PubMed Health⌕ Search

Biomedical subjects

Norbert J Pelc

Publications and source records attributed to Norbert J Pelc.

At least 19 recordsLinked to original sources

Articular cartilage of the knee: rapid three-dimensional MR imaging at 3.0 T with IDEAL balanced steady-state free precession--initial experience.

Institutional review board approval and informed consent were obtained for this HIPAA-compliant study. In this study, iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) balanced steady-state free precession (bSSFP), fat-suppressed bSSFP, and fat-suppressed spoiled gradient-echo (GRE) sequences for 3.0-T magnetic resonance (MR) imaging of articular knee cartilage were prospectively compared in five healthy volunteers. Cartilage and fluid signal-to-noise ratio (SNR), cartilage-fluid contrast-to-noise ratio (CNR), SNR efficiency, CNR efficiency, image quality, and fat suppression were compared. Fat-suppressed bSSFP and IDEAL bSSFP had higher SNR efficiency of cartilage (P < .01) than did GRE. IDEAL bSSFP had higher cartilage-fluid CNR efficiency than did fat-suppressed bSSFP or GRE (P < .01). Fat-suppressed bSSFP and IDEAL bSSFP had higher image quality than did GRE (P < .01). GRE and IDEAL bSSFP had significantly better fat-water separation or fat saturation than did fat-suppressed bSSFP (P < .05). IDEAL bSSFP is a promising method for imaging articular knee cartilage.

Adult↗

Allometric scaling of wall shear stress from mice to humans: quantification using cine phase-contrast MRI and computational fluid dynamics.

Allometric scaling laws relate structure or function between species of vastly different sizes. They have rarely been derived for hemodynamic parameters known to affect the cardiovascular system, e.g., wall shear stress (WSS). This work describes noninvasive methods to quantify and determine a scaling law for WSS. Geometry and blood flow velocities in the infrarenal aorta of mice and rats under isoflurane anesthesia were quantified using two-dimensional magnetic resonance angiography and phase-contrast magnetic resonance imaging at 4.7 tesla. Three-dimensional models constructed from anatomic data were discretized and used for computational fluid dynamic simulations using phase-contrast velocity imaging data as inlet boundary conditions. WSS was calculated along the infrarenal aorta and compared between species to formulate an allometric equation for WSS. Mean WSS along the infrarenal aorta was significantly greater in mice and rats compared with humans (87.6, 70.5, and 4.8 dyn/cm(2), P < 0.01), and a scaling exponent of -0.38 (R(2) = 0.92) was determined. Manipulation of the murine genome has made small animal models standard surrogates for better understanding the healthy and diseased human cardiovascular system. It has therefore become increasingly important to understand how results scale from mouse to human. This noninvasive methodology provides the opportunity to serially quantify changes in WSS during disease progression and/or therapeutic intervention.

Animals↗

T1- and T2-weighted fast spin-echo imaging of the brachial plexus and cervical spine with IDEAL water-fat separation.

PURPOSE: To compare the iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) method with fat-saturated T1-weighted (T1W) and T2W fast spin-echo (FSE) and short-TI inversion recovery (STIR) imaging of the brachial plexus and cervical spine. MATERIALS AND METHODS: Images acquired at 1.5T in five volunteers using fat-saturated T1W and T2W FSE imaging and STIR were compared with T1W and T2W IDEAL-FSE images. Examples of T1W and T2W IDEAL-FSE images acquired in patients are also shown. RESULTS: T1W and T2W IDEAL-FSE demonstrated superior fat suppression (P<0.05) and image quality (P<0.05), compared to T1W and T2W fat-saturated FSE, respectively. SNR performance of T1W-IDEAL-FSE was similar to T1W FSE in the spinal cord (P=0.250) and paraspinous muscles (P=0.78), while T2W IDEAL-FSE had superior SNR in muscle (P=0.02) and CSF (P=0.02), and marginally higher cord SNR (P=0.09). Compared to STIR, T2W IDEAL-FSE demonstrated superior image quality (P<0.05), comparable fat suppression (excellent, P=1.0), and higher SNR performance (P<0.001). CONCLUSION: IDEAL-FSE is a promising method for T1W and T2W imaging of the brachial plexus and cervical spine.

