Velocity encoding versus acceleration encoding for pressure gradient estimation in MR haemodynamic studies.

Many methods have been proposed to extract pressure gradient maps from magnetic resonance (MR) images. They were based on the resolution of the haemodynamic model of Navier-Stokes and needed the flow acceleration to be known. Most used velocity data acquisition and computed acceleration from temporal and spatial derivatives of the velocity field. However, MR sequences have been developed in order to acquire the acceleration field directly. Here we compared direct MR measurements of acceleration field components with those calculated from MR velocity acquisitions. Two experimental phantoms were used to separately evaluate the inertial and convective components of the acceleration. Mathematical simulation of the convective phantom further explained the origin of the noise generated by the spatial and temporal derivatives of the velocity data, and the misregistration artefacts due to MR sequences. We found that direct measurement of the acceleration field generates less noise and fewer artefacts than calculation from velocity derivatives.

Acceleration↗

Local reconstruction of stenosed sections of artery using multiple MRA acquisitions.

A method for reconstructing magnetic resonance angiography (MRA) volumes from successive acquisitions is described. The method is based on double oblique acquisitions of highly anisotropic MRA volumes, each of which corresponds to reduced k-space filling. These partial k-spaces are then combined to obtain a 3D k-space adapted to the frequency spread of the angiographic image of the stenosis. The SNR-resolution compromise of MRA is thus improved by focusing the acquisition on the most relevant k-space regions. The reconstruction is performed directly in k-space by averaging the partial k-spaces. The feasibility of the method was demonstrated in studies on a Lucite stenosis phantom, on MRAs of carotid arteries using three bolus injections, and on MRAs of renal arteries using a single contrast injection.

Carotid Arteries↗

Anatomy and physiology of subcutaneous adipose tissue by in vivo magnetic resonance imaging and spectroscopy: relationships with sex and presence of cellulite.

BACKGROUND: Little is still known concerning subcutaneous adipose tissue and cellulite, and controversial questions are still under discussion. AIMS: Magnetic resonance imaging and spectroscopy were used to address two unresolved questions relating to the anatomy and physiology of subcutaneous adipose tissue. METHODS: Using high spatial resolution magnetic resonance imaging we characterized the topography of the dermo- hypodermal junction, and the three-dimensional architecture of the subcutaneous fibrous septae. Using proton spectroscopy, we measured water and lipid fractions within a fat lobule, and T1 and T2 values of the detected compounds. All these data were analysed according to sex and presence of cellulite. RESULTS: MR imaging quantified deeper indentations of adipose tissue into the dermis, and evidenced for the first time a great increase in the thickness of the inner fat layer in women with cellulite. Moreover, 3D reconstruction of the fibrous septae network showed a higher percentage of septae in a direction perpendicular to the skin surface in women with cellulite; but our study also depicted the tortuous aspect of this network. MR proton spectroscopy could not show any differences related to sex or presence of cellulite concerning T1 and T2 relaxation times of the detected compounds within a fat lobule, neither the unsaturated lipid fraction, the saturated lipid fraction, nor the water fraction. CONCLUSIONS: Magnetic resonance imaging showed that the 3D architecture of fibrous septae couldn't be modelled simply as perpendicular planes for women and tilted planes at 45 degrees for men. MR spectroscopy did not confirm the hypothesis of increased water content in the adipose tissue of women with cellulite as suggested by others, except if such water would be located in the connective septae.

Adipose Tissue↗

Precision of magnetic resonance velocity and acceleration measurements: theoretical issues and phantom experiments.

Magnetic resonance (MR) sequences have been developed for acquiring multiple components of velocity and/or acceleration in a reasonable time and with a single acquisition. They have many parameters that influence the precision of measurements: NS, the number of flow-encoding steps; NEX, the number of signal accumulations; and ND, the number of dimensions. Our aims were to establish a general relationship revealing the precision of these measurements as a function of NS, ND, and NEX and to validate it by experiments using phantoms. Previous work on precision has been restricted to two-step (NS = 2) or 1D (ND = 1) MR velocity measurements. We describe a comprehensive approach that encompasses both multistep and multidimensional strategies. Our theoretical formula gives the precision of velocity and acceleration measurements. It was validated experimentally with measurements on a rotating disk phantom. This phantom was much easier to handle than fluid-based phantoms. It could be used to assess both velocity and acceleration sequences and provided accurate and precise assessments over a wide, adjustable range of values within a single experiment. Increasing each of the three parameters, NS, ND, and NEX, improves the precision but makes the acquisition time longer. However, if only one parameter is to be assessed, maximizing the number of steps (NS) is the most efficient way of improving the precision of measurements; if several parameters are of interest, they should be measured simultaneously. By contrast, increasing the number of signals accumulated (NEX) is the least efficient strategy.

Acceleration↗

Improved estimation of velocity and flow rate using regularized three-point phase-contrast velocimetry.

