PubMed Health⌕ Search

Biomedical subjects

O Ergene

Publications and source records attributed to O Ergene.

13 recordsLinked to original sources

Must antidysrhythmic agents be given to all patients with new-onset atrial fibrillation?

We investigated the spontaneous conversion rate of new-onset atrial fibrillation (AF) in emergency department patients and the recurrence rate of AF during a 1 month follow-up period. Sixty-six consecutive hemodynamically stable patients presenting to a university hospital emergency department with new-onset atrial fibrillation (less than 72 hours duration) comprised the study population. Patients were initially monitored for 8 hours and observed for spontaneous conversion of AF to sinus rhythm. If conversion did not occur in the first 8 hours, an oral loading dose (600 mg) of propafenone was given, and patients were observed for an additional 8 hours. All patients were reevaluated at 24 hours and at 1 month. The spontaneous conversion rate in patients presenting within 6 hours of AF onset during the initial 8-hour observation period was 71%. The spontaneous conversion rate for all patients during the initial observation period was 53%. The conversion rates between patients presenting "early" (less than 6 hours) and "late" (7-72 hours) were significantly different (P < 0.001). Many patients with new-onset AF, especially those with atrial fibrillation duration less than 6 hours, may need observation only, rather than immediate intervention, to treat their dysrhythmia.

Administration, Oral↗

Catheter-induced vasospasm in the right external iliac and femoral arteries during a cardiac diagnostic procedure.

Catheter-induced vasospasm of small caliber arteries, such as the coronary arteries, is frequently observed during cardiac catheterization, but obstruction of the large caliber arteries has not previously been reported. Here we present two cases in which femoral and external iliac arteries were totally obstructed due to spasm during diagnostic coronary angiography.

Angina, Unstable↗

Use of intraventricular dispersion of the peak diastolic flow velocity as a marker of left ventricular diastolic dysfunction in patients with atrial fibrillation.

The aim of this study was to evaluate the use of intraventricular dispersion of the peak diastolic flow velocity as a marker of left ventricular diastolic dysfunction in patients with atrial fibrillation. Regional diastolic flow velocity patterns at 1, 2, and 3 cm away from the mitral tip toward the apex were simultaneously recorded with the mitral flow velocity pattern by using pulsed Doppler echocardiography in 24 patients with atrial fibrillation before electrical or medical cardioversion. Echocardiographic examination was repeated after 10 to 30 days (ie, at the time of recovery of left atrial mechanical functions) after cardioversion of atrial fibrillation in all patients. Thirteen patients were found to have diastolic dysfunction; the remaining 11 patients with a normal E/A ratio constituted the control group. Afterward, the data recorded before the cardioversion were analyzed for each patient. In subjects with normal diastolic function, the peak diastolic flow velocity (PDFV) at the mitral tips also was maintained at the positions 1 to 3 cm away from the tip in the left ventricular cavity (PDFV at the mitral tips: 0.84 m/s, PDFV at 3 cm: 0.85 m/s; P =.34). In contrast, the regional PDFV progressively decreased toward the apex in patients with diastolic dysfunction (PDFV at the mitral tips: 0.82 m/s, PDFV at 3 cm: 0.63 m/s; P =.0004). Only 77% of the initial velocity was maintained at 3 cm away from the mitral tips in patients with diastolic dysfunction, whereas almost 100% of the initial velocity was preserved in patients with normal diastolic function (P <.001). These findings suggest that the assessment of the intraventricular decrease in mitral PDFV may be used as a reliable marker of diastolic dysfunction in patients with atrial fibrillation.

Atrial Fibrillation↗

Infusion versus bolus injection of Tc-99m tetrofosmin in the identification of viable myocardium.

In this report, a patient with 100% RCA stenosis and prominent collaterals, in which TI-201 rest/redistribution and Tc-99m tetrofosmin infusion imaging findings were compatible with viable myocardium in contrast to Tc-99m tetrofosmin bolus imaging is presented. Viability was confirmed with improvement of wall motion and perfusion 3 months after revascularization. Infusion of Tc-99m tetrofosmin rather than a bolus injection may be a more reliable technique in the identification of severely ischemic but viable myocardium.

Coronary Disease↗

Compliant vs non-compliant balloons. A prospective randomized study.

