Evaluation of the buccal component of systemic absorption with inhaled fluticasone propionate.

BACKGROUND: Inhaled corticosteroids have dose related systemic effects determined by oral (swallowed or oropharyngeal absorption) and lung bioavailability. A study was undertaken to evaluate the significance of oropharyngeal absorption for fluticasone propionate. METHODS: Sixteen healthy volunteers of mean age 29.3 years were studied using an open randomised, placebo controlled, four way crossover design. Treatments were: (a) fluticasone metered dose inhaler (pMDI) 250 microg, 8 puffs; (b) fluticasone pMDI 250 microg, 8 puffs + mouth rinsing/gargling (water); (c) fluticasone pMDI 250 microg, 8 puffs + mouth rinsing/gargling (charcoal); and (d) placebo pMDI, 8 puffs + mouth rinsing/gargling (water). Overnight (ONUC) and early morning (EMUC) urinary cortisol/creatinine ratios and 8 am serum cortisol (SC) levels were measured. RESULTS: Significant (p<0. 05) suppression of ONUC, EMUC, and SC occurred with each active treatment compared with placebo. The mean values (95% CI for difference from placebo) were: (a) ONUC (nmol/mmol): fluticasone (2. 8, 95% CI 3.6 to 7.9), fluticasone + water (3.1, 95% CI 3.3 to 7.7), fluticasone + charcoal (2.3, 95% CI 4.1 to 8.5); placebo (8.6); (b) EMUC (nmol/mmol): fluticasone (5.6, 95% CI 8.4 to 24.5), fluticasone + water (7.6, 95% CI 6.6 to 22.4); fluticasone + charcoal (5.6, 95% CI 8.7 to 24.5); placebo (22.1). There were no significant differences between active treatments. The numbers of subjects with an overnight urinary cortisol of <20 nmol/10 hours were 0 (placebo), 11 (fluticasone), 12 (fluticasone + water), and 13 (fluticasone + charcoal). CONCLUSIONS: Oropharyngeal absorption of fluticasone does not significantly contribute to its overall systemic bioactivity as assessed by sensitive measures of adrenal suppression. In view of almost complete hepatic first pass inactivation with fluticasone, there is no rationale to employ mouth rinsing to reduce its systemic effects although it may be of value for reducing oral candidiasis.

Absorption↗

Evaluation of the effect of a large volume spacer on the systemic bioactivity of fluticasone propionate metered-dose inhaler.

BACKGROUND: Inhaled corticosteroids such as fluticasone propionate (FP) have dose-related systemic effects, including adrenal suppression. We have therefore investigated the effect of adding a large volume spacer on the systemic bioactivity of FP given via a pressurized metered-dose inhaler (pMDI). METHODS: Fourteen healthy volunteers (mean age, 29.9 years old) were studied using an open, randomized, placebo-controlled, three-way crossover design. Single doses of the following were given at 5:00 PM in a randomized sequence: (1) eight puffs of FP by pMDI, 1.76 mg (250 microg ex-valve, 220 microg ex-actuator); (2) eight puffs of FP by pMDI, 250 microg, with 750-mL spacer (Volumatic; Allen & Hanburys; Uxbridge, UK); and (3) eight puffs of placebo by pMDI. Measurements were made after each dose, including overnight and early morning urinary cortisol/creatinine ratios and 8:00 AM serum cortisol. RESULTS: Significant (p < 0.05) suppression of all three end points occurred with each active treatment compared to treatment with placebo. Furthermore, significant (p < 0.05) additional suppression occurred when comparing FP by pMDI alone to FP by pMDI with spacer. Geometric mean fold differences (95% confidence interval for fold difference) between FP by pMDI alone and FP by pMDI with spacer were 1.94-fold (1.00-3.78) for overnight urinary cortisol/creatinine ratio and 1.98-fold (1.26-3.10) for 8:00 AM serum cortisol. This was mirrored by a twofold rise in the number of values for uncorrected overnight urinary cortisol < 10 nmol/10 h: placebo treatment (none of 14 subjects); FP by pMDI (6 of 14 subjects; 43%); and FP by pMDI with spacer (12 of 14 subjects; 86%). CONCLUSIONS: The use of a large volume spacer with FP by pMDI results in a twofold increase in the systemic bioavailability as assessed by sensitive measures of adrenal suppression. This, in turn, reflects a twofold improvement in respirable dose delivery with the spacer device.

Administration, Inhalation↗