Temperature limit values for touching cold surfaces with the fingertip.

OBJECTIVES: At the request of the European Commission and in the framework of the European Machinery Directive, research was performed in five different laboratories to develop specifications for surface temperature limit values for the short-term accidental touching of the fingertip with cold surfaces. METHODS: Data were collected in four laboratories with a total of 20 males and 20 females performing a grand total of 1655 exposures. Each touched polished blocks of aluminium, stainless steel, nylon-6 and wood using the distal phalanx of the index finger with a contact force of 1.0, 2.9 and 9.8 N, at surface temperatures from +2 to -40 degrees C for a maximum duration of 120 s. Conditions were selected in order to elicit varying rates of skin cooling upon contact. Contact temperature (TC) of the fingertip was measured over time using a T-type thermocouple. RESULTS: A database obtained from the experiments was collated and analysed to characterize fingertip contact cooling across a range of materials and surface temperatures. The database was subsequently used to develop a predictive model to describe the contact duration required for skin contact temperature to reach the physiological criteria of onset of pain (15 degrees C), onset of numbness (7 degrees C) and onset of frostbite risk (0 degrees C). CONCLUSIONS: The data reflect the strong link between the risk of skin damage and the thermal properties of the material touched. For aluminium and steel, skin temperatures of 0 degrees C occurs within 2-6 s at surface temperatures of -15 degrees C. For non-metallic surfaces, onset of numbness occurs within 15-65 s of contact at -35 degrees C and onset of cold pain occurs within 5 s of contact at -20 degrees C. The predictive model subsequently developed was a non-linear exponential expression also reflecting the effects of material thermal properties and initial temperature. This model provides information for the protection of workers against the risk of cold injury by establishing the temperature limits of cold touchable surfaces for a broad range of materials, and it is now proposed as guidance values in a new international standard.

Adolescent↗

Finger skin cooling on contact with cold materials: an investigation of male and female responses during short-term exposures with a view on hand and finger size.

This study investigated the independent effects of hand anthropometry and gender upon contact cooling responses. Subjects were selected for matching hand/finger size between genders, with equal variation between individuals of each group. Fourteen volunteers (7 male, 7 female) participated, touching blocks of aluminium and stainless steel using the first phalanx of the index finger with a contact force of 1.0 N and 9.8 N, at surface temperatures of -2 degrees C and -10 degrees C. Conditions were selected in order to elicit varying rates of skin cooling upon contact. Contact temperature ( T(C)) of the finger-pad was measured over time using a T-type thermocouple. Overall, no significant difference was found between the cooling responses of males and females. In order to investigate whether differences in hand anthropometry correlated with contact cooling response, a multiple regression approach was used. Analyses of the residual variance in contact cooling data, after the effects of material type, surface temperature and finger contact force had been accounted for, showed that, under slow cooling conditions (>45 s to reach T(C)=1 degrees C), hand size correlated significantly with contact cooling response only when represented by index finger volume ( P<0.05), but gender did not. Whilst under fast cooling conditions (<25 s to reach T(C)=1 degrees C), hand size did not correlate significantly with contact cooling response at all, but gender had a significant effect ( P<0.001). Under slow cooling conditions, a larger finger (and in most cases hands) provides a higher heat content, thus giving a slower skin cooling speed. Under fast cooling conditions, the significantly longer time required for males to reach a T(C) of 1 degrees C, despite matching hand and finger size, is attributed to higher epidermal insulation provided by the thicker stratum corneum, combined with the higher starting skin temperature observed in the "slightly cool" environment.

Adaptation, Physiological↗