Adipose Tissue↗

Single acquisition water-fat separation: feasibility study for dynamic imaging.

Water-fat separation can be challenging in the presence of field inhomogeneities. Three-point (3-pt) water-fat separation methods achieve robust performance by measuring and compensating for field inhomogeneities; however, they triple the scan time. The "1+-pt" water-fat separation method proposed in this article for dynamic or repetitive imaging situations combines 3-pt methods' ability to correct for field inhomogeneities with the scan efficiency of a single acquisition method to achieve high temporal and spatial resolutions and robust water-fat separation. Single-echo data are collected with water and fat at a relative phase shift of an odd multiple of pi/2. To correct for undesired phase modulation, phase maps are estimated from a 3-pt calibration scan acquired prior to dynamic imaging. The phase maps are assumed to be slowly varying in time, so they may be used for correcting the phase of the subsequent single-echo signals at the same imaging location. Noise performance was investigated and shown to be equivalent to a single excitation acquisition. The 1+-pt method can also be used in conjunction with parallel imaging. In this situation, the calibration scans required by both methods can be integrated into a shared calibration scan. Promising results were obtained in breast, abdominal, and cardiac imaging applications.

Abdomen↗

A prototype table-top inverse-geometry volumetric CT system.

A table-top volumetric CT system has been implemented that is able to image a 5-cm-thick volume in one circular scan with no cone-beam artifacts. The prototype inverse-geometry CT (IGCT) scanner consists of a large-area, scanned x-ray source and a detector array that is smaller in the transverse direction. The IGCT geometry provides sufficient volumetric sampling because the source and detector have the same axial, or slice direction, extent. This paper describes the implementation of the table-top IGCT scanner, which is based on the NexRay Scanning-Beam Digital X-ray system (NexRay, Inc., Los Gatos, CA) and an investigation of the system performance. The alignment and flat-field calibration procedures are described, along with a summary of the reconstruction algorithm. The resolution and noise performance of the prototype IGCT system are studied through experiments and further supported by analytical predictions and simulations. To study the presence of cone-beam artifacts, a "Defrise" phantom was scanned on both the prototype IGCT scanner and a micro CT system with a +/-5 cone angle for a 4.5-cm volume thickness. Images of inner ear specimens are presented and compared to those from clinical CT systems. Results showed that the prototype IGCT system has a 0.25-mm isotropic resolution and that noise comparable to that from a clinical scanner with equivalent spatial resolution is achievable. The measured MTF and noise values agreed reasonably well with theoretical predictions and computer simulations. The IGCT system was able to faithfully reconstruct the laminated pattern of the Defrise phantom while the micro CT system suffered severe cone-beam artifacts for the same object. The inner ear acquisition verified that the IGCT system can image a complex anatomical object, and the resulting images exhibited more high-resolution details than the clinical CT acquisition. Overall, the successful implementation of the prototype system supports the IGCT concept for single-rotation volumetric scanning free from cone-beam artifacts.

Algorithms↗

Cardiac CINE imaging with IDEAL water-fat separation and steady-state free precession.

PURPOSE: To decompose multicoil CINE steady-state free precession (SSFP) cardiac images acquired at short echo time (TE) increments into separate water and fat images, using an iterative least-squares "Dixon" (IDEAL) method. MATERIALS AND METHODS: Multicoil CINE IDEAL-SSFP cardiac imaging was performed in three volunteers and 15 patients at 1.5 T. RESULTS: Measurements of signal-to-noise ratio (SNR) matched theoretical expectations and were used to optimize acquisition parameters. TE increments of 0.9-1.0 msec permitted the use of repetition times (TRs) of 5 msec or less, and provided good SNR performance of the water-fat decomposition, while maintaining good image quality with a minimum of banding artifacts. Images from all studies were evaluated for fat separation and image quality by two experienced radiologists. Uniform fat separation and diagnostic image quality was achieved in all images from all studies. Examples from volunteers and patients are shown. CONCLUSION: Multicoil IDEAL-SSFP imaging can produce high quality CINE cardiac images with uniform water-fat separation, insensitive to Bo inhomogeneities. This approach provides a new method for reliable fat-suppression in cardiac imaging.

