PubMed HealthSearch

Biomedical subjects

O Khan

Publications and source records attributed to O Khan.

At least 19 recordsLinked to original sources

Brucellosis of the spine.

Eight cases of spinal brucellosis are included in this study. Diagnosis was established by positive serology. Back pain was the most common complaint. Functional disturbance in walking was observed in three cases; in two others this was because of impairment of cord function. Clinical hepatosplenomegaly was found in one case. Subclinical organomegaly was diagnosed in two other patients. Psoas abscess was identified by computed tomographic scan in two separate cases. Response to drug therapy and surgical decompression, when indicated, resulted in complete recovery in all patients.

Adolescent

Detection of breast cancer by measuring areolar blood flow--a pilot study.

Regional blood flow in the areola was measured by using the non-invasive transient thermal clearance method in normal breasts and in breasts involved with cancer. Areolar blood flow (ABF) in normal breasts was almost constant for women in the age range 20-60y, but decreased at higher ages. ABF in breasts involved with cancer was higher than that in the contralateral breast, and higher than the average normal ABF in the corresponding age group. The effect was more prominent in the left breast. The transient thermal clearance method provides a potential non-invasive means for detection of breast cancer.

Adult

Thermal entrainment methods for studying Raynaud's phenomenon.

Entrainment occurs when an externally applied periodic temperature stimulus forces the peripheral bloodflow component of thermoregulation to oscillate at the same frequency. This phenomenon can be demonstrated using frequency transforms to analyse the spectral content of the bloodflow, and can be used as a diagnostic test for Raynaud's phenomenon. Correlations were performed between the clinical diagnosis and the objective tests. The average inter-clinical correlation coefficient was r = 0.66. When the average clinical diagnosis was compared with a combination of thermal entrainment and digital patency testing the correlation coefficient rose to r = 0.68. These results highlight the difficulties encountered when assessing patients with Raynaud's phenomenon and the necessity of applying both physiological and clinical techniques.

Blood Volume

Ovarian carcinoma follow-up: US versus laparotomy.

Ultrasound (US) was compared with surgical findings in 98 patients with carcinoma of the ovary undergoing follow-up laparotomy after chemotherapy. US had an overall accuracy of 94% in the pelvis, with only small and sheetlike lesions escaping detection. It was more sensitive than clinical examination. Overall accuracy for the liver was 91% with very few false-positive results. For the peritoneal cavity in general, however, accuracy was low, with even large masses escaping detection. Ascites is reliably detected (accuracy of 97%) but is a poor indicator of peritoneal involvement. US is a useful noninvasive complement to laparoscopy in the follow-up of patients with carcinoma of the ovary.

Adult

Repeat pituitary ablation for advanced prostatic cancer.

An elderly male patient with advanced prostatic adenocarcinoma, requiring increasing analgesia, underwent interstitial pituitary irradiation by implantation of yttrium-90. He was temporarily relieved of his pain. Assessment of his anterior pituitary function showed only partial ablation. He therefore underwent a second implantation. This achieved complete ablation, and only when this was achieved did he experience full and sustained pain relief. We recommend assessment of anterior pituitary function in patients treated by pituitary ablation for carcinoma of the prostate, and especially in those in whom the disease progresses after initial success response.

Adenocarcinoma

The appearance of the pyramidal lobe on thyroid scintigraphy.

The standard nuclear medicine textbooks describe the pyramidal lobe of the thyroid as arising from the upper part of the thyroid lobes. Anatomy and surgical texts however describe it as a thyroglossal tract remnant and state that it arises from the isthmus. Review of 150 thyroid scintigrams confirms that on scintigraphy the pyramidal lobe does appear to originate from the upper pole. We have used single photon emission tomography to demonstrate the true origin of the pyramidal lobe by removing overlying thyroid tissue. We suggest that the pyramidal lobe arises from the isthmus and the appearances on scintigraphy are due to the lower part of the lobe being obscured behind the main thyroid lobe.

Humans

High serum prolactin associated with poor prognosis in carcinoma of the prostate.

