PubMed Health⌕ Search

Biomedical subjects

O Lind

Publications and source records attributed to O Lind.

At least 19 recordsLinked to original sources

[Perilymphatic fistula].

BACKGROUND: Perilymphatic fistula is leakage of perilymph from the inner ear to the middle ear. The perilymph surrounds the endolymphatic system in the inner ear (cochlea and the vestibular apparatus) and is most likely a cerebrospinal fluid filtrate. Leakage can occur through the fenestra vestibuli (the oval window), the fenestra cochleae (the round window), or pathological openings in the otic capsule. The cause of perilymphatic fistula can be trauma (barotrauma, head trauma, whiplash injury, iatrogenic trauma during ear surgery or ear syringing), chronic otitis media with cholesteatoma, congenital malformations or idiopathic. MATERIAL AND METHODS: We present 15 patients operated at Haukeland University Hospital from 1980 to 1997. RESULTS: Symptoms and signs are not very consistent, but dizziness and hearing loss are usual. The fistula test has low sensitivity and specificity, and otomicroscopy is not diagnostic. Imaging techniques with CT and MRI are seldom helpful unless in cases of inner ear abnormalities. Surgical exploration of the middle ear can be diagnostic, but even then it may in some cases be difficult to determine if a perilymphatic fistula is present. INTERPRETATION: The treatment of suspected perilymphatic fistula is primarily bed rest with elevated head, and avoidance of straining to facilitate spontaneous closure of a possible fistula. If the symptoms continue, or get worse, surgical exploration is indicated. The results are good regarding dizziness, but more uncertain as far as hearing improvement is concerned. Hearing improvement seems to be negatively correlated with the length of the delay before the fistula is closed.

Adult↗

Alternative distortion product otoacoustic emissions and hearing loss in a clinical population.

Parameters of the alternative distortion product otoacoustic emissions (DPOAEs) 4f1-3f2, 3f1-2f2, 2f2-f1, 3f2-2f1 and 4f2-3f1 as well as the cubic distortion product 2f1-f2 were extracted from the ILO 92 binary files of patients reported on earlier (Lind, 1998). The DPOAEs were recorded at 18 stimulus levels between 19 and 70 dB SPL. The prevalence of at least one valid DPOAE data-point varied from 74% at 4f1-3f2 to 100% at 2f2-f1. The mean number of valid points was six for 2f2-f1, but generally below four for the others. The mean maximum amplitude for the alternative DPOAEs was 6-12 dB below that of the 2f1-f2. The mean maximum signal-to-noise-ratio (SNR) was between 2.5 and 3.5 dB SPL for the four most peripheral emissions and increased to 6.7 dB SPL for the 2f2-f1. As reported earlier, the 2f1-f2 distortion was fairly well correlated with hearing threshold at 2 kHz. The 2f2-f1 shows some correlation with hearing loss at frequencies above f2, but the other DPOAEs were not correlated with hearing loss at any frequency, which may suggest different generating mechanisms and/or sites. The inf1uence of age on maximum amplitude was small but significant for all DPOAEs.

Auditory Threshold↗

A clinical study on the growth of distortion product otoacoustic emissions and hearing loss at 2 kHz in humans.

Growth of distortion product otoacoustic emissions (DPOAE's) at 2 kHz was recorded in 380 human ears with different degrees of hearing loss. Using multiple linear regression analysis, the effect of hearing loss, sex and age on amplitudes and growth rate was evaluated. Hearing loss accounted for approximately one-fifth of the variation in maximum level of DPs and approximately one-fourth of variation in DP threshold. The effect of age was small, but significant. Hearing loss above and below 2 kHz did not influence various DP parameters. Growth rate was generally different for the high and low input level, but correlation was low with age and hearing loss. Various DPOAE response parameters produce too low values of sensitivity and specificity to be used as a predictor for hearing loss at 2 kHz.

Acoustic Stimulation↗

Transient-evoked otoacoustic emissions and contralateral suppression in patients with unilateral tinnitus.

Transient-evoked otoacoustic emissions (TEOAE) have been recorded from 20 patients with unilateral tinnitus and symmetrical hearing up to 2000Hz. Responses were digitally low-pass filtered at 2000Hz. The function of the medial olivocochlear system (MOC) was examined by contralateral acoustic stimulation (CAS) with broadband noise at 50 and 70 dB SPL. Emission amplitude was significantly lower in tinnitus ears in the 10-15ms part of the response. No difference in contralateral suppression of amplitude could be found. The latency shifts were small and were not helpful in separating tinnitus from non-tinnitus ears. Analysis on different parts of the response window may be a useful tool for separating tinnitus from non-tinnitus ears. The lack of efferent effect differences could result from influence of stimuli on tinnitus mechanisms.

Acoustic Stimulation↗

Methodology of comparing three milking clusters in a large dairy herd.

Data for milking parameters were obtained from three different milking clusters using a modified Latin square design to take into account the real milking time regimen of the farm and the time requirements to sort cows. In this modification, cows entered the milking parlor in a random sequence rather than by group. In addition, the clusters were assigned to milking sites. Parameters were compared for 554 cows from one dairy herd that was divided into two smaller herds of 410 and 144 cows. A modified Latin square design was used to compare clusters. The results revealed that 92.1 and 95.5% of cows in Experiments 1 and 2, respectively, were treated by all three clusters; 7.9 and 4.5% of the cows, respectively, were treated by only two clusters; and no cow was treated by only one cluster. The milking parameters for both experiments were in good agreement. Results demonstrated that the modified Latin square design was equivalent to the original Latin square design under the constraint that the number of cows included in one experiment should be > 100 and that the number of milkings should not be < 200 per cluster.