Adult↗

Co-registration of x-ray and MR fields of view in a hybrid XMR system.

PURPOSE: To validate one possible function of a real-time x-ray/MR (XMR) interface in a hybrid XMR system using x-ray images as "scouts" to prescribe the MR slices. MATERIALS AND METHODS: The registration process consists of two steps: 1) calibration, in which the system's geometric parameters are found from fiducial-based registration; and 2) application, in which the x-ray image of a target structure and the estimated geometric parameters are used to prescribe an MR slice to observe the target structure. Errors from the noise in the location of the fiducial markers, and MR gradient nonlinearity were studied. Computer simulations were used to provide guidelines for fiducial marker placement and tolerable error estimation. A least-squares-based correction method was developed to reduce errors from gradient nonlinearity. RESULTS: In simulations with both sources of errors and the correction for gradient nonlinearity, the use of 16 fiducial markers yielded a mean error of about 0.4 mm over a 7200 cm(3) volume. Phantom scans showed that the prescribed target slice hit most of the target line, and that the length visualized was improved with the least-squares correction. CONCLUSION: The use of 16 fiducial markers to co-register XMR FOVs can offer satisfactory accuracy in both simulations and experiments.

Algorithms↗

X-ray compatible radiofrequency coil for magnetic resonance imaging.

The range of RF coils that can be used in combined X-ray/MR (XMR) systems is limited because many conventional coils contain highly X-ray attenuating materials that are visible in the X-ray images and potentially obscure patient anatomy. In this study, an X-ray compatible coil design that has minimal X-ray attenuation in the field of view (FOV) of the X-ray image is presented. In this design, aluminum is used for the loop conductor and discrete elements of the coil are eliminated from the X-ray FOV. A surface coil and an abdominal phased array coil were built using the X-ray compatible design. X-ray attenuation and MR imaging properties of the coils were evaluated and compared to conventional coils. The X-ray compatible phased array coil was used to image patients during two interventional procedures in the XMR system. The X-ray compatible coils allowed for fluoroscopic X-ray image acquisition, without degradation by the coil, while maintaining excellent MR imaging qualities.

Aluminum↗

Estimation of renal extraction fraction based on postcontrast venous and arterial differential T1 values: an error analysis.

An error analysis for quantifying single kidney extraction fraction (EF) via differential T1 measurements in the renal vein (RV) and renal artery (RA) is presented. Sources of error include blood flow effects, the effect of a short repetition time (TR), and the impact of uncertainties in the T1 estimates on the final EF calculations. Blood flow effects were investigated via simulation. For a range of blood velocities in the renal vein that may be found in kidney disease, incomplete refreshment of blood between readouts results in significant errors in T1 estimation. For a .5-cm slice, 110-ms sampling interval, and T1 of 600 ms, T1 estimation to within 5% of true T1 requires an average through-plane velocity of 6.75 cm/s for parabolic flow, and 3.5 cm/s for plug flow. Improvement can be achieved by accurately estimating the fraction of blood that has not refreshed between readouts (f(old)), while the quality of the T1 estimate varies with the accuracy of f(old) estimation. Shortening of the TR was investigated using phantom and in vivo studies. T1 was estimated to within 3% of the true value on phantoms, and within 5% of the true value for flowing blood for TR = 2T1. The estimated EF is shown to be very sensitive to the difference between T(1RA) and T(1RV). To achieve 10% or 20% uncertainty in the EF estimate, T1 in the renal vein and renal artery must be estimated to within approximately 1% or 2%. Because of limitations on measurement accuracy and precision, this method appears to be impractical at this time.

Blood Flow Velocity↗

Cramér-Rao bounds for three-point decomposition of water and fat.

