Baseline hemodynamic and echocardiographic indices in anesthetized calves.

The experimental calf model is used to assess mechanical circulatory support devices and prosthetic heart valves. Baseline indices of cardiac function have been established for the normal awake calf but not for the anesthetized calf. Therefore, we gathered hemodynamic and echocardiographic data from 16 healthy anesthetized calves (mean age, 189.0 +/- 87.0 days; mean body weight, 106.9 +/- 32.3 kg) by cardiac catheterization and noninvasive echocardiography, respectively. Baseline hemodynamic data included heart rate (65 +/- 12 beats per minute), mean aortic pressure (113.5 +/- 17.4 mm Hg), left ventricular end-diastolic pressure (16.3 +/- 38.9 mm Hg), and mean pulmonary artery pressure (21.7 +/- 8.3 mm Hg). Baseline two-dimensional echocardiographic data included left ventricular systolic dimension (3.5 +/- 0.7 cm), left ventricular diastolic dimension (5.6 +/- 0.8 cm), end-systolic intraventricular septal thickness (1.7 +/- 0.2 cm), end-diastolic intraventricular septal thickness (1.2 +/- 0.2 cm), ejection fraction (63 +/- 10%), and fractional shortening (37 +/- 10%). Doppler echocardiography revealed a maximum aortic valve velocity of 0.9 +/- 0.5 m/s and a cardiac index of 3.7 +/- 1.1 L/minute/m2. The collected baseline data will be useful in assessing prosthetic heart valves, cardiac assist pumps, new cannulation techniques, and robotics applications in the anesthetized calf model and in developing calf models of various cardiovascular diseases.

Anesthetics, Dissociative↗

Thrombogenicity of mechanical aortic valves in an animal model: site specific testing is crucial.

We evaluated a new trileaflet prosthesis and a control bileaflet prosthesis in the mitral and aortic positions in 27 calves. The prototype trileaflet valve (TV1) functioned satisfactorily in the mitral position (TV1m, n = 7) but later yielded thrombogenic complications in the aortic position (TV1a, n = 4). The valve was redesigned (TV2) and retested in the mitral (TV2m n = 4) and aortic (TV2a, n = 5) positions, along with control valves (Cm, n = 4; Ca, n = 3). At necropsy, the valves were graded on a scale of 0 (no visible thrombi) to 4 (thrombi greater than 5 mm and/or obstructed leaflets). The TV1m, TV2m, and Cm animals, respectively, had implant durations of 215+/-112, 140+/-63, and 159+/-89 days and thrombus grades of 0.71+/-0.76, 0.33+/-0.58, and 1.50+/-0.58. The TV1a, TV2a, and Ca animals had implant durations of 18+/-12, 159+/-61, and 108+/-62 days and thrombus grades of 2.75+/-1.00, 0.50+/-0.58, and 0.67+/-0.58 (p < .005; TV2a vs. TV1a). Three TV1a calves died early of valve related complications. A design irregularity, undetected in the mitral position but revealed in the aortic position, caused a high early mortality in the TV1a animals. Redesigning the prosthesis eliminated valve related mortality and significantly reduced the thrombus grade. Because satisfactory performance in the mitral position does not guarantee safety or efficacy in the aortic position, site specific preclinical testing is crucial for mechanical heart valves.

Animals↗

Biventricular support with the Jarvik 2000 ventricular assist device in a calf model of pulmonary hypertension.

The Jarvik 2000 ventricular assist device (VAD) is clinically efficacious for treating end-stage left ventricular failure. Because simultaneous right ventricular support is also occasionally necessary, we developed a biventricular Jarvik 2000 technique and tested it in a calf model. One VAD was implanted in the left ventricle with outflow-graft anastomosis to the descending aorta. The other VAD was implanted in the right ventricle with outflow-graft anastomosis to the pulmonary artery. Throughout the 30 day study, hemodynamic values were continuously monitored. On day 30, both pumps were evaluated at different speeds, under various hemodynamic conditions. By gradually occluding the pulmonary artery proximally or distally, we simulated varying degrees of high pulmonary vascular resistance, right ventricular hypertension, global heart failure, or ventricular fibrillation. The two VADs maintained biventricular support even during pulmonary artery occlusion and ventricular fibrillation, yielding a cardiac output of 3-11 L/min, left ventricular end-diastolic pressure of 11-24 mm Hg, and central venous pressure of 9-25 mm Hg. End-organ function was unimpaired, and no major adverse events occurred. The dual VADs offered safe, effective biventricular assistance in the calf. Additional studies are needed to assess the effects of lowered pulse pressure upon the pulmonary circulation and to develop a single pump speed controller.

