PubMed Health⌕ Search

Biomedical subjects

Norman Bitterlich

Publications and source records attributed to Norman Bitterlich.

5 recordsLinked to original sources

Differential diagnosis of pleural effusions by fuzzy-logic-based analysis of cytokines.

Pleural effusions can be caused by highly different underlying diseases and are characterized by complex interactions of various local and circulating cells as well as numerous soluble parameters like interleukins (IL). Knowledge about this complex network could help to indicate underlying disease. Therefore, we have investigated immunoreactive concentrations of IL-4, IL-6, IL-11, IL-15, IL-17, IL-18, and tumor necrosis factor-alpha (TNF-alpha) in pleural effusions and peripheral blood from patients with tuberculosis, bronchial carcinoma and other carcinomas as well as congestive heart failure (CHF) and pneumonias. To determine the value of cytokine measurement for differential diagnosis, statistical and fuzzy-logic methods were applied. Quantitative analysis showed high concentrations of IL-6 and IL-11 only in pleural effusions. IL-15, IL-17, IL-18 and TNF-alpha could be detected also in blood plasma. Lowest amounts were detected in CHF indicating the non-inflammatory origin of effusions. Statistical analysis did not provide evidence for diagnostic relevance of singular cytokines. Fuzzy-logic analysis was able to assign patients to the correct diseases with 80% accuracy using IL-6 and IL-15 measurement. Our results confirm the pathogenetic role of these cytokines in pleural effusions. Fuzzy-logic-based procedures may help to characterize and distinguish effusions of unknown origin even in small patient groups.

Adult↗

Increased predictive value of parameters by fuzzy logic-based multiparameter analysis.

BACKGROUND: A recent study on postoperative effusions and edema was used to demonstrate the potential of fuzzy techniques in multiparameter data analysis. In this study, more than 50 parameters of 75 patients were collected and examined for correlations between some of the parameters and the later development of complications. METHODS: We employed a rule-based fuzzy-logic system in order to combine the diagnostic values of single parameters. The advantage of fuzzy sets is that they substitute sharp cut-off values with a smooth transition from one property to another. Therefore, there is no decision of "either-or" but rather a graded assessment of "more or less", which is often more suitable for a problem. RESULTS: The fuzzy combination of parameters led to a large increase of sensitivity and specificity when compared with the best single parameter. This increase was achieved by taking a close look at the parameters. A newly created parameter, relative weight, turned out to be very powerful. CONCLUSIONS: Fuzzy techniques can increase the discriminating power of classical statistical tools. In addition, results obtained by fuzzy analysis are highly interpretable. A combination of the CLASSIF1 algorithm for the identification of the most relevant parameters, followed by fuzzy analysis, represents a powerful tool for the handling of large amounts of multiparameter data.

Adolescent↗

Fuzzy logic-based tumor-marker profiles improved sensitivity in the diagnosis of lung cancer.

BACKGROUND: The aim of this study was to improve the diagnostic efficiency of tumor markers in the diagnosis of lung cancer, by the mathematical evaluation of a tumor marker profile employing fuzzy logic modelling. METHODS: A panel of four tumor markers, i.e., carcinoembryonic antigen (CEA), cytokeratin 19 antibody (CYFRA 21-1), neuron-specific enolase (NSE), squamous cell carcinoma-related antigen (SCC) and, additionally, C-reactive protein (CRP), was measured in 175 newly diagnosed lung cancer patients with different histological types and stages. Results were compared with those in 120 control subjects, including 27 with chronic obstructive pulmonary diseases (COPD), 65 with pneumoconiosis, and 11 persons with acute inflammatory lung diseases. A classificator was developed using a fuzzy-logic rule-based system. RESULTS: Application of the fuzzy-logic rule-based system to the tumor marker values of CYFRA 21-1, NSE, and CRP yielded an increase in sensitivity of approximately 20%, i.e., 92%, compared with that of the best single marker, CYFRA 21-1(sensitivity, 72%). The corresponding specificity was 95%. The fuzzy classificator significantly improved the sensitivity of the tumor marker panel in stages I and IIIa for non-small-cell lung cancer, as well as in "limited disease" status for small-cell lung cancer. Also, the diagnosis of other stages of lung cancer was enhanced. CONCLUSION: Fuzzy-logic analysis was proven to be more powerful than the measurement of single markers alone or combinations using multiple logistic regression analysis of all markers. Therefore, fuzzy logic offers a promising diagnostic tool to improve tumor marker efficiency.

