Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device.

The long-term effects of axial-flow mechanical circulatory support in humans are unclear. We report 3 cases of chronic gastrointestinal bleeding after implantation of a Jarvik 2000 axial-flow left ventricular assist device. The bleeding was refractory to aggressive management and in 2 cases resolved only after orthotopic cardiac transplantation.

Aged↗

Continuous flow pumps and total artificial hearts: management issues.

Feasibility studies are underway for new axial flow ventricular assist systems and with a total artificial heart (TAH). The axial flow pumps provide continuous flow from the left ventricle (LV) to the aorta; the TAH provides pulsatile flow to the pulmonary and systemic circulation. Understanding the differences between these systems is necessary for appropriate patient selection and management. We compared the Jarvik 2000 axial-flow pump and the AbioCor TAH. The Jarvik 2000 pump is placed in the LV with its outflow graft anastomosed to the aorta. This system is used for bridge-to-transplantation and destination therapy. The AbioCor TAH provides complete circulatory support. The AbioCor is used for destination therapy in patients expected to die in less than 30 days. Worldwide, 45 patients have received the Jarvik 2000 as a bridge to transplantation (n = 34) or destination therapy (n = 11) for an average duration of support of 132.8 days (5 to 853 days). In 30 bridge-to-transplantation cases, 14 patients (47%) have undergone heart transplantation, 5 (17%) continue to be supported with the Jarvik 2000 device, and 11 (37%) have died. Five of 7 patients supported by the AbioCor TAH survived beyond the perioperative period; 4 were ambulatory, 2 were discharged from the hospital, and 1 is at home 13 months after implantation. Anticoagulation therapy and infection management are necessary for both systems. Therapy with inotropic agents, vasoactive drugs, a pacemaker, and electrolyte normalization is necessary for Jarvik patients. AbioCor-supported patients do not require medications to support heart function. Vasoactive agents may be useful for controlling blood pressure.

Heart Failure↗

Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months.

BACKGROUND: The Jarvik 2000 axial flow left ventricular assist device (LVAD), under development for the past decade, has the potential to support patients temporarily until cardiac transplantation or as a permanent circulatory support, without the size limitations of other implantable systems. METHODS: To assess its ability to perfuse the kidneys and liver, we monitored renal and hepatic function in 10 patients who received the Jarvik 2000 LVAD as a bridge to transplantation. Left ventricular assistance was maintained for up to 214 days (> 6 months), and renal and hepatic function were monitored at least weekly. RESULTS: Renal function before LVAD implantation in these patients was normal in 7 (creatinine, < 1.5) and moderately impaired in 3 (creatinine, 1.2 to 2.0). Hepatic function was normal in 7 patients before LVAD implantation (total bilirubin< 1.2; serum glutamic-oxaloacetic transaminase (SGOT), < 40; serum glutamic-pyruvic transaminase (SGPT), < 50) and normal at the time of transplantation in all 10 patients. Of the 3 patients with abnormal hepatic function before LVAD implantation, 1 patient had also had moderate renal dysfunction. CONCLUSIONS: Despite reduced pulsatility, the Jarvik 2000 LVAD improves or maintains excellent renal and hepatic function during periods of circulatory assistance in patients awaiting transplantation.

Adult↗

Quality of life in bridge-to-transplant patients with chronic heart failure after implantation of an axial flow ventricular assist device.

Research suggests that ventricular assist devices improve quality of life for congestive heart failure patients awaiting heart transplantation. Axial flow ventricular assist devices like the Jarvik 2000 (Jarvik Heart, Inc., New York, NY) represent the newest type of ventricular assist device technology, but their effects on quality of life are not well understood. Therefore, the authors administered the Minnesota Living with Heart Failure Questionnaire to patients who had the Jarvik 2000 implanted as a bridge to heart transplantation. Patients completed the Minnesota Living with Heart Failure Questionnaire immediately before device implantation, 1 month after implantation, immediately before heart transplantation, and 1 month after transplantation. One month after implantation of the device, the nine patients who completed the study showed significant improvements in physical (p<0.008), emotional (p<0.02), and overall (p<0.008) quality of life. These improvements were maintained until the device was explanted. The authors conclude that implantation of the Jarvik 2000 ventricular assist device can substantially improve quality of life for patients awaiting heart transplantation.

Adult↗