PubMed Health⌕ Search

Biomedical subjects

Nuo Gao

Publications and source records attributed to Nuo Gao.

3 recordsLinked to original sources

A new magnetic resonance electrical impedance tomography (MREIT) algorithm: the RSM-MREIT algorithm with applications to estimation of human head conductivity.

We have developed a new magnetic resonance electrical impedance tomography (MREIT) algorithm, the RSM-MREIT algorithm, for noninvasive imaging of the electrical conductivity distribution using only one component of magnetic flux density. The proposed RSM-MREIT algorithm uses the response surface methodology (RSM) algorithm for optimizing the conductivity distribution through minimizing the errors between the measured and calculated magnetic flux densities. A series of computer simulations has been conducted to assess the performance of the proposed RSM-MREIT algorithm to estimate electrical conductivity values of the scalp, the skull and the brain tissue, in a three-shell piecewise homogeneous head model. Computer simulation studies were conducted in both a spherical and realistic-geometry head model with a single variable (the brain-to-skull conductivity ratio) and three variables (the conductivity of the brain, the skull, and the scalp). The relative error between the target and estimated head conductivity values was less than 12% for both the single-variable and three-variable simulations. These promising simulation results demonstrate the feasibility of the proposed RSM-MREIT algorithm in estimating electrical conductivity values in a piecewise homogeneous head model of the human head, and suggest that the RSM-MREIT algorithm merits further investigation.

Algorithms↗

Estimation of electrical conductivity distribution within the human head from magnetic flux density measurement.

We have developed a new algorithm for magnetic resonance electrical impedance tomography (MREIT), which uses only one component of the magnetic flux density to reconstruct the electrical conductivity distribution within the body. The radial basis function (RBF) network and simplex method are used in the present approach to estimate the conductivity distribution by minimizing the errors between the 'measured' and model-predicted magnetic flux densities. Computer simulations were conducted in a realistic-geometry head model to test the feasibility of the proposed approach. Single-variable and three-variable simulations were performed to estimate the brain-skull conductivity ratio and the conductivity values of the brain, skull and scalp layers. When SNR = 15 for magnetic flux density measurements with the target skull-to-brain conductivity ratio being 1/15, the relative error (RE) between the target and estimated conductivity was 0.0737 +/- 0.0746 in the single-variable simulations. In the three-variable simulations, the RE was 0.1676 +/- 0.0317. Effects of electrode position uncertainty were also assessed by computer simulations. The present promising results suggest the feasibility of estimating important conductivity values within the head from noninvasive magnetic flux density measurements.

Algorithms↗

Use of 3-D magnetic resonance electrical impedance tomography in detecting human cerebral stroke: a simulation study.

We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm and is expanded to imaging 3-D subject conductivity distribution changes. Computer simulation studies have been conducted to evaluate the present MREIT imaging approach. Simulations of both types of cerebral stroke, hemorrhagic stroke and ischemic stroke, were performed on a four-sphere head model. Simulation results showed that the correlation coefficient (CC) and relative error (RE) between target and estimated conductivity distributions were 0.9245+/-0.0068 and 8.9997%+/-0.0084%, for hemorrhagic stroke, and 0.6748+/-0.0197 and 8.8986%+/-0.0089%, for ischemic stroke, when the SNR (signal-to-noise radio) of added GWN (Gaussian White Noise) was 40. The convergence characteristic was also evaluated according to the changes of CC and RE with different iteration numbers. The CC increases and RE decreases monotonously with the increasing number of iterations. The present simulation results show the feasibility of the proposed 3-D MREIT approach in hemorrhagic and ischemic stroke detection and suggest that the method may become a useful alternative in clinical diagnosis of acute cerebral stroke in humans.

Brain Ischemia↗