Aged↗

Fuzzy logic-based tumor marker profiles including a new marker tumor M2-PK improved sensitivity to the detection of progression in lung cancer patients.

In lung cancer patients tumor markers are used for disease monitoring. The goal of this study was to improve diagnostic efficiency in the detection of tumor progression in lung cancer patients by using fuzzy logic modeling in combination with a tumor marker panel (Tumor M2-PK, CYFRA 21-1, CEA, NSE and SCC). Thirty-three small cell lung cancers (SCLC) and 69 consecutive inoperable patients (40 squamous and 29 adenocarcinomas) were included in a prospective study. The changes of blood levels of tumor markers as well as their analysis by fuzzy logic modelling were compared to the clinical evaluation of response vs. non-response to therapy. Clinical monitoring was evaluated according to the standard criteria of the WHO. Tumor M2-PK was measured in plasma with an ELISA (ScheBo Biotech, Germany) and all other markers in sera (Roche, Germany). At a 90% specificity, the respective best single marker found the following fraction of all patients who had tumor progression clinically detected: in SCLC with NSE 52%, in adenocarcinoma with CYFRA 21-1 89% and in squamous carcinoma with SCC 65%. A fuzzy logic rule-based system employing a tumor marker panel increased the sensitivity in small cell carcinomas to 73% with the marker combination NSE/CEA and to 63% with the marker combination NSE/Tumor M2-PK, respectively. In squamous carcinomas an improvement of sensitivity is also observed using the marker combination of SCC/Tumor M2-PK (Sensitivity: 81%) or SCC/CEA (Sensitivity: 71%). By using the fuzzy logic method and the marker combination CYFRA 21-1/CEA as well as CYFRA 21-1/Tumor M2-PK, the detection of lung cancer progression was possible in all adenocarcinomas. With the fuzzy logic method and a tumor marker panel (including the new marker Tumor M2-PK), a useful diagnostic tool for the detection of progression in lung cancer patients is available.

Adenocarcinoma↗

Improved sensitivity in the diagnosis of gastro-intestinal tumors by fuzzy logic-based tumor marker profiles including the tumor M2-PK.

The aim of this study was to improve diagnostic efficiency in the detection of gastro-intestinal cancers by using fuzzy logic modeling in combination with a tumor marker panel (CEA, CA72-4, CA19-9) including Tumor M2-PK. In this prospective study histologically confirmed colorectal (n=247), esophageal (n=86) and gastric cancer (n=122) patients were investigated and compared to control (n=53) persons without any malignant diseases. Tumor M2-PK was measured in plasma with an ELISA (ScheBoBiotech, Germany); all other markers were measured in sera (Roche, Germany). At 95% specificity, tumor detection was possible by the best single marker in colorectal cancer patients in 48% (Tumor M2-PK), in gastric cancers in 61% (CA72-4) and in esophageal cancers in 56% (Tumor M2-PK). A fuzzy logic rule-based system employing a tumor marker panel increased sensitivity significantly in colorectal cancers (p<0. 001) to 63% (Tumor M2-PK and CEA), in gastric cancers (p<0.001) to 81% (Tumor M2-PK and CA 72-4) and in esophageal cancers (p<0.02) to 74% (Tumor M2-PK and CA72-4). Adding a third marker further improved the sensitivity only marginally. Fuzzy logic analysis has proven to be more powerful than measurement of single markers alone or combinations using multiple logistic regression analysis of the markers. Therefore, with the fuzzy logic method and a tumor marker panel (including Tumor M2-PK), a new diagnostic tool for the detection of gastro-intestinal cancers is available.

Aged↗