Animals↗

Evaluation of a new cardiac recovery system in a bovine model of volume overload heart failure.

We evaluated the short-term hemodynamic efficacy of the Cancion cardiac recovery system (CRS) in a bovine model of volume overload heart failure. We created severe mitral regurgitation (MR) by disrupting the mitral chordae tendineae of two calves, which were allowed to survive for 13 and 11 months. Four hours before we killed the calves, we introduced the CRS, which maintained flows of 1.2 L/min. Hemodynamic data were recorded before and after MR creation and CRS initiation. Left ventriculography was performed at those same intervals and 4 hours after CRS initiation. After chordal disruption, the left ventricular end-diastolic pressure (LVEDP) increased from 14 to 23 mm Hg in calf 1 and 15 to 27 mm Hg in calf 2. After 4 hours of CRS support, the LVEDP decreased from 23 to 8 mm Hg (calf 1) and 27 to 14 mm Hg (calf 2); dP/dt increased from 1,373 to 2,900 mm Hg/s (calf 1) and 1,068 to 2,384 mm Hg/s (calf 2). MR decreased from 3+ to 1 in calf 2 but could not be determined in calf 1. In this bovine model of volume overload heart failure, the CRS unloaded the left ventricle and reduced the afterload. Future trials will determine the pump's ability to treat congestive heart failure.

Animals↗

Effect of pump flow mode of novel left ventricular assist device upon end organ perfusion in dogs with doxorubicin induced heart failure.

End organ effects of nonpulsatile (NP) and pulsatile (P) left ventricular assist device (LVAD) flow were compared in a canine model of doxorubicin-induced heart failure. After heart failure induction, a prototype bimodal LVAD was implanted. Hemodynamics, cardiac dimensions, and myocardial metabolism were monitored with the LVAD off (baseline) and on (in NP and P modes at 70% or 100% power). End organ perfusion was assessed by colored microsphere analysis. Seven dogs were used: two died before pump implantation and were excluded from analysis, and the remaining five survived to study termination. At 70% NP, ascending aortic flow and myocardial oxygen consumption (MVO2) decreased significantly. At 100% NP, LV dimensions decreased, aortic systolic, pulse, and LV pressures decreased but not significantly, and ascending aorta flow reversed. At 100% NP, coronary blood flow, MVO2, and LV free wall subepicardial and subendocardial blood flows decreased significantly. However, as NP support increased, the subepicardial/subendocardial blood flow ratio remained near baseline. At 100% NP, right ventricular perfusion decreased but not significantly, cerebral perfusion decreased significantly, and renal perfusion stayed constant. P mode results were similar, except that ascending aorta flow decreased significantly at 100% P instead of reversing as at 100% NP. These results suggest that end organ perfusion is not differentially affected by LVAD flow mode during chronic heart failure.

Animals↗

The effect of intermittent low speed mode upon aortic valve opening in calves supported with a Jarvik 2000 axial flow device.

We assessed the effects of an axial flow left ventricular assist device (LVAD) upon aortic valve opening, pump outflow, and biologic and hematologic parameters when operated in intermittent low speed (ILS) mode. An ILS controller equipped Jarvik 2000 LVAD was implanted in six calves. Pump speed was maintained at 10,000 rpm, and pump outflow was measured throughout the study period (71 +/- 6 days [mean +/- SD]). Hematologic and biochemical parameters were analyzed daily for the first 10 days, weekly for the first month, and biweekly thereafter to monitor for kidney or liver dysfunction, hemolysis, bleeding, or infection. Before study termination, esmolol hydrochloride was infused to induce low cardiac output and totally impair aortic valve opening. Radiopaque cineaortography was performed over 30 second intervals (10 seconds before, 10 seconds during, and 10 seconds immediately after ILS controller activation) to assess the effect of ILS mode upon aortic valve opening. After study termination, major end organs and the major vascular tree were removed and examined macroscopically and histologically for thrombus formation and infarction; the aortic valve was examined for thickening and fusion. All pumps were explanted and examined for thrombus formation. All six calves recovered without surgical or mechanical complications. Hematologic and biochemical parameters did not change significantly between baseline and study termination. The aortic valve successfully opened when ILS mode was activated, even under low cardiac output conditions. No thrombus was detected in the major end organs and vascular tree, except for some small renal infarcts in three calves that did not affect renal function. These results indicate that operating an axial flow LVAD in ILS mode allows aortic valve opening and aortic root washout.