The noise analysis for three-point decomposition of water and fat was extended to account for the uncertainty in the field map. This generalization leads to a nonlinear estimation problem. The Crámer-Rao bound (CRB) was used to study the variance of the estimates of the magnitude, phase, and field map by computing the maximum effective number of signals averaged (NSA) for any choice of echo time shifts. The analysis shows that the noise properties of the reconstructed magnitude, phase, and field map depend not only on the choice of echo time shifts but also on the amount of fat and water in each voxel and their alignment at the echo. The choice of echo time shifts for spin-echo, spoiled gradient echo, and steady-state free precession imaging techniques were optimized using the CRB. The noise analysis for the magnitude explains rough interfaces seen clinically in the boundary of fat and water with source images obtained symmetrically about the spin-echo. It also provides a solution by choosing appropriate echo time shifts (-pi/6+pik, pi/2+pik, 7pi/6+pik), with k an integer. With this choice of echo time shifts it is possible to achieve the maximum NSA uniformly across all fat:water ratios. The optimization is also carried out for the estimation of phase and field map. These theoretical results were verified using Monte Carlo simulations with a newly developed nonlinear least-squares reconstruction algorithm that achieves the CRB.

Adipose Tissue↗

Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging.

Chemical shift based methods are often used to achieve uniform water-fat separation that is insensitive to Bo inhomogeneities. Many spin-echo (SE) or fast SE (FSE) approaches acquire three echoes shifted symmetrically about the SE, creating time-dependent phase shifts caused by water-fat chemical shift. This work demonstrates that symmetrically acquired echoes cause artifacts that degrade image quality. According to theory, the noise performance of any water-fat separation method is dependent on the proportion of water and fat within a voxel, and the position of echoes relative to the SE. To address this problem, we propose a method termed "iterative decomposition of water and fat with echo asymmetric and least-squares estimation" (IDEAL). This technique combines asymmetrically acquired echoes with an iterative least-squares decomposition algorithm to maximize noise performance. Theoretical calculations predict that the optimal echo combination occurs when the relative phase of the echoes is separated by 2pi/3, with the middle echo centered at pi/2+pik (k=any integer), i.e., (-pi/6+pik, pi/2+pik, 7pi/6+pik). Only with these echo combinations can noise performance reach the maximum possible and be independent of the proportion of water and fat. Close agreement between theoretical and experimental results obtained from an oil-water phantom was observed, demonstrating that the iterative least-squares decomposition method is an efficient estimator.

Adipose Tissue↗

Field map estimation with a region growing scheme for iterative 3-point water-fat decomposition.

Robust fat suppression techniques are required for many clinical applications. Multi-echo water-fat separation methods are relatively insensitive to B(0) field inhomogeneity compared to the fat saturation method. Estimation of this field inhomogeneity, or field map, is an essential and important step, which is well known to have ambiguity. For an iterative water-fat decomposition method recently proposed, ambiguities still exist, but are more complex in nature. They were studied by analytical expressions and simulations. To avoid convergence to incorrect field map solutions, an initial guess closer to the true field map is necessary. This can be achieved using a region growing process, which correlates the estimation among neighboring pixels. Further improvement in stability is achieved using a low-resolution reconstruction to guide the selection of the starting pixels for the region growing. The proposed method was implemented and shown to significantly improve the algorithm's immunity to field inhomogeneity.

Adipose Tissue↗

Truly hybrid X-ray/MR imaging: toward a streamlined clinical system.

