PubMed Health⌕ Search

Biomedical subjects

O Catapano

Publications and source records attributed to O Catapano.

3 recordsLinked to original sources

[Echocardiographic study of left ventricular function using automated border detection in normal subjects].

BACKGROUND: Two-dimensional (2D) echocardiographic automated border detection (ABD) can provide on-line measurement of left ventricular cavity area and fractional area change. However, this new quantitative method has not been extensively validated. METHODS: Values of manually traced areas on 2D-echo images were compared with those obtained from ABD in 34 consecutive normal subjects (age 16-65 years). Only subjects with more than 70% of endocardial border circumferences clearly seen in both selected imaging planes were included in the study. We evaluated left ventricular end-diastolic and end-systolic area, and fractional area change obtained from mid-left ventricular short axis and apical 4-chamber view. Left ventricular volumes (area/length method) and ejection fraction were manually calculated off-line from apical 4-chamber view. RESULTS: From the short axis view, left ventricular cavity area measurements with ABD were obtained in 85% of subjects. The values closely correlated with off-line measurements: end-diastolic area 15.6 +/- 3.1 vs 14.8 +/- 3.3 cm2, r = 0.88 SEE = 1.58; end-systolic area 7.2 +/- 1.7 vs 6.7 +/- 1.7 cm2, r = 0.88 SEE = 0.80. A good correlation was also found for the apical 4-chamber view; end-diastolic area 25.9 +/- 5.9 vs 25.3 +/- 5.5 cm2, r = 0.97 SEE = 1.36; end-systolic area 16.3 +/- 4.1 vs 15.0 +/- 3.8 cm2, r = 0.92 SEE = 1.51. In this view ABD measurements were obtained in 79% of subjects. A significant correlation was also found between the end-diastolic volume and short axis (r = 0.54, SEE = 2.63; p 0.003) and apical 4-chamber (r = 0.66, SEE = 4.51; p = 0.0002) ABD diastolic area. Similarly, the end-systolic volume was significantly correlated with short axis (r = 0.57, SEE = 1.42; p = 0.001) and apical 4-chamber (r = 0.55, SEE = 3.54; p = 0.003) ABD systolic area. However, the on-line fractional area change correlated with off-line ejection fraction better from short axis view: (r = 0.72 SEE = 3.52) than from apical 4-chamber view (r = 0.45 SEE = 6.84). CONCLUSIONS: These data indicate that: 1) left ventricular areas measured by ABD correlate well with manually measured areas and volumes; 2) short axis ABD fractional area change may be a reliable substitute of off-line manually traced ejection fraction in normal subjects.

Adolescent↗

[Evaluation of atrial septum aneurysm with transesophageal echocardiography in cardioembolic cerebral ischemia].

The prevalence and characteristics of atrial septal aneurysm were identified by transesophageal echocardiography (TEE) in a multicenter prospective study. One hundred and seventy-seven consecutive patients were evaluated in 2 years and 2 groups were compared: Group 1, 51 patients with documented cerebral ischemia event; Group 2, 126 patients affected by cardiac disease referred for other reasons. Group 1 included patients selected among 352 patients admitted to the Neurological and Geriatric Division of our Hospital in the period of this study. Patients with stroke-related carotid lesions and patients with a negative TC scan were excluded from this study. Atrial septal aneurysm was identified in 15 patients: 8 in Group 1 (16%), and 7 in Group 2 (5%), with a significant statistical difference between the groups (p = 0.02). All patients with atrial septal aneurysm underwent before TEE transthoracic echocardiography, leading to a correct diagnosis in 10 of 15 cases (66%); all patients underwent 24-hours ECG monitoring. A right to left shunt was detected by contrast echocardiography in 9 patients, 6 in Group 1 and 3 in Group 2, (NS). A more pronounced shunt was evident in Group 1. There was no difference between the 2 groups with regard to associated cardiac disease, arrhythmias and type of atrial septal aneurysm. The thickness of the septum was greater in Group 1, with significant statistical difference (p = 0.002). It is concluded that atrial septal aneurysm, diagnosed by TEE, is a potential source of embolic events.

Adult↗