In this prospective randomized trial we explored the possibility of different procedural outcomes with regard to compliant (polyolefin copolymer (POC)), and non-compliant (polyethylene terapthelate (PET)) balloon materials commonly used during percutaneous transluminal coronary angioplasty (PTCA). For this purpose, 51 female and 149 male (total 200) patients were randomized to 100 compliant and 100 non-compliant balloons. Only single lesions were included in the study and patients who had PTCA for more than one lesion in different segments at different sessions were each entered separately (there were actually 49 female and 143 male patients). PTCA procedures were performed in conjunction with quantitative coronary angiographic techniques and the films were reviewed by two investigators in a blinded fashion. Statistical analysis for various procedural end-points were performed by non-paired Student t test with statistical significance being p < 0.05. There were no differences in demographic and clinical characteristics between groups. Lesion characteristics of both groups were exactly matching for vessel size, balloon size, balloon vessel ratio, minimal luminal diameter and percent stenosis of the index lesion. Similarly, minimal residual diameter, percent residual stenosis, net gain, densitometric net area gain, and maximum pressure (2.2 +/- 5 mm vs 2.1 +/- 0.6 mm, 18 +/- 17% vs 23 +/- 15%, 0.8 +/- 0.5 mm vs 0.8 +/- 0.6 mm, 48 +/- 25% vs 48 +/- 26%, 7.3 +/- 2 atm. vs 6.8 +/- 3 atm., respectively) values were not statistically different between compliant and non-compliant balloon groups. Major in-hospital complications, dissections caused by the study balloon (mostly type A and B), crossover and bail-out procedures (5 vs 3, 34 vs 32, 4 vs 3, 13 vs 14, respectively) were similar for both compliant and non-compliant balloon groups. Study balloon success rate (defined as < 50% residual stenosis or > 20% net gain in the absence of major in-hospital complications, crossovers and bail-outs) and overall procedural success rate (80% vs 74%, 90% vs 85%) were not statistically different for compliant and non-compliant balloons. In conclusion, we did not observe any statistically significant difference between compliant and non-compliant balloons in terms of immediate procedural results.

Aged↗

Directional coronary atherectomy versus coronary angioplasty in vessels larger than 3 mm in diameter.

It has been proposed that directional coronary atherectomy (DCA) should be an intervention of choice in larger vessels as one can achieve a greater minimal luminal diameter with DCA than with percutaneous transluminal coronary angioplasty (PTCA). This in turn should translate into a higher success rate and may even reduce the restenosis rate. The aim of this study was to compare DCA versus PTCA in vessels > 3 mm in diameter. One hundred fifty consecutive patients who met the inclusion criteria and had DCA were compared to 150 similarly selected PTCA patients. PTCA patients were selected from the era immediately preceding the advent of DCA so that selections bias could be excluded. All patients with ostial lesions, restenosis, vessels < 3 mm in diameter, and vessels with more than two significant lesions were excluded. Distal segments and circumflex cases were excluded as they formed a small subsegment. Both groups were similar in terms of demographic, clinical and angiographic variables. Quantitative analysis showed that the initial net gain was significantly greater in the DCA group than in the PTCA group (2.36 +/- 0.8 mm vs. 1.78 +/- 0.7 mm; p < 0.05). Residual stenosis was 11% with DCA compared to 33% with PTCA (p < 0.05). Despite these improved anatomical results the procedural success rates were similar (91.5% vs 84%). Major in hospital complications (death, acute occlusion, MI, emergency CABG, re-do) were higher in the DCA group than in the PTCA group (12% vs 6%). Clinical follow-up on 276 patients (150 DCA vs 126 PTCA) showed a 6 month clinical restenosis rate of 18% vs 28%, respectively. The incidence of re-do in 24 hours for acute occlusion was 6% for DCA and 1% for PTCA. In large-sized vessels DCA results in a lower restenosis rate. However, despite a lower incidence of residual stenosis, the complication rate tends to be higher with DCA (p < 0.05).

Aged↗

Comparison of Angiographic and Clinical Outcome After Cutting Balloon and Conventional Balloon Angioplasty in Vessels Smaller than 3 mm in Diameter: A Randomized Trial.

OBJECTIVES: The purpose of the study was to evaluate and compare the immediate and six month follow-up angiographic and clinical outcome of cutting balloon angioplasty and conventional balloon angioplasty in small vessels (less than 3 mm in diameter). METHODS AND RESULTS: Between August 1995 and August 1996 a total of 71 eligible symptomatic patients with angiographically proven significant lesions in their coronary arteries smaller than 3 mm and requiring revascularization, were randomized to receive treatment by either cutting balloon angioplasty (CB) or conventional balloon angioplasty (BA). ÒStand-aloneÓ CB was performed on 51 lesions in 36 patients and BA on 47 lesions in 35 patients. Basic angiographic and clinical characteristics were similar in both groups. The overall procedural success rates for CB and BA groups were 92% and 97%, respectively. The immediate post-procedural minimal luminal diameter, residual stenosis and acute gain were similar in the CB and BA cohorts (1.93 +/- 0.36 mm, 24 +/- 12%, 1.18 +/- 0.45 mm vs. 2.01 +/- 0.34 mm, 22 +/- 9%, 1.26 +/- 0.35 mm, respectively). Total dissection rate and C-F dissections were fewer in the CB group (37%, 6% vs. 51%, 19%, respectively, p < 0.05). Six month follow-up angiographic restenosis rate was lower in the CB group (27% vs. 47%, p < 0.05). We also detected a significant difference of total number of all events at nine month clinical follow up (28% vs. 51%, p < 0.05). CONCLUSION: CB angioplasty can be performed with a comparable success rate to conventional BA in small vessels. Fewer bail-out procedures are needed as CB causes fewer and less severe dissections. There is also a significant reduction in six month restenosis rate. We suggest that CB might be a better option for revascularizing vessels smaller than 3 mm in diameter which are inherently more prone to immediate complications and late restenosis with BA.

