponds directly to optical density recorded on mammographic x-ray film. To observe the inflection, the element filters chosen must have k-edge energies that span a range greater than the expected range of the end point energies to be determined. For the design, incident x-ray spectra ranging from 25 to 40 kVp were assumed to be from a molybdenum target. Over this range, the k-edge energy changes by approximately 1.5 keV between sequential elements. For this design 21 elements spanning an energy range from 20 to 50 keV were chosen. Optimum filter element thicknesses were calculated to maximize attenuation differences at the k-edge while maintaining optical densities between 0.10 and 3.00. Calculated relative transmission data show that the kVp could be determined to within +/-1 kV. To obtain experimental data, a phantom was constructed containing 21 different elements placed in an acrylic holder. MAP images were used to determine appropriate exposure techniques for a series of end point energies from 25 to 35 kVp. The average difference between the kVp determination and the calibrated dial setting was 0.8 and 1.0 kV for a Senographe 600 T and a Senographe DMR, respectively. Since the k-edge absorption energies of the filter materials are well known, independent calibration or a series of calibration curves is not required.

Absorption↗