PubMed Health⌕ Search

Biomedical subjects

Norio Kato

Publications and source records attributed to Norio Kato.

6 recordsLinked to original sources

Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy.

BACKGROUND: To reduce the uncertainty of registration for lung tumors, we have developed a four-dimensional (4D) setup system using a real-time tumor-tracking radiotherapy system. METHODS AND MATERIALS: During treatment planning and daily setup in the treatment room, the trajectory of the internal fiducial marker was recorded for 1 to 2 min at the rate of 30 times per second by the real-time tumor-tracking radiotherapy system. To maximize gating efficiency, the patient's position on the treatment couch was adjusted using the 4D setup system with fine on-line remote control of the treatment couch. RESULTS: The trajectory of the marker detected in the 4D setup system was well visualized and used for daily setup. Various degrees of interfractional and intrafractional changes in the absolute amplitude and speed of the internal marker were detected. Readjustments were necessary during each treatment session, prompted by baseline shifting of the tumor position. CONCLUSION: The 4D setup system was shown to be useful for reducing the uncertainty of tumor motion and for increasing the efficiency of gated irradiation. Considering the interfractional and intrafractional changes in speed and amplitude detected in this study, intercepting radiotherapy is the safe and cost-effective method for 4D radiotherapy using real-time tracking technology.

Dose Fractionation, Radiation↗

Binary vectors and super-binary vectors.

A binary vector is a standard tool in the transformation of higher plants mediated by Agrobacterium tumefaciens. It is composed of the borders of T-DNA, multiple cloning sites, replication functions for Escherichia coli and A. tumefaciens, selectable marker genes, reporter genes, and other accessory elements that can improve the efficiency of and/or give further capability to the system. A super-binary vector carries additional virulence genes from a Ti plasmid, and exhibits very high frequency of transformation, which is valuable for recalcitrant plants such as cereals. A number of useful vectors are widely circulated. Whereas vectors with compatible selectable markers and convenient cloning sites are usually the top criteria when inserting gene fragments shorter than 15 kb, the capability of maintaining a large DNA piece is more important for consideration when introducing DNA fragments larger than 15 kb. Because no vector is perfect for every project, it is recommended that modification or construction of vectors should be made according to the objective of the experiments. Existing vectors serve as good sources of components.

Agrobacterium tumefaciens↗

Stereotactic irradiation for intracranial arteriovenous malformation using stereotactic radiosurgery or hypofractionated stereotactic radiotherapy.

PURPOSE: To investigate the appropriateness of the treatment policy of stereotactic irradiation using both hypofractionated stereotactic radiotherapy (HSRT) and stereotactic radiosurgery (SRS) for arteriovenous malformations (AVMs) located in an eloquent region or for large AVMs and using SRS alone for the other AVMs. METHODS AND MATERIALS: Included in this study were 75 AVMs in 72 patients, with a mean follow-up of 52 months. Of the 75 AVMs, 33 were located in eloquent regions or were >2.5 cm in maximal diameter and were given 25-35 Gy (mean, 32.4 Gy) in four daily fractions at a single isocenter if the patient agreed to prolonged wearing of the stereotactic frame for 5 days. The other 42 AVMs were treated with SRS at a dose of 15-25 Gy (mean, 24.1 Gy) at the isocenter. The 75 AVMs were classified according to the Spetzler-Martin grading system; 21, 23, 28, 2, and 1 AVM were Grade I, II, III, IV, V, and VI, respectively. RESULTS: The overall actuarial rate of obliteration was 43% (95% confidence interval [CI], 30-56%) at 3 years, 72% (95% CI, 58-86%) at 5 years, and 78% (95% CI, 63-93%) at 6 years. The actuarial obliteration rate at 5 years was 79% for the 42 AVMs <2.0 cm and 66% for the 33 AVMs >2 cm. The 5- and 6-year actuarial obliteration rate was 61% (95% CI, 39-83%) and 71% (95% CI, 47-95%), respectively, after HSRT and 81% (95% CI, 66-96%) and 81% (95% CI, 66-96%), respectively, after SRS; the difference was not statistically significant. Radiation-induced necrosis was observed in 4 subjects in the SRS group and 1 subject in the HSRT group. Cyst formation occurred in 3 patients in the SRS group and no patient in the HSRT group. A permanent symptomatic complication was observed in 3 cases (4.2%), and 1 of the 3 was fatal. All 3 patients were in the SRS group. The annual intracranial hemorrhage rate was 5.5-5.6% for all patients. CONCLUSION: Our treatment policy using SRS and HSRT was as effective as the policy involving SRS alone. The HSRT schedule was suggested to have a lower frequency of radiation necrosis and cyst formation than the high-dose SRS schedule. The benefit of HSRT compared with lower dose SRS has not yet been determined.