Journal Article↗

Predictors of success in the conversion of new-onset atrial fibrillation using oral propafenone.

We have investigated the relationship of clinical variables to successful cardioversion of atrial fibrillation (AF) to sinus rhythm using an oral loading dose of propafenone. Fifty consecutive patients with recent onset (< 72 hours) atrial fibrillation of various aetiologies were included in the study cohort. All patients were given the study medication while in the emergency department and then monitored for 8 hours. All patients converting to sinus rhythm (39 out of 50, 78%) were discharged and re-evaluated at 24 hours and 30 days. We investigated the effect of clinical factors such as age, sex, presence of hypertension (HT), chronic obstructive lung disease (COPD), diabetes mellitus (DM), mitral stenosis (MS), congestive heart failure (CHF), coronary artery disease (CAD) and the duration of atrial fibrillation on conversion to sinus rhythm. Of these factors, univariate and multivariate analysis showed that only the duration of atrial fibrillation was a significant predictor of conversion (p = 0.002). Our results suggest that most patients with new-onset AF can be converted successfully to sinus rhythm with a low incidence of adverse reactions using oral propafenone in the emergency department.

Acute Disease↗

Correlation between serum lipoprotein(a) and angiographic coronary artery disease in non-insulin-dependent diabetes mellitus.

OBJECTIVES: To examine the impact of diabetic state on the concentrations of lipoprotein(a) [Lp(a)] in patients with non-insulin-dependent diabetes mellitus (NIDDM) and the correlation between angiographic coronary artery disease (CAD) and serum Lp(a) concentrations in NIDDM. DESIGN: In this cross-sectional study of 26 patients with NIDDM and 19 nondiabetic sex- and age-matched patients who underwent coronary angiography. CAD was assessed visually using coronary artery score (CAS), and plasma Lp(a) was measured by an enzyme-linked immunosorbent assay. SETTING: The study was performed in an internal medicine clinic at a university hospital. SUBJECTS: Twenty-six age- and sex-matched patients with NIDDM and 19 control patients without diabetes. RESULTS: There was no significant difference between the Lp(a) concentrations of patients with NIDDM and nondiabetic subjects (P > 0.05). When patients with NIDDM were stratified by absence or presence of CAD, patients with CAD had higher levels of Lp(a) (P < 0.05). However, there was no significant correlation between the concentrations of Lp(a) and CAS (P > 0.05). CONCLUSIONS: Diabetic state does not have any impact on Lp(a) concentrations. Lp(a) excess seems to be atherogenic in patients with NIDDM as shown in nondiabetic patients in previous studies. Although diabetic patients with CAD have higher Lp(a) concentrations than the diabetic patients without CAD, Lp(a) levels were not correlated with CAS.

Coronary Angiography↗

Sublingual nitrate plus 99Tcm-tetrofosmin infusion in the detection of severely ischaemic but viable myocardium: a comparative study with stress, redistribution, reinjection and late redistribution 201Tl imaging.

To investigate the role of sublingual nitrate plus 99Tcm-tetrofosmin infusion in the detection of severely ischaemic but viable myocardium, we selected 25 patients with coronary artery disease who had at least one fixed segmental defect during conventional stress-redistribution (ST-RD) 201Tl single photon emission tomographic (SPET) imaging. Reinjection (RI) and 24 h late redistribution (LRD) imaging were also performed. Within a week of 201Tl imaging, one-day rest-stress (R-ST) 99Tcm-tetrofosmin SPET was performed with the same stress levels. The following day, 99Tcm-tetrofosmin was infused over 1 h immediately after sublingual nitrate administration and SPET images (N + Inf) were acquired. Of 100 fixed defects on R-ST 99Tcm-tetrofosmin imaging, 15 were reversible on N + Inf 99Tcm-tetrofosmin imaging. There was 91% concordance between ST-RD/RI/LRD 201Tl and R-ST/N + Inf 99Tcm-tetrofosmin imaging regarding reversibility. We conclude that N + Inf 99Tcm-tetrofosmin imaging may be clinically useful in the detection of severely ischaemic but viable myocardium.

Administration, Sublingual↗

Non-invasive diagnosis and management of coronary arteriovenous fistula. A case report.

Coronary arteriovenous fistulas are rare anomalies resulting in abnormal communication between the coronary artery and any chamber of the heart. An asymptomatic patient was referred for evaluation of her murmur. Two-dimensional and color Doppler echocardiographic evaluation revealed an enlarged left main coronary artery. A retrograde, eccentric small jet was found within the right ventricular outflow tract at the pulmonary artery valvular level allowing us to detect the entrance site of the fistula. The diagnosis was confirmed by cardiac catheterization and angiocardiography. Although our case was asymptomatic, the decision to perform cardiac surgery was made because of the aneurysmatic appearance of the left coronary artery. In our opinion, visualization of coronary arteries by two-dimensional echocardiography, together with additional information obtained from the Doppler examination, provides an excellent technique for the noninvasive diagnosis of coronary artery fistula.

Arteriovenous Fistula↗