PubMed Health⌕ Search

Biomedical subjects

O Heber

Publications and source records attributed to O Heber.

At least 19 recordsLinked to original sources

Size-dependent electron-impact detachment of internally cold Cn- and Aln- clusters.

The cross sections for electron detachment of internally cold Cn- and Aln- clusters were measured using an electrostatic ion beam trap fitted with an internal electron target. The measured electron-impact detachment cross sections for the Cn- (n = 1-9) clusters exhibit even-odd oscillations reflecting the binding energy trend, namely, higher cross sections for weaker binding. Surprisingly, however, these cross sections increase on the average with cluster size, n, in spite of the increase in electron binding. In contrast, the Aln- (n = 2-5) clusters follow the known scaling laws for electron detachment. We suggest that the size-dependent polarizability of these clusters is responsible for the observed behavior.

Journal Article↗

Evidence for subthermal rotational populations in stored molecular ions through state-dependent dissociative recombination.

We demonstrate that the dissociative recombination of D2H+ with low-energy electrons depends on the rotational energy of the molecular ion such that highly excited ions have a larger rate coefficient than colder ones. Observations on an ion beam continuously interacting with electrons at low relative velocity indicate that excited rotational levels are preferentially depleted which, in competition with radiative heating due to blackbody radiation, provides an opportunity for controlling the rotational temperature of stored molecules.

Journal Article↗

Negative mass instability for interacting particles in a 1D box: theory and application.

We demonstrate that the synchronization effect observed [Pedersen et al., Phys. Rev. Lett. 87, 055001 (2001)]], when a bunch of ions oscillates between two mirrors in an electrostatic ion beam trap, can be explained as a negative mass instability. We derive simple necessary conditions for the existence of a regime in which this dispersionless behavior occurs and demonstrate that in this regime, the ion trap can be used as a high resolution mass spectrometer.

Journal Article↗

Ion motion synchronization in an ion-trap resonator.

Using a new type of ion trap, we demonstrate that the length of a packet of charged particles oscillating between two electrostatic mirrors will remain constant under special conditions. The effect can be understood in terms of phase synchronization, where, in a rather counterintuitive way, the repulsive Coulomb interaction between the ions actually holds the packet together. Application of this effect for mass spectrometry is discussed.

Journal Article↗

Fourier transform time-of-flight mass spectrometry in an electrostatic ion beam trap

We report on the application of an electrostatic ion beam trap as a mass spectrometer. The instrument is analogous to an optical resonator; ions are trapped between focusing mirrors. The storage time is limited by the residual gas pressure and reaches up to several seconds, resulting in long ion flight paths. The oscillation of ion bunches between the mirrors is monitored by nondestructive image charge detection in a field-free region and mass spectra are obtained via Fourier transform. The principle of operation is demonstrated by measuring the mass spectrum of trapped Ar+ and Xe+ particles, produced by a standard electron impact ion source. Also, mass spectra of heavier PEGnNa+ and bradykinin ions from a pulsed MALDI ion source were obtained. The long ion flight path, combined with mass-independent charge detection, makes this system particularly interesting for the investigation of large molecules.

Journal Article↗