RATIONALE AND OBJECTIVE: We have installed an improved X-ray/MR (XMR) truly hybrid system with higher imaging signal-to-noise ratio (SNR) and versatility than our first prototype. In our XMR design, a fixed anode X-ray fluoroscopy system is positioned between the two donut-shaped magnetic poles of a 0.5T GE Signa-SP magnet (SP-XMR). This paper describes the methods for increased compatibility between the upgraded x-ray and MR systems that have helped improve patient management. MATERIALS AND METHODS: A GE OEC 9800 system (GE OEC Salt Lake City, UT) was specially reconfigured for permitting X-ray fluoroscopy inside the interventional magnet. A higher power X-ray tube, a new permanent tube mounting system, automatic exposure control (AEC), remote controlled collimators, choice of multiple frame rates, DICOM image compatibility, magnetically shimmed X-ray detector, X-ray compatible MR coil, and better RF shielding are the highlights of the new system. A total of 23 clinical procedures have been conducted with SP-XMR guidance of which five were performed using the new system. RESULTS: The 70% increased power for fluoroscopy, and a new 6 times higher power single frame imaging mode, has improved imaging capability. The choice of multiple imaging frame rates, AEC, and collimator control allow reduction in X-ray exposure to the patient. The DICOM formatting has permitted easy transfer of clinical images over the hospital PACS network. The increased MR compatibility of the detector and the X-ray transparent MR coil has enabled faster switching between X-ray and MR imaging modes. CONCLUSION: The improvements introduced in our SP-XMR system have further streamlined X-ray/MR hybrid imaging. Additional clinical procedures could benefit from the new SP-XMR imaging.

Equipment Design↗

Time-resolved three-dimensional magnetic resonance velocity mapping of aortic flow in healthy volunteers and patients after valve-sparing aortic root replacement.

OBJECTIVE: To provide more complete characterization of ascending aortic blood flow, including vortex formation behind the valve cusps, in healthy subjects and patients after valve-sparing aortic root replacement (David reimplantation). METHODS: Time-resolved 3-dimensional magnetic resonance imaging velocity mapping was performed to analyze pulsatile blood flow by using encoded 3-directional vector fields in the thoracic aortas of 10 volunteers and 12 patients after David reimplantation using a cylindrical tube graft (T. David I) and two versions of neosinus recreation (T. David-V and T. David-V-S mod ). Aortic flow was evaluated by using 3-dimensional time-resolved particle traces and velocity vector fields reformatted onto 2-dimensional planes. Semiquantitative data were derived by using a blinded grading system (0-3: 0, none; 1, minimal; 2, medium; 3, prominent) to analyze the systolic vortex formation behind the cusps, as well as retrograde and helical flow in the ascending aorta. RESULTS: Systolic vortices were seen in both coronary sinuses of all volunteers (greater in the left sinus [2.5 +/- 0.5] than the right [1.8 +/- 0.8]) but in only 4 of 10 noncoronary sinuses (0.7 +/- 0.9). Comparable coronary vortices were detected in all operated patients. Vorticity was minimal in the noncoronary cusp in T. David-I repairs (0.7 +/- 0.7) but was prominent in T. David-V noncoronary graft pseudosinuses (1.5 +/- 0.6; P = .035). Retrograde flow (P = .001) and helicity (P = .028) were found in all patients but were not distinguishable from normal values in the T. David-V-S mod patients. CONCLUSIONS: Coronary cusp vorticity was preserved after David reimplantation, regardless of neosinus creation. Increased retrograde flow and helicity were more prominent in T. David-V patients. These novel magnetic resonance imaging methods can assess the clinical implications of altered aortic flow dynamics in patients undergoing various types of valve-sparing aortic root replacement.

Adult↗

MR-guided transjugular intrahepatic portosystemic shunt creation with use of a hybrid radiography/MR system.

PURPOSE: To evaluate the performance of a combined hybrid radiography/magnetic resonance (MR) unit to guide portal vein (PV) puncture during human transjugular intrahepatic portosystemic shunt (TIPS) creation. MATERIALS AND METHODS: Fourteen patients undergoing TIPS creation were studied during standard clinical applications. Patients were anesthetized and then positioned in an open MR unit containing a flat-panel radiographic fluoroscopic unit. With use of a combination of fluoroscopy and MR imaging, the PV was accessed and the TIPS procedure was performed. A noncovered nitinol stent or a covered stent-graft was placed in the TIPS tract. Number of punctures required, total procedure time, fluoroscopy time, procedural success rate, complications, and ultrasonographic and clinical follow-up were recorded. RESULTS: Clinical success was obtained in 13 of 14 patients. In one patient, extrahepatic puncture of the PV occurred, resulting in hemorrhage and requiring placement of a covered stent to control the bleeding. The mean number of punctures required to access the PV was 2.6 +/- 1.7, and the total procedure time was 2.5 hours +/- 0.6. Mean fluoroscopy time was 22.3 minutes +/- 5.5. Results of clinical and ultrasonographic follow-up compare favorably to previously published reports. CONCLUSION: TIPS creation with a combination hybrid radiography/MR unit is feasible and may reduce the number of needle passes required and radiation exposure, with similar overall outcomes compared with studies reported in the literature.

