PubMed Health⌕ Search

Biomedical subjects

O H Frazier

Publications and source records attributed to O H Frazier.

At least 55 records · Page 3Linked to original sources

Total circulatory support with an LVAD in an adolescent with a previous Fontan procedure.

We report the case of a 14-year-old boy who developed ischemic contracture of the heart after open heart surgery to correct complex congenital heart disease. Because he had no cardiac function, an extracorporeal, continuous-flow device was used to support him until he was transferred to our institution. Shortly after his arrival, an implantable, long-term left ventricular assist device was implanted. The univentricular pump provided total cardiac support for this critically ill patient. After normalization of end-organ function, the patient underwent successful orthotopic cardiac transplantation.

Adolescent↗

Posttransplant off-pump coronary bypass and laser revascularization in a Jehovah's Witness.

A 57-year-old man, who had received a heart transplant 14 years earlier, underwent coronary artery bypass grafting and transmyocardial laser revascularization for left main, left anterior descending, and circumflex coronary artery disease. The procedures were performed through a left thoracotomy incision without cardiopulmonary bypass. Because the patient was of the Jehovah's Witness faith, no blood or blood products were transfused.

Adult↗

Orthotopic heart transplantation in a patient with D-transposition of the great arteries: after a Mustard procedure.

During heart transplantation, the atrial septum is most often used to reconstruct the right atrial reservoir. We report the case of a patient with corrected D-transposition of the great arteries who underwent successful cardiac transplantation despite the lack of an atrial septum. We then used the donor heart's atrial septum for the roof of the left atrium and used the recipient's left atrium for the back wall of the left atrium. The outcome was a more anatomically positioned transplanted heart, which avoided the duplication of the right and left atria that occurs in conventional orthotopic transplantation and that often leads to left-lower-lobe atelectasis and tricuspid regurgitation. This method of orthotopic transplantation should be considered for, but not limited to, the growing number of adults with congenital heart disease who require heart transplantation.

Adult↗

Left ventricular assist device implantation in a patient with congenitally corrected transposition of the great arteries.

Congenitally corrected transposition of the great arteries (ccTGA) is a rare anomaly characterized by atrioventricular and ventriculo-arterial discordance and several other malformations that eventually lead to heart failure. We describe the case of a 53-year-old woman with ccTGA and aortic insufficiency who was a candidate for heart transplantation due to end-stage congestive heart failure. Her condition deteriorated before a suitable donor heart could be found; therefore, we placed a left ventricular assist device in the right (systemic) ventricle. Concomitantly, we removed the aortic (systemic) valve, closed the aortic annulus with a bovine pericardial patch, and repaired the mitral valve. The patient recovered uneventfully and was discharged from the hospital 2 months postoperatively. She underwent cardiac transplantation approximately 6 months later and continued to do well after 18 months.

Female↗

HeartMate VE LVAS design enhancements and its impact on device reliability.

OBJECTIVE: The HeartMate VE left ventricular assist system (LVAS) has supported more than 2300 patients and has been shown to be effective for bridge to cardiac transplantation and has demonstrated improved outcomes in survival as a destination therapy. Improvements in device durability are needed as bridge to transplant times increase and as we move into the era of LVAD as destination therapy. The purpose of this study is to determine if design enhancements to the HeartMate LVAS have improved device reliability and durability. METHODS: A retrospective analysis of serious mechanical failures was performed in 1865 devices (1458 VE, 407 XVE). The analysis of data included devices used to support patients from September 1998 for bridge to transplantation and destination therapy. Serious mechanical failures were defined as inflow valve dysfunction, percutaneous lead breaks, diaphragm fractures or punctures, bearing failures, outflow graft erosion and pump disconnects. RESULTS: Median device duration for the VE was 97 days (max 1206 days), and 85 days (max 517 days) for the XVE. A total of 134 serious mechanical failures occurred and included inflow valve dysfunction (5.3% VE, 2.4% XVE) (P = 0.853) percutaneous lead breaks (1.9% VE, 0% XVE) (P < 0.001) diaphragm fractures (0.1% VE, 0% XVE) (P = 0.134) outflow graft erosion (0.2% VE, 0% XVE) (P = 0.1096), pump disconnects (0.1% VE, 0% XVE) (P = 0.1336) and bearing failures (0.6% VE, 0.2% XVE) (P = 0.5538). Of the XVEs 97% were free of serious mechanical failures at 6 months and 82% at 1 year compared to 92 and 73% for the VE, respectively. The 6-month difference between the devices was statistically significant (P = 0.0063) and there was no statistically significant difference at 1 year (P = 0.1492). CONCLUSIONS: Preliminary experience with the HeartMate XVE LVAS demonstrated a significant reduction in percutaneous lead breaks. Early trends indicate positive impact of recent design modifications on XVE performance. These design modifications may improve device durability and reliability, which is crucial as we enter the era of LVADs as an alternative to medical therapy.

