[Effect of serum storage on the determination of triglycerides and cholesterol (author's transl)].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to O C Grillo.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
An epidemiological investigation regarding the ocular symptoms of 213 subjects working in the operating theatres of a hospital of the eastern Sicily was conducted. Information was gathered via a questionnaire designed to identify the ocular symptoms that occurred most frequently during working hours in the operating theatre. The questionnaire was administered by a specialist in Occupational Health, before any decision was made to investigate the indoor air quality. The microclimate parameters (temperature, relative humidity, number of air changes/hour, air velocity, illumination levels) of the operating theatres were also studied. The results of the epidemiological investigation showed that 154 subjects out of 213 (72.3%) reported a lack of eye comfort. The most frequently reported symptoms were fatigue (35.21%) and heaviness (34.27%), followed by burning (25.82%), redness (25.35%), lacrimation (17.84%), itching (2%), blinking (20%), foreign body sensation (19%) and photophobia (10%). The study of the indoor climate of the operating theatres showed that the number of air changes/hour and illumination level were not consistent with those recommended by the Italian Regulatory Authority. Others parameters were considered to be satisfactory. The Authors conclude that the low illumination level may be responsible for the high percentage of subjects suffering from eye fatigue and heaviness. The ineffective rate of room air exchange, possibly interacting with chemicals and aerosols, is thought to be responsible for the other ocular symptoms experienced by the workers. The present study suggests that the operating theatre environment might be a cause of the ocular discomfort often complained of by health care workers. Further studies are needed in this area.
Explore the source record for details and available documents.
The results of a research, in winter and spring, on the microclimatic parameters and lighting in eighteen classrooms of primary schools in the town of Messina, are exposed. In a significant number of classrooms values of temperature and relative humidity are registered not in accordance with Italian standards. Thermal indices (PMV and PPD) showed, in both seasons, discomfort conditions in many rooms. A percentage of dissatisfied persons, significantly higher the 10% (56.8% in winter and 70.3% in spring), has been obtained. We used, also, a questionnaire modified by Fanger to evaluate the thermal subjective sensations of the students. The results point out that the thermal subjective sensations expressed by the students are often in disagreement with the Fanger thermal comfort indices obtained by instrument. The authors believe that the Fanger's indices do not reflect the effective environmental conditions.
The authors have carried a study on the knowledge of disinfection practices and the behaviour in operating room in order to control and prevent nosocomial infections. It is necessary for high percent of head nurses and nurses to have guidelines for the disinfection/sterilization procedures with the aim to avoid infections, but a large number of subjects don't know the correct procedures. The knowledge of a correct behaviour in the operating room is greater, although many of nursing staff don't wear the overshoes and the protective glasses. The statistical analysis show that nurses and the subjects with high degree have a greater knowledge of problems. It is important the planning of training and retraining courses directed to the improvement of technical knowledge and behaviour.
The objective of the present research was to evaluate the effect of environmental parameters (temperature, air velocity, relative humidity, illumination level, cubature) on ocular symptoms (tiredness, tearing, redness, blinking, itching, burning, photophobia, foreign body sensation, and heaviness) in a group of 54 male Video Display Terminal (VDT) workers. The subjects were employed in a public office placed in Messina and naturally ventilated; the investigation was performed in Spring time. Information about the ocular symptoms, occurring during the workshift, were gathered through a questionnaire; environmental measurements were performed by a data collector LSI. The results showed that 43 subjects out of 54 (79%) reported a lack of eye comfort; in addition the illumination level, temperature and air velocity were not consistent with those suggested by the Italian Regulatory Authority. A significant correlation between illumination level, temperature, air velocity and eye discomfort (tearing, heaviness, blinking, photophobia itching, respectively) was found. The Authors conclude that the inadequate environmental condition, possibility in interaction with the indoor chemical contaminants and the workload at VDT, may be responsible for the irritative eye symptoms complained by VDT-workers at workplace.
Most pollution of drinking water is caused by inadequacy of the uptake and distribution systems, by insufficient upkeep of the sewage system and by defects or breaks in the disinfection processes. This may be the cause of waterborne epidemic outbreaks and therefore it is necessary carry out routine controls by simple and rapid tests for the detection of intestinal organisms. In the light of minor hepatitis A epidemics occurred in the town of Messina, we have carried out a study to determine the drinking water quality. To this end, in addition to the traditional tests recommended by CEE and required by the 8/2/1985 DPCM (37 degrees C and 20 degrees C viable count, total and faecal coliforms and faecal streptococci), we have carried out P. aeruginosa, coliphages and gram-negative endotoxins tests, in 74 water samples drawn on way in and way out of the tanks and along the piping system. Only 12.5% of the sixteen water samples drawn on way in (before disinfection system) was in compliance with the law. 75% of these samples showed positivity for faecal streptococci. The water quality was lower in the fourteen water samples drawn on way out of the tanks (7.1% was in compliance with the law). The percent of positivity along the piping system for total and faecal coliforms and for faecal streptococci was 34.1, 15.9 and 59.1 respectively. Coliphages were always absent. P. aeruginosa was almost always present in way in water (93.7%). Moreover this microorganism was recovered in 85.7% of the samples drawn on the way out and in 77.3% along the piping system. In the same drawing places endotoxins were present at high percentage (100%, 85.7% and 90.9%). These values come from high test sensitivity and poor water quality. Finally we have pointed out the importance of all the parameters examined. The significance of coliform bacteria is known, but we consider very important, as organisms indicative of pollution, the enterococci, since they P. aeruginosa may survive long time in fresh water though it is not autoctone, but, in general, of faecal origin. Several soluble antigens of this microorganism as well as enterococci show positive LAL tests (1-5-6). The endotoxin content in fresh water reflects the degree of bacterial contamination. We believe, therefore, it is needed to fix an upper limit to endotoxins in drinking water. Coliphages concentrations could be correlated with enteric virus concentrations but the ratio of coliforms to coliphages is about 100:1. Therefore this indicator of viral pollution is helpful only for highly polluted surface waters.
The Authors have carried out a research on the purpose of explain the action of a typhoid vaccines prepared on a semi-synthetic medium, which in preliminary tests on mice and men evinced good immunizing power. The tests now performed demonstrate that an acellular filtrate of the vaccine (obtained from 24 h old culture) showed have the characteristics of an exotoxin and developes a strong immunizing power.