Alloys↗

Robust x-ray tubes for use within magnetic fields of MR scanners.

A hybrid system that combines an x-ray fluoroscopic system and a magnetic resonance (MR) system can provide physicians with the synergy of exquisite soft tissue contrast (from MR) and high temporal and spatial resolutions (from x ray), which may significantly benefit a number of image-guided interventional procedures. However, the system configuration may require the x-ray tube to be placed in a magnetic field, which can hinder the proper functioning of the x-ray tube by deflecting its electron beam. From knowledge of how the magnetic field affects the electron trajectories, we propose creating another magnetic field along the cathode-anode axis using either solenoids or permanent magnets to reduce the deflection of the electron beam for two cases: a strong and slightly misaligned field or a weak field that is arbitrary in direction. Theoretical analysis is presented and the electron beam is simulated in various external magnetic fields with a finite element modeling program. Results show that both correction schemes enhance the robustness of the x-ray tube operation in an externally applied magnetic field.

Computer-Aided Design↗

A three-dimensional reconstruction algorithm for an inverse-geometry volumetric CT system.

An inverse-geometry volumetric computed tomography (IGCT) system has been proposed capable of rapidly acquiring sufficient data to reconstruct a thick volume in one circular scan. The system uses a large-area scanned source opposite a smaller detector. The source and detector have the same extent in the axial, or slice, direction, thus providing sufficient volumetric sampling and avoiding cone-beam artifacts. This paper describes a reconstruction algorithm for the IGCT system. The algorithm first rebins the acquired data into two-dimensional (2D) parallel-ray projections at multiple tilt and azimuthal angles, followed by a 3D filtered backprojection. The rebinning step is performed by gridding the data onto a Cartesian grid in a 4D projection space. We present a new method for correcting the gridding error caused by the finite and asymmetric sampling in the neighborhood of each output grid point in the projection space. The reconstruction algorithm was implemented and tested on simulated IGCT data. Results show that the gridding correction reduces the gridding errors to below one Hounsfield unit. With this correction, the reconstruction algorithm does not introduce significant artifacts or blurring when compared to images reconstructed from simulated 2D parallel-ray projections. We also present an investigation of the noise behavior of the method which verifies that the proposed reconstruction algorithm utilizes cross-plane rays as efficiently as in-plane rays and can provide noise comparable to an in-plane parallel-ray geometry for the same number of photons. Simulations of a resolution test pattern and the modulation transfer function demonstrate that the IGCT system, using the proposed algorithm, is capable of 0.4 mm isotropic resolution. The successful implementation of the reconstruction algorithm is an important step in establishing feasibility of the IGCT system.

Algorithms↗

Stroke volume and cardiac output in juvenile elephant seals during forced dives.

The aim of this study was to examine the effect of forced diving on cardiac dynamics in a diving mammal by evaluating cardiac output and heart rate. We used MR Imaging and phase contrast flow analysis to obtain accurate flow measurements from the base of the aorta. Heart rate (fh) and cardiac output (Q) were measured before, during and after dives in four restrained juvenile northern elephant seals, Mirounga angustirostris, and stroke volume (Vs) was calculated (Vs=Q/fh). Mean Q during diving (4011+/-387 ml min(-1)) and resting (6530+/-1018 ml min(-1)) was not significantly different (paired t-test; P<0.055). Diving was accompanied by a 20% increase in Vs over the pre-dive level. Pre-dive, post-dive or diving fh was not significantly correlated with Vs during any state. Diving Vs correlated negatively with the bradycardic ratio (diving fh to pre-dive fh). In this study, the degree of bradycardia during diving was less than in previous pinniped studies, suggesting that the reduction in vagal input may contribute to the observed increase in Vs.

Animals↗