Follow-Up Studies↗

HeartMate vented-electric left ventricular assist system: technique for intrathoracic or intraperitoneal implantation via a left thoracotomy.

The HeartMate vented-electric left ventricular assist system (Thoratec Corp., Woburn, MA) has become widely accepted as a temporary bridge to transplantation. We describe a left thoracotomy technique in 3 patients for implanting this pump intrathoracically or intraperitoneally. In all 3 cases, long-term pump function was satisfactory. For HeartMate implantation, the left thoracotomy approach may be particularly useful when previous median sternotomies, coupled with the severe debilitation posed by chronic heart failure and hepatic dysfunction with resultant coagulopathy, would greatly increase the mortality and morbidity of a redo median sternotomy.

Cardiopulmonary Bypass↗

Fatal disseminated adenoviral infection in an adult heart transplant patient.

In heart transplant recipients, infection is one of the leading causes of morbidity and mortality. In adult heart transplant patients, cytomegalovirus is the most frequently encountered viral pathogen. Conversely, disseminated adenoviral infection is observed mainly in children, where it is predictive of allograft rejection and coronary vasculopathy. The literature contains only a few reports of adenoviral infections in adult heart transplant recipients. Limited information is available concerning the diagnosis and epidemiology of such infections and their relationship to organ rejection, heart failure and overall outcomes in these patients. To promote an awareness of this potentially lethal complication, we present a case of fatal disseminated adenoviral infection in an adult heart transplant recipient.

Adenoviridae Infections↗

Initial experience with the AbioCor implantable replacement heart system.

OBJECTIVE: We sought to evaluate the safety and efficacy of the first available totally implantable replacement heart (AbioCor Implantable Replacement Heart System) in the treatment of severe, irreversible biventricular heart failure in human patients. METHODS: Seven male adult patients with severe, irreversible biventricular failure (>70% thirty-day predicted mortality) who were not candidates for transplantation met all institutional review board study criteria and had placement of the AbioCor Implantable Replacement Heart. All were in cardiogenic shock despite maximal medical therapy, including inotropes and intra-aortic balloon pumps. Mean age was 66.7 +/- 10.4 years (range, 51-79 years). Four of 7 patients had prior operations. Six had ischemic and one had idiopathic cardiomyopathy. All had 3-dimensional computer-simulated implantation of the thoracic unit that predicted adequate fit. At the time of the operation, the internal transcutaneous energy transfer coil, battery, and controller were placed. Biventriculectomy was then performed, and the thoracic unit was placed in an orthotopic position and attached to the atrial cuffs and outflow conduits with quick-connects. The flow was adjusted to 4 to 8 L/min. Central venous and left atrial pressures were maintained at 5 to 15 mm Hg. The device is powered through transcutaneous energy transfer. An atrial flow-balancing chamber is used to adjust left/right balance. The balance chamber and transcutaneous energy transfer eliminate the need for percutaneous lines. RESULTS: There was one intraoperative death caused by coagulopathic bleeding and one early death caused by an aprotinin reaction. There have been multiple morbidities primarily related to preexisting illness severity: 5 patients had prolonged intubation, 2 had hepatic failure (resolved in 1), 4 had renal failure (resolved in 3), and 1 each had recurrent gastrointestinal bleeding, acute cholecystitis requiring laparotomy, respiratory failure that resolved after 3 days of extracorporeal membrane oxygenation, and malignant hyperthermia (resolved). There were 3 late deaths: one caused by multiple systems organ failure (postoperative day 56), one caused by a cerebrovascular accident (postoperative day 142), and one caused by retroperitoneal bleeding and resultant multiple systems organ failure (postoperative day 151). This latter patient was not able to tolerate anticoagulation (no anticoagulation or antiplatelet therapy alone for 80% of the first 60 days) and had a transient ischemic attack on postoperative day 61 and a cerebrovascular accident on postoperative day 130. At autopsy, blood pumps were clean. The 2 patients who had large cerebrovascular accidents had thrombus on the atrial cage struts. These struts have been removed for future implants. There has been no significant hemolysis or device-related infections. The balance chamber has allowed for left/right balance in all patients (left atrial pressure within 5 mm Hg of right atrial pressure). Three patients have taken multiple (>50) trips out of the hospital, and 2 have been discharged from the hospital. Total days on support with the AbioCor are 759. CONCLUSION: The initial clinical experience suggests that the AbioCor might be effective therapy in patients with advanced biventricular failure. There have been no significant device malfunctions. Two of these patients have been discharged from the hospital.