Seventy patients with carcinoma of the prostate have had regular estimations of serum prolactin levels during a 10-month period, and were followed up for a further 6 months. Of 21 patients who recorded at least one high serum prolactin, 10 (48%) died during these 16 months, while of 50 with normal prolactin, only 2 (4%) died. Ten (21%) of the 47 patients on oestrogen or anti-androgen therapy died, and 9 of these had a high prolactin. This contrasts with 2 (14%) deaths of 14 who had had either bilateral orchiectomy or radiotherapy to the prostate. One of the 2 who died had a high prolactin. It is concluded that an elevated serum prolactin in treated carcinoma of the prostate is associated with progression of the disease and a poor prognosis.

Humans

A clinical evaluation of a prototype positron camera for longitudinal emission tomography.

A multiwire proportional-chamber positron camera, developed at the Rutherford Laboratory, has been evaluated at The Royal Marsden Hospital. The prototype camera consists of two opposing 30 X 30 cm2 chambers. Longitudinal tomograms of a positron-emitting radioactive distribution placed between the detectors are obtained via back-projection and 2D-deconvolution. Due to the limited stereoscopic angle achieved with stationary detectors, only five planes parallel to the detector faces are reconstructed. A selection of images is presented of phantoms using 68Ga and of patients using 18F, 18F fluorodeoxyglucose and Na124I, to illustrate the tomographic performance of the positron camera. A comparison between back-projected and deconvoluted images shows that the 2D-deconvolution process, which includes filtration of image noise, successfully removes the background due to scattered photons. The spatial resolution achieved depends on the half-height frequency cut-off used in the filtering process, and this parameter was chosen according to the count density in the back-projected images. A qualitative visual comparison was made between the positron images and equivalent single photon studies on the same patient. The results justify further development of this new detector, especially for use with generator-produced positron-emitting radionuclides. Three-dimensional deconvolution resulted in improved tomographic performance for phantom data, but was less successful for patient data. These problems associated with limited-angle tomography will be overcome by multi-view acquisition. This study has shown that a relatively low-cost positron imaging system can be used for routine organ imaging. Further developments in hardware and software should yield images which are superior to those from single-photon planar or tomographic studies.

Bone Marrow

Non-invasive imaging techniques in surgery.

In this review article some of the commoner imaging techniques currently available for investigating surgical patients are described. In particular the uses and limitations of ultrasound and radionuclide techniques including emission tomography are discussed.

Abdomen

Combined bipedal lymphangiography, CT scanning and transabdominal lymph node aspiration cytology for node staging in carcinoma of the prostate.

Forty-two patients with carcinoma of the prostate have been studied by bipedal lymphangiography, abdominal CT scanning and percutaneous transabdominal lymph node aspiration cytology to try to increase the accuracy of lymph node staging. The use of two independent radiologists to report the lymphangiograms did not improve the accuracy of reporting. CT scanning was of value only in patients in whom the lymph nodes were not opacified on lymphangiography. Aspiration cytology was positive in 8 of the 40 patients who were studied. There was no morbidity. Six of these 8 patients had MO disease, three had TO tumours and were not on treatment. A poor correlation was found between the presence of lymph node metastases and the Gleason score. Percutaneous transabdominal lymph node aspiration cytology is a safe procedure. When positive, it avoids the need for a staging lymphadenectomy and so helps to identify those patients for whom local treatment is not applicable.

Biopsy, Needle

Testicular venography in impalpable testis.

77 venographic studies of impalpable testes have been reviewed. All patients subsequently underwent surgical exploration. In 28 studies a pampiniform plexus was identified and in 27 a testis was present at the site of the pampiniform plexus. In 20 studies the testicular vein was blind-ending and in only 1 was testicular tissue present at the site of the blind-ending vein. Testicular tissue was absent in the remaining 19. There were 29 technical failures or an inability to identify the full length of the testicular vein because of patent valves. Testicular venography is most useful in localising the position of an impalpable testis but does not determine in all cases whether testicular tissue is present.

Cryptorchidism

Role of ultrasound in the management of ovarian carcinoma.

The ultrasound findings of the pelvis, upper abdomen and peritoneal cavity were correlated with second-look laparotomy in 85 patients with Stage III or Stage IV ovarian carcinoma. High values of accuracy were obtained for the pelvis (90%) and liver (91%) but ultrasound was insensitive to peritoneal disease unless ascites was present.

Adult