We improved the three-point phase-contrast method by regularization of MR velocity data after acquisition of a low velocity-to-noise ratio (VNR) velocity image and a high VNR aliased velocity image. The phase unwrapping algorithm is based on the assumed correlation of the velocity of adjacent flow voxels on the low VNR and the unaliased high VNR images. We used Fourier encoding with eight velocity-encoding gradient steps to obtain reference velocity images of the aorta from five subjects (274 images) and compared them with the phase-contrast and three-point phase-contrast images with and without regularization. The VNR of the regularized velocity image was improved by 9.1 dB and the VNR of the three-point phase-contrast velocity image was improved by 0.7 dB with respect to the low first moment velocity image. Corresponding improvements of 9 dB and 3.7 dB were obtained for the estimations of instantaneous flow rate. Magn Reson Med 44:122-128, 2000.

Adult↗

Estimation of pressure gradients in pulsatile flow from magnetic resonance acceleration measurements.

A method for estimating pressure gradients from MR images is demonstrated. Making the usual assumption that the flowing medium is a Newtonian fluid, and with appropriate boundary conditions, the inertial forces (or acceleration components of the flow) are proportional to the pressure gradients. The technique shown here is based on an evaluation of the inertial forces from Fourier acceleration encoding. This method provides a direct measurement of the total acceleration defined as the sum of the velocity derivative vs. time and the convective acceleration. The technique was experimentally validated by comparing MR and manometer pressure gradient measurements obtained in a pulsatile flow phantom. The results indicate that the MR determination of pressure gradients from an acceleration measurement is feasible with a good correlation with the true measurements (r = 0.97). The feasibility of the method is demonstrated in the aorta of a normal volunteer. Magn Reson Med 44:66-72, 2000.

Adult↗

Multidimensional MR mapping of multiple components of velocity and acceleration by fourier phase encoding with a small number of encoding steps.

Previous studies have shown that the multi-step approach of velocity or acceleration encoding is highly efficient in terms of the signal-to-noise ratio per unit time. This work describes a multidimensional extension of this method for simultaneously measuring multiple components of velocity and acceleration with a few encoding steps. N flow dimensions were encoded with an ND-matrix, obtained by combining the various flow-encoding gradients. The small matrix obtained with as few as two encoding steps can be extended by zero-filling in all N dimensions and using ND-Fourier transformation to obtain the maximum of the resulting peak in the ND-matrix, which gives simultaneously all the components of velocity and/or acceleration. The processing time was shortened by using a method of phase computation that gives the same precision as Fourier transformation, but is much faster. A rotating disk was used to show that the velocity-to-noise ratio increases with the number of dimensions acquired, demonstrating the efficiency of multidimensional flow measurements. The feasibility of the method is illustrated by 3D maps of the myocardium velocity, and 2D measurement of velocity and acceleration in the ascending aorta-both obtained by multidimensional phase encoding in volunteers.

Acceleration↗

Spatial regularization of flow patterns in magnetic resonance velocity mapping.

A technique dedicated to spatial regularization of magnetic resonance (MR) velocity data has been implemented to improve flow image quality. It is assumed that neighboring flow-velocity pixels are partially correlated, although large-velocity discontinuities remain possible. Increasing MR signal magnitude due to the in-flow effect also is used to enhance further reliability of the estimated velocity. By using an eight-step Fourier-encoding approach, 162 "reference" velocity images acquired in the ascending aorta from six healthy volunteers were compared with "raw" and "regularized" images that were computed from only two gradient steps. The mean square error decreased from 0.12 m(2) x s(-2) to 0.06 m(2) x s(-2) (P < 10-9) for velocity pixel values and from 1929 ml(2) x s(-2) to 1336 ml(2) x s(-2) (P < 0.01) for instantaneous flow rates. The regularization of two-step data sets provides the same velocity image quality as that found after using three-step data sets without regularization. The method can be applied to phase-velocity data sets of any MR technique to reduce velocity noise. J. Magn. Reson. Imaging 1999;10:851-860.

Adult↗

Pulmonary arterial resistance: noninvasive measurement with indexes of pulmonary flow estimated at velocity-encoded MR imaging--preliminary experience.

Cardiac output and pulmonary vascular resistance (PVR) were measured in 19 patients by means of catheterization of the right side of the heart. Results were compared with the cardiac output and indexes of pulmonary arterial blood flow estimated with velocity-encoded magnetic resonance (MR) imaging. Correlations were good between estimates with right-sided heart catheterization and those with velocity-encoded MR imaging. By providing accurate pulmonary arterial blood flow measurements, velocity-encoded MR imaging allowed distinction of patients with high PVR from subjects with normal PVR.

Adult↗

Acceleration mapping by Fourier acceleration-encoding: in vitro study and initial results in the great thoracic vessels.

Acceleration mapping can be conducted by replacing the bipolar gradient pulse of a velocity mapping sequence by a tripolar pulse. However, since the acceleration encoding pulse is longer, the image quality is altered by the requirement of a long echo time. Since Fourier encoding velocity imaging has been shown to be robust, this velocity mapping method was transformed into an acceleration mapping method. Four steps of the tripolar acceleration encoding gradient pulse were applied successively; acceleration was then obtained by Fourier transform after zero-filling. The accuracy of the method was assessed with a phantom giving a pulsatile flow. Acceleration maps of the ascending aorta and pulmonary artery were obtained in 10 healthy volunteers. The acceleration values measured were in the range of known physiologic values. The feasibility of Fourier encoding acceleration imaging was also demonstrated in four patients.