Aged↗

Preclinical assessment of a trileaflet mechanical valve in the mitral position in a calf model.

BACKGROUND: The bileaflet valve is currently the mechanical replacement valve of choice. Though durable, it does not closely mimic native valve hemodynamics and remains potentially thrombogenic. METHODS: Prototype trileaflet valves (T1 and T2) were implanted in the mitral position in calves. Group I calves received either a T1 valve (n = 12) or a control bileaflet valve (n = 5); Group II, either a T2 valve (n = 7) or a control bileaflet valve (n = 5). Valve function, perivalvular leakage, and transvalvular pressure gradients were evaluated. Also, long-term prototype leaflet wear was evaluated in vivo in one Group I calf (502 days) and two Group II calves (385 and 366 days). Calves were euthanized and necropsied at study termination, and major organs weighed and examined. RESULTS: Valve function was excellent and hematologic parameters remained normal in all calves that survived to study termination. Mean peak transvalvular pressure gradients were 10 +/- 7 mm Hg for T1 valves, 6 +/- 3 mm Hg for T2 valves, and 12 +/- 4 mm Hg for bileaflet control valves. Clinically insignificant valvular regurgitation was observed in both prototypes. Explanted valves showed no thrombus-impaired leaflet motion, except in two T1-fitted calves and one T2-fitted calf. Major organs showed no evidence of clinically significant thromboembolic events. There were no other significant differences between the results of experimental and control groups. CONCLUSIONS: Prototype trileaflet valves performed safely and effectively in the mitral position in calves, even without long-term anticoagulation. This warrants their evaluation as an equivalent alternative to bileaflet valves.

Animals↗

Clinical experience with an implantable, intracardiac, continuous flow circulatory support device: physiologic implications and their relationship to patient selection.