Animals↗

Total heart replacement with dual centrifugal ventricular assist devices.

In an ovine feasibility study, we implanted two HeartMate-III centrifugal ventricular assist devices (VADs) for total heart replacement. With cardiopulmonary bypass support, both ventricles were transected at the atrioventricular groove, preserving a rim of ventricular tissue. The atrioventricular valves were excised, and the aorta and pulmonary artery were transected above the ventriculoarterial valves. An interatrial septal window was created by excising the foramen ovale. The VADs' sewing rings were attached to the left and right ventricular remnants, respectively. Outflow grafts were anastomosed to the aorta and pulmonary artery. The left VAD operated continuously at 4,500 rpm. Right VAD speed increased from 2,000 to 4,500 rpm in 500 rpm increments. Outflow graft flow, pressure, oxygen saturation, and shunt direction were recorded. The pulmonary artery to aortic ratio of flow and pressure increased from 0.26 and 0.15 (at 2,000 rpm) to 1.21 and 0.53, respectively (at 4,500 rpm). The interatrial shunt, which was right to left at lower right VAD speeds, progressed to bidirectional, then to left dominant as right VAD speed increased. Outflow-graft oxygen saturation was reflective of the shunt direction. In this acute experiment, total heart replacement with continuous flow VADs satisfactorily balanced left and right ventricular flows and preserved the physiologic circulatory response.

Animals↗

Total heart replacement using dual intracorporeal continuous-flow pumps in a chronic bovine model: a feasibility study.

Continuous-flow pumps are small, simple, and respond physiologically to input variations, making them potentially ideal for total heart replacement. However, the physiological effects of complete pulseless flow during long-term circulatory support without a cardiac interface or with complete cardiac exclusion have not been well studied. We evaluated the feasibility of dual continuous-flow pumps as a total artificial heart (TAH) in a chronic bovine model. Both ventricles of a 6-month-old Corriente crossbred calf were excised and sewing rings attached to the reinforced atrioventricular junctions. The inlet portions of 2 Jarvik 2000 pumps were positioned through their respective sewing rings at the mid-atrial level and the pulseless atrial reservoir connected end-to-end to the pulmonary artery and aorta. Pulseless systemic and pulmonary circulations were thereby achieved. Volume status was controlled, and systemic and pulmonary resistance were managed pharmacologically to keep mean arterial pressures at 100+/-10 mmHg (systemic) and 20+/-5 mmHg (pulmonary) and both left and right atrial pressures at 15+/-5 mmHg. The left pump speed was maintained at 14,000 rpm and its output autoregulated in response to variations in right pump flow, systemic and pulmonary pressures, fluid status, and activity level. Hemodynamics, end-organ function, and neurohormonal status remained normal. These results suggest the feasibility of using dual continuous-flow pumps as a TAH.

Animals↗

Mechanical bridging to improvement in severe acute "nonischemic, nonmyocarditis" heart failure.

Improved myocardial function has been observed in patients with acute myocarditis who have had short-term support with a ventricular assist system. Additionally, a limited number of patients with nonischemic cardiomyopathy have undergone successful device explantation after their myocardial function improved during ventricular assist system support. The authors present their experience with four patients who had acute, severe heart failure without coronary artery disease or biopsy-proven myocarditis. After receiving prolonged ventricular assist system support, all four patients had significantly improved left ventricular function, returning to New York Heart Association functional class I without inotropic therapy. In each case, dobutamine stress echocardiography and invasive hemodynamic tests were performed to confirm improvement of cardiac function before device explantation was undertaken. In all four cases, device explantation was followed by early successful maintenance of left ventricular function. These cases reveal a unique clinical syndrome that may be successfully treated with early institution of ventricular assist system support followed by explantation after myocardial recovery.

Acute Disease↗

Jarvik 2000 FlowMaker axial-flow left ventricular assist device support for management of refractory ventricular arrhythmias.

Chronic congestive heart failure is not uncommonly associated with ventricular arrhythmias. In a small percentage of these cases, the arrhythmias may become refractory to medical therapy and exacerbate the patient's underlying heart failure. The authors report such a case, in which ventricular failure necessitated insertion of a Jarvik 2000 FlowMaker left ventricular assist device (Jarvik Heart Inc., New York, NY). In addition to normalizing the cardiac output, this axial-flow device controlled the previously unremitting ventricular arrhythmia.