Adolescent↗

Functional MR imaging of the human sensorimotor cortex during haptic discrimination.

This study attempted to determine whether haptic discriminations of shape (haptic task) activate the same tissue in the central cortical region of normal human subjects as do finger movements (opposition task). Opposition and haptic tasks both activated the central sulcus, as expected from previous imaging studies. The haptic task activated about 50% of the cortical territory activated by the opposition task. The results suggest that exploratory digital movements performed to collect precise somatosensory information and automatic movements performed during finger positioning activate partially overlapping parts of the sensorimotor cortex.

Brain Mapping↗

High resolution T1 weighted magnetic resonance imaging of the deep brain structures using a reduced bandwidth.

High spatial resolution T1 weighted images of the brain were acquired in 5-13 min on a whole-body magnetic resonance imager operating at 1.5 T. In order to obtain 5-8 cm field of view images, the receiver bandwidth (Bw) was lowered to 2 kHz. The use of a 2 kHz Bw, instead of the standard 16 kHz Bw, partially compensated the signal loss due to the small pixel size by increasing the signal-to-noise ratio, without scan time penalty. The chemical shift artifact associated with reduced Bw was not observed because fat signal is negligible in the brain.

Brain↗

[Morphological and functional study of pulmonary arteries by MRI].

This article presents an exhaustive review of MRI in the assessment of the pulmonary arteries (sequences, normal results, clinical signs of the main diseases). Its current preferential indications are: the study of the main pulmonary artery trunks (primary tumours, proximal embolism, caliber abnormalities, anatomical relations with central tumours), the assessment and post-treatment follow-up of pulmonary arterial malformations. Angio-MRI is currently being developed and, in the near future, should allow the reliable diagnosis of pulmonary embolism and will therefore be indicated alongside spiral computed tomography. MRI also allows functional assessment of the right circulation (measurements of circulatory velocity and flow rates). It should rapidly become an examination of choice in the haemodynamic follow-up of patient with pulmonary hypertension and transplant recipients and as an evaluation tool for new drugs.

Humans↗

In vivo hydration profile in skin layers by high-resolution magnetic resonance imaging.

In recent years magnetic resonance imaging has become a very efficient tool for in vivo quantification of water content and water behavior in living tissues. We have applied this technique to the study of the in vivo hydration profile in heel skin layers by quantification of the mobile water proton density versus depth. Effects of a bath, a moisturizer and repeated soaping are present. Hydration profiles by magnetic resonance imaging delineate two different structures in stratum corneum: an outer layer where hydration can be modified by external mechanisms and an inner layer where hydration is not altered. The main interest of this method lies in the fact that the physical signal is exactly located, as spatial encoding is the basis of in vivo imaging. This method differs from other noninvasive methods which acquire an averaged signal from a nondelimited volume of interest.

Administration, Topical↗

Quantification of hemodynamics in primary pulmonary hypertension with magnetic resonance imaging.

The aims of this study were first to analyze pulmonary flow differences between patients with primary pulmonary hypertension (PPH) and volunteers, and second to determine whether magnetic resonance (MR) 3D Fourier encoding velocity imaging is capable of assessing hemodynamics in PPH. Pulmonary and aortic flows were quantified with MR imaging in 13 patients with PPH confirmed by right heart catheterization (RHC) within the same week and in 10 volunteers. MR pulmonary antegrade velocities, acceleration time (defined as the time from the onset of flow to the peak velocity), and arterial distensibility (maximal surface-minimal surface/minimal surface) were significantly different in patients (p < 0.05). MR pulmonary and aortic flow volumes correlated well with each other in the two populations (r = 0.98). Agreement between MR and RHC data was low: for the right cardiac output (mean difference) the 95% confidence interval was -0.88 to -0.22 L/min and for the right stroke volume 2.83 to 9.71 ml. However, the high coefficient correlations found between the two techniques showed that MR data could be used as indicators of right hemodynamics. 3D Fourier encoding-velocity sequence is a reliable noninvasive flow measurement method for the quantification of right hemodynamics in patients with PPH.

Adolescent↗

High-precision MR velocity mapping by 3D-Fourier phase encoding with a small number of encoding steps.

The final result of Fourier velocity mapping is a set of images, each representing the spatial distribution of spins at a given velocity. To acquire data in a short time, the number of encoding gradient steps must be as small as possible, but this can mean sacrificing velocity resolution. We used interpolation methods to obtain high velocity resolution with a small number of encoding steps involving linear interpolation from 16 encoding steps or more and zero-filling interpolation from two to eight encoding steps. Velocity measured by interpolated Fourier-flow encoding agreed well with values obtained using a calibrated phantom. A simulation of noise on the images of the phantom showed that, for a given acquisition time, increasing number of encoding steps in the Fourier flow encoding gave better precision for velocity measurement than did averaging identical signals in phase-mapping methods.

Algorithms↗