BACKGROUND: We have been investigating continuous-flow circulatory support devices for 20 years. Unlike pulsatile assist devices, continuous-flow pumps have a simplified pumping mechanism and they do not require compliance chambers or valves. In the 1980s, clinical experience with the Hemopump proved a high-speed, intravascular, continuous-flow pump could safely augment the circulation. Subsequently, a decade of animal experiments with a larger, longer-term continuous-flow pump (the Jarvik 2000) confirmed the safety and efficacy of intraventricular placement, leading to its clinical application. METHODS: We analyzed the physiologic and anatomic effect of using the Jarvik 2000 pump for cardiac support in 23 patients in whom the device was applied as a bridge to transplant under the protocol approved by the Food and Drug Administration Investigational Device Exemption. The device was used as a bridge to transplantation in 20 patients and as destination therapy in 3 patients. RESULTS: In the bridge-to-transplant group, 14 patients underwent transplantation, 5 died during the circulatory support period and 1 is in an ongoing study. The support period lasted an average of 90 days. For the survivors, the follow-up period has averaged 16 months. Within the first 48 postoperative hours, the average cardiac index increased by 65% (from 1.77 +/- 0.24 to 2.92 +/- 0.60 L. min(-1). m(-2), p = 0.00000002), the systemic vascular resistance decreased by 42% (from 1604 +/- 427 to 930 +/- 330 dynes/sec per cm(2), p = 0.00001), and the pulmonary capillary wedge pressure (PCWP) decreased by 41.8% (from 23 +/- 5.1 to 13.4 +/- 6.6 mm Hg, p = 0.00009). Similar results were seen for the patients undergoing destination therapy. Cardiac index increased 89.5% (from 1.9 +/- 0.1 to 3.6 +/- 0.6, p = 0.046) and PCWP decreased by 52.2% (from 23 +/- 10 to 11 +/- 2, p = 0.22). In that group, 1 patient died unexpectedly from an accident 382 days after device implantation. The 2 survivors remain in New York Heart Association (NYHA) functional class I at 700 to 952 days after implantation. CONCLUSIONS: The Jarvik 2000 can offer effective long-term support for patients with chronic heart failure and NYHA class IV status. However, the new physiology produced by continuous offloading of the heart throughout the cardiac cycle has introduced unique clinical problems. The understanding of the problems generated by this biotechnological interface is essential for obtaining optimal clinical outcomes.

Adult↗

Degree of cardiac fibrosis and hypertrophy at time of implantation predicts myocardial improvement during left ventricular assist device support.

BACKGROUND: There have been increasing reports of cardiac improvement in heart failure patients supported by left ventricular assist devices (LVADs i.e.), including a number of patients who have tolerated removal of the device without the benefit of cardiac transplant. In the current study, we retrospectively investigated echocardiographic and histologic changes in patients supported by LVADs (n = 18). The goal of our study was to determine if the degree of cardiac fibrosis and myocyte size in pre-implant biopsies could predict myocardial improvement as assessed by improvements in ejection fraction (EF) during LVAD support. METHODS: We determined total collagen content in myocardial biopsy specimens by a semi-quantitative analysis of positive Picro-Sirius Red-stained areas and myocyte size measurements by computerized edge detection software. RESULTS: During LVAD support, 9 of the 18 patients (Group A) were distinguished by significant improvement in ejection fraction (pre <20% vs unloaded 34 +/- 5%). In addition, Group A patients had significantly less fibrosis and smaller myocytes than their Group B counterparts, whose EF did not improve. There was an inverse correlation between pre-implant biopsy collagen levels and myocyte size with increases in EF during LVAD unloading. CONCLUSIONS: We found that the patients who demonstrated the greatest improvements in EF during support had less fibrosis and smaller myocytes at the time of device implantation. We propose that tissue profiling a patient's pre-implant biopsy for fibrosis and myocyte size may allow stratification in Stage IV heart failure and may predict myocardial improvement during LVAD support.

Adolescent↗

Comparison of intravenous ganciclovir and cytomegalovirus hyperimmune globulin pre-emptive treatment in cytomegalovirus-positive heart transplant recipients.

BACKGROUND: We compared the use of intravenous ganciclovir and cytomegalovirus hyperimmune globulin (CMVIG) as a pre-emptive treatment for cytomegalovirus (CMV)-positive heart transplant recipients. METHODS: Of 59 CMV-seropositive adult heart transplant recipients enrolled in Group 1, 37 tested positive for pp65 antigen within 12 weeks post-transplantation. These patients were randomized to receive either intravenous ganciclovir (n = 23) or CMVIG (n = 14). Group 2 included 133 CMV-seropositive heart transplant recipients who were not tested for CMV antigenemia and who received no anti-CMV therapy. RESULTS: CMV disease developed in 0 of 59 patients from Group 1, and in 27 of 133 patients (20%) in Group 2 (p = 0.0001). The incidence of superinfections was lower in Group 1 (0.28 +/- 0.46) than in Group 2 (1.10 +/- 1.33) (p = 0.01). The 2 groups did not differ with regard to incidence of rejection (0.7 +/- 0.9 in Group 1 vs 1.0 +/- 1.2 in Group 2; p = NS), transplant coronary artery disease at 1 year (14% in Group 1 vs 16% in Group 2; p = NS) or post-transplant lymphoproliferative disease (0% in Group 1 vs 2% in Group 2; p = NS). Ganciclovir and CMVIG therapies were associated with similar rates of rejection (0.52 +/- 0.6 with ganciclovir vs 0.50 +/- 0.60 with CMVIG; p = NS), superinfection (0.30 +/- 0.48 with ganciclovir vs 0.25 +/- 0.46 with CMVIG; p = NS), and transplant coronary artery disease at 1 year (13% with ganciclovir vs 14% with CMVIG, p = NS). CONCLUSIONS: The pre-emptive anti-CMV approach is superior to prophylaxis in CMV-seropositive heart transplant recipients. Both ganciclovir and CMVIG are equally effective.