Adult↗

Long-term destination therapy with the HeartMate XVE left ventricular assist device: improved outcomes since the REMATCH study.

The Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) trial demonstrated increased 1- and 2-year survival and improved quality of life for end-stage heart failure patients implanted with the HeartMate VE Left Ventricular Assist Device (LVAD) (Thoratec Corporation, Pleasanton, CA) compared with optimal medical management. This is the first report of Destination Therapy (DT) experience since REMATCH and incorporates improvements with the HeartMate XVE LVAD and patient management. Forty-two patients with end-stage heart failure at higher volume institutions were supported with the LVAD over a duration of 26.7 patient years (mean 232 days). Compared with REMATCH, DT patients had a 40% lower rate of death (0.49 vs. 0.84 deaths per patient year). Kaplan-Meier estimates of survival in the DT and REMATCH LVAD groups at 30 days were 90% and 81%, and at 1 year were 61% and 52%. The death rate due to sepsis was 8.3 times lower in DT patients (risk ratio, 0.12; 95% confidence interval, 0.02-0.90). DT patients were 2.1 times less likely to experience an adverse event (risk ratio, 0.47; 95% confidence interval, 0.35-0.63). These results demonstrate continued improvement with outcomes in long-term DT with LVADs. Given that these DT patients were similar to those in the REMATCH trial, the improved outcomes likely reflect improvements in the HeartMate XVE LVAD and experience with patient management.

Adult↗

Myocardial perfusion as assessed by positron emission tomography during long-term mechanical circulatory support.

Although mechanical circulatory support (MCS) can improve myocardial function in patients with advanced heart failure, its effects on relative myocardial perfusion are unclear. Using positron emission tomographic imaging techniques, the authors assessed relative myocardial perfusion in patients with ischemic or idiopathic cardiomyopathy who were receiving chronic MCS with a left ventricular assist device (pulsatile HeartMate [n = 2] [Thoratec Corporation, Pleasanton, CA] or nonpulsatile Jarvik 2000 [n = 4] [Jarvik Heart, Inc., New York, NY]). Relative myocardial perfusion was compared at lower and higher levels of MCS (50 vs. 100 - 110 ejections/min for the HeartMate and 8000 vs. 12,000 rpm for the Jarvik 2000). The size and severity of perfusion defects at rest and after dipyridamole stress were measured objectively and subjectively by computer algorithms and visual inspection, respectively. Relative myocardial perfusion increased > 5% from baseline in only one of six patients when MCS was increased. No change in relative myocardial perfusion of > 5% was seen in any of the other five patients, even after subsequent dipyridamole stress positron emission tomographic imaging. These pilot study findings suggest that the decreased metabolic requirements induced by ventricular unloading correspondingly decreased blood flow requirements to physiologically inactive myocardium.

Adult↗

Partial left ventriculectomy and limited heart transplantation availability.

BACKGROUND AND AIM: Partial left ventriculectomy, a novel cardiac volume reduction operation, is applied in countries without a developed heart transplantation program. We sought to determine its impact in our population of patients. METHODS: Partial left ventriculectomy was performed in 38 patients during the last 4 years. Basic inclusion criteria were nonischemic dilated cardiomyopathy and poor response to medical therapy for heart failure. Hemodynamic evaluation was carried out before and after operation. A modified surgical technique of mitral valve repair and ventricle suturing was applied. RESULTS: Thirty-day, 6-month, and 2-year survival rates were 82% +/- 7%, 65% +/- 8%, and 61% +/- 9%, respectively. Duration of heart failure symptoms was the only predictor of survival (p = 0.042). A high proportion of noncardiac causes of death was noted. Functional capacity in surviving patients improved at every successive measurement up to 1 year postoperatively. CONCLUSIONS: The introduction of partial left ventriculectomy in a country with limited heart transplantation availability had a great impact on the management of end-stage heart failure and may represent the only surgical option for some patients. The average cost per patient was substantially lower when compared to heart transplantation.

Adult↗

Guillain-Barré syndrome after heart transplantation.

We present two cases of Guillain-Barré syndrome (acute idiopathic neuritis) that developed after heart transplantation involving immunosuppression with cyclosporine, azathioprine, and steroids. The literature contains only two previous reports of posttransplant Guillain-Barré syndrome, both involving patients maintained with azathioprine and steroid immunosuppression after kidney transplantation. In our two cases (and in one of the previous cases), the syndrome was preceded by a sudden increase in the amount of serum immunoglobulin M antibody to cytomegalovirus. One of our patients improved neurologically after plasmapheresis, but neither patient appeared to benefit from the administration of gamma globulin. Because further immunosuppression would predispose the transplant patient to other opportunistic infections, we advocate a trial of plasmapheresis in the treatment of Guillain-Barré syndrome in this population.