Adolescent↗

Three-dimensional conformal setup (3D-CSU) of patients using the coordinate system provided by three internal fiducial markers and two orthogonal diagnostic X-ray systems in the treatment room.

PURPOSE: To test the accuracy of a system for correcting for the rotational error of the clinical target volume (CTV) without having to reposition the patient using three fiducial markers and two orthogonal fluoroscopic images. We call this system "three-dimensional conformal setup" (3D-CSU). METHODS AND MATERIALS: Three 2.0-mm gold markers are inserted into or adjacent to the CTV. On the treatment couch, the actual positions of the three markers are calculated based on two orthogonal fluoroscopies crossing at the isocenter of the linear accelerator. Discrepancy of the actual coordinates of gravity center of three markers from its planned coordinates is calculated. Translational setup error is corrected by adjustment of the treatment couch. The rotation angles (alpha, beta, gamma) of the coordinates of the actual CTV relative to the planned CTV are calculated around the lateral (x), craniocaudal (y), and anteroposterior (z) axes of the planned CTV. The angles of the gantry head, collimator, and treatment couch of the linear accelerator are adjusted according to the rotation of the actual coordinates of the tumor in relation to the planned coordinates. We have measured the accuracy of 3D-CSU using a static cubic phantom. RESULTS: The gravity center of the phantom was corrected within 0.9 +/- 0.3 mm (mean +/- SD), 0.4 +/- 0.2 mm, and 0.6 +/- 0.2 mm for the rotation of the phantom from 0-30 degrees around the x, y, and z axes, respectively, every 5 degrees. Dose distribution was shown to be consistent with the planned dose distribution every 10 degrees of the rotation from 0-30 degrees. The mean rotational error after 3D-CSU was -0.4 +/- 0.4 (mean +/- SD), -0.2 +/- 0.4, and 0.0 +/- 0.5 degrees around the x, y, and z axis, respectively, for the rotation from 0-90 degrees. CONCLUSIONS: Phantom studies showed that 3D-CSU is useful for performing rotational correction of the target volume without correcting the position of the patient on the treatment couch. The 3D-CSU will be clinically useful for tumors in structures such as paraspinal diseases and prostate cancers not subject to large internal organ motion.

Humans↗

Impact of margin for target volume in low-dose involved field radiotherapy after induction chemotherapy for intracranial germinoma.

PURPOSE: We previously published a report stating that germinomas with elevated serum beta human chorionic gonadotropin (HCG-beta) had a poor relapse rate, but these findings have not been supported by a multi-institutional trial. The margin for initial gross tumor volume (GTV) before surgery and chemotherapy of the same materials was investigated by retrospective review. METHODS AND MATERIAL: The 27 patients reported on in the previous paper were analyzed. The two-dimensional margin from the initial GTV to 90% of the prescribed dose of 24 Gy was 2.0 cm for a solitary lesion in the protocol. This margin was measured retrospectively without knowledge of the serum HCG-beta level. The whole ventricle field was used for patients with multifocal disease and whole central nervous system field was used for disseminated disease, respectively. RESULTS: Six relapses were seen in 18 patients with solitary tumors, and were treated with the minimum margin of 1.5 cm or less to the initial GTV. Five of the 6 had initially elevated serum HCG-beta at the median of 7.4 mIU/mL, ranging from 0.7-233 mIU/mL. No relapses were seen in the 9 patients who were treated with whole ventricle or whole central nervous system field. CONCLUSIONS: An inadequate margin and elevated serum HCG-beta were equally determined to be candidates that caused the poor local control. The whole ventricle is recommended as the smallest target volume for germinoma with or without elevated HCG-beta after induction chemotherapy.

Adolescent↗

[A case of papillary adenocarcinoma of the prostate].

A case of papillary adenocarcinoma of the prostate is reported. A 73-year-old man was referred to our hospital with macrohematuria. The serum level of the PSA ranged within normal limits. Urethroscopy revealed a papillary tumor near the verumontanum. The tumor was resected transurethrally. Histopathological examination revealed adenocarcinoma with papillary growth and the tumor displayed immunoreactivity for PSA stain. Radical prostatectomy was performed. The follow-up at 11 months revealed neither local recurrence nor distant metastases.

Adenocarcinoma, Papillary↗