Adult↗

Intramyocardial lipid accumulation in the failing human heart resembles the lipotoxic rat heart.

In animal models of lipotoxicity, accumulation of triglycerides within cardiomyocytes is associated with contractile dysfunction. However, whether intramyocardial lipid deposition is a feature of human heart failure remains to be established. We hypothesized that intramyocardial lipid accumulation is a common feature of non-ischemic heart failure and is associated with changes in gene expression similar to those found in an animal model of lipotoxicity. Intramyocardial lipid staining with oil red O and gene expression analysis was performed on heart tissue from 27 patients (9 female) with non-ischemic heart failure. We determined intramyocardial lipid, gene expression, and contractile function in hearts from 6 Zucker diabetic fatty (ZDF) and 6 Zucker lean (ZL) rats. Intramyocardial lipid overload was present in 30% of non-ischemic failing hearts. The highest levels of lipid staining were observed in patients with diabetes and obesity (BMI>30). Intramyocardial lipid deposition was associated with an up-regulation of peroxisome proliferator-activated receptor alpha (PPARalpha) -regulated genes, myosin heavy chain beta (MHC-beta), and tumor necrosis factor alpha (TNF-alpha). Intramyocardial lipid overload in the hearts of ZDF rats was associated with contractile dysfunction and changes in gene expression similar to changes found in failing human hearts with lipid overload. Our findings identify a subgroup of patients with heart failure and severe metabolic dysregulation characterized by intramyocardial triglyceride overload and changes in gene expression that are associated with contractile dysfunction.

Adult↗

Use of the Flowmaker (Jarvik 2000) left ventricular assist device for destination therapy and bridging to transplantation.

The Flowmaker left ventricular assist device (formerly known as the Jarvik 2000) is an axial-flow pump that provides continuous flow from the left ventricle to the aorta. Designed for either temporary or permanent use, the Flowmaker is undergoing clinical trials in the United States and Europe. The goal of this therapy is to provide adequate circulatory flow while partially reducing the left ventricular size and end-diastolic pressure. This gives the native ventricle an opportunity to remodel itself. Those who benefit the most from this technology are patients who require only true left ventricular assistance rather than total capture of the left ventricular output. Because of the Flowmaker's simplicity and safety of implantation, as well as the absence of late pump failure, its use may be justified in severely impaired class III and IV (but not preterminal) heart failure patients.

Clinical Trials as Topic↗

The total artificial heart: where we stand.

The AbioCor total artificial heart (TAH) is undergoing clinical feasibility testing as destination therapy in patients with end-stage congestive heart failure. So far, the device has been implanted in 11 of a projected 15 patients. The TAH has performed reliably, providing adequate circulatory support while extending survival and improving quality of life in most recipients. Thromboembolism remains a problem but is being addressed by optimizing device and patient management and refining the anticoagulation protocol. Because the device is totally implantable and requires no penetration of the skin, infection has been minimized. All recipients so far have been men. The device is large and this limits its use in smaller patients (i.e. women, small men and children). A smaller version is being developed. Although it has yet to receive Food and Drug Administration approval, the early clinical results suggest that the AbioCor TAH may become an accepted alternative to heart transplantation for selected patients with end-stage congestive heart failure. Further investigation with regard to its primary clinical applicability, i.e. as a rescue device for sudden catastrophic heart failure, is warranted.

Aged↗