Cytomegalovirus Infections↗

Leishmaniasis in a heart transplant patient.

Infection is a well-recognized complication of immunosuppressive therapy. We describe a case of leishmaniasis in a 62-year-old man who was undergoing immunosuppressive therapy because of heart transplantation. A geologist and native Texan, the patient had traveled extensively in south-central Texas, but not outside of the continental United States. Cutaneous lesions of the extremities developed, which were diagnosed histologically as leishmaniasis and confirmed by means of transmission electron microscopy. Cultures grew Leishmania mexicana. Treatment with sodium antimony gluconate was successful in healing the infective lesions.

Animals↗

Reevaluation of steroid tapering after steroid pulse therapy for heart rejection.

A retrospective analysis was conducted to determine the efficacy and complications resulting from steroid pulse therapy, with or without a steroid taper, in 93 episodes of heart transplant rejection that occurred in 72 patients (58 men, 14 women; mean age, 47.6 years). Each rejection episode was classified according to severity (Texas Heart Institute endomyocardial biopsy scale) and the treatment. Group 1 included 25 episodes of grade 7, 8, 9, or 10 rejection (International Society for Heart Transplantation [ISHT] grade IIIB or IV) that were treated with high-dose methylprednisolone (2.5 to 3.0 gm) and a steroid taper of 1.75 gm over 30 days. Group 2 included 16 episodes of rejection, with the severity of rejection and methylprednisolone pulse therapy being similar to that in group 1, but without a steroid taper. The results of treatment in group 1 were compared with those in group 2. Group 3 included 12 episodes of grade 5, 6, or 7 rejection (ISHT grade IIIA or IIIB) that were treated with moderate-dose methylprednisolone (1.0 to 2.0 gm) and a steroid taper, as described. Group 4 included 40 episodes of rejection, with the severity of rejection and methylprednisolone therapy being similar to that of group 3, but without a steroid taper. The results of treatment in group 3 were compared with those in group 4. No statistically significant differences were found among the groups regarding subsequent episodes of rejection or infection within 3 months of treatment. No statistically significant difference was noted among the groups in the number of rejection episodes requiring additional therapy to control the rejection.(ABSTRACT TRUNCATED AT 250 WORDS)

Female↗

Neurologic complications of heart transplantation in children.

Neurologic complications can add significant morbidity to otherwise successful orthotopic heart transplantations in children. Complications have been reported to occur in up to 50% of children undergoing heart transplantation. The purpose of this study was to identify the prevalence and outcome of neurologic complications of heart transplantation in children. We reviewed all children who received orthotopic heart transplantation at Texas Children's Hospital from November 1984 to November 1990. Twenty-two patients (ages, 3 weeks to 17 years; mean, 8.5 years) underwent heart transplantation using cardiopulmonary bypass with moderate hypothermia. For analysis, we compared results during the first 3 years of our experience, 1984 through 1987 (group 1), to 1987 through 1990 (group 2). Survival was 45% (5 of 11 patients) for group 1 and 73% (8 of 11 patients) for group 2. A neurologic complication was defined as a change in the neurologic examination and/or status. Neurologic complications included seizures (6 of 22 patients), strokes (3 of 22 patients), unresponsiveness (3 of 22 patients), and change in mental status (2 of 22 patients). Early (within 2 weeks after operation) neurologic complications occurred in 45% (10 of 22 patients), were persistent (sequelae lasting more than 4 months) in 27% (6 of 22 patients), and resulted in death in 9% (2 of 22 patients). Late (after 2 weeks after operation) neurologic complications occurred in 23% (5 of 22 patients), were persistent in 9% (2 of 22 patients), and have occurred in only two survivors. Neurologic factors were not responsible for the cause of death in group 2. No neurologic complications (early or late) were seen in 1 of 11 patients in group 1 as compared with 7 of 11 patients in group 2 (p < 0.015). Serious neurologic morbidity decreased between the two groups after preoperative cyclosporine was avoided and postoperative hypertension was controlled. All survivors are functioning at age-appropriate levels. Although neurologic complications may be frequent, long-term neurologic disability in survivors is rare.

Adolescent↗