Animals↗

[Hearing loss after erythromycin therapy].

We describe the case of a patient who developed bilateral loss of hearing during intravenous treatment with erythromycin. Predisposing factors may have been reduced renal and hepatic function and treatment with diuretics and aminoglycosides. Recovery was late, but hearing was probably restored to almost pre-treatment level. Patients receiving high doses of erythromycin should, as a routine, be questioned about hearing loss and tinnitus.

Audiometry↗

Teat reactions in cows associated with machine milking.

In the present investigations, referring to conventional milking machines and conventional milking technique, teat ends were transversally compressed for a short moment by means of a cutimeter before, during and after milking (main series), or before and after milking (additional series). The thickness of the teat ends between the jaw plates of the instrument decreased during the high flow-rate phase, increased during the low flow-rate and overmilking phases, and started decreasing as soon as milking was finished. The decreased values in the beginning of the milking process reflect the thinning of the teat wall following the vacuum-induced teat elongation that occurs when the teat cups are attached. The subsequent increased values are due to active, i.e., functionally significant hyperaemia in the teat wall, especially in the specific teat venous system, and locally elevated vascular pressure. Both the thinning and the thickening seem to occur within physiologically tolerable limits. The diagnosis, proposed in the literature, of teat congestion (passive hyperaemia) and/or oedema involving risks of impaired teat and udder health has no support in our investigations.

Animals↗

Spontaneous otoacoustic emissions. Short-time stability.

We have examined 307 spontaneous otoacoustic emissions (SOAEs) from 59 ears. The short-time amplitude stability was very good, especially in the high-frequency region. A statistically significant trend for emissions to influence other emissions could not be demonstrated.

Acoustics↗

[Laryngocele].

We report the cases of five patients with laryngocele. In every case the diagnosis was made by computerized tomography. The laryngocele was internal in two cases, external in one case and combined in the rest. One of the patients had bilateral laryngoceles. The value of CT in the diagnosis is stressed, and it is recommended that this radiologic examination (or MRI) should be performed in patients with otherwise unexplained long-standing hoarseness and attacks of stridorous respiration.

Aged↗

Spontaneous otoacoustic emissions: incidence and short-time variability in normal ears.

More than 50% of normal ears generate spontaneous otoacoustic emissions, which are sinusoidal tones originating in the cochlea. These faint sounds with levels typically at 10 dB to -30 dB are usually not recognized by the subjects who have them, but can be recorded by sensitive microphones in the ear canal. The clinical significance of having or not having spontaneous emissions are at present unknown. The emissions may be useful for non-invasive monitoring of cochlear physiology. A total of 307 spontaneous otoacoustic emissions from 59 ears have been examined. The short-time variability was small when as many as 300 averages were collected. High-frequency emissions showed better stability than low-frequency ones. The ratio of frequency distance between neighboring emissions to critical bandwidth (Bark) was preferentially 0.3-0.5 for lower frequencies and 0.2-0.4 for the higher ones. Amplitude dependence for one emission on its neighbors was difficult to demonstrate. Combination tones (different tones f2-f1 and the cubic distortion product 2 x f1-f2) are probably rare among spontaneous emissions.

Acoustics↗

[Non-organic hearing loss].

Non-organic hearing loss is a condition which must be considered if there is a discrepancy between audiometry and the patient's ability to communicate. Several methods are available for evaluating these patients. In recent years electrophysiological methods have been very useful. We describe eight patients with NOHL, in whom we have found several common characteristics. In most cases the condition recovers spontaneously. Major psychological and social maladjustments have to be excluded. Organic hearing impairment concealed by non-organic hearing loss must not be overlooked.

Audiometry↗

Immediate neurological effects of diving to a depth of 360 metres.

Eighteen divers performed a simulated dive to a depth of 360 metres of seawater breathing a mixture of helium and oxygen. Clinical neurological examinations and neurophysiological tests were performed before and after the dives. Two divers had mild ataxic signs and changed electronystagmography after the dive, and one had impaired vibration sense in one lower extremity. Abnormal EEGs with slow waves and sharp potentials, seen primarily in the temporal regions, occurred in 2 divers. No changes were found in the magnetic resonance imaging brain scans. The divers with evidence of previous central nervous system injury, or a history of unconsciousness or previous decompression sickness seemed more likely to develop neurological signs after these deep dives. This study shows that deep diving may induce immediate neurological changes. We recommend that future deep divers have a neurological examination and 2 separate EEGs included in their medical examinations.

Adult↗

Evoked acoustic emissions in high-frequency vs. low/medium-frequency hearing loss.

Evoked otoacoustic emissions have been recorded from ears with high- and low/medium-frequency hearing losses using a simple technique with fixed stimulus intensity and no suppression of stimulus artifact. Ears with low/medium frequency hearing loss exceeding 40 dB HL generate responses ending before 17.5 ms after stimulus onset. This may be used for testing of low/medium frequency hearing in ears where BRA indicates normal or only slightly impaired high-frequency hearing. Interrelationships between various response parameters and hearing losses have not been demonstrated statistically.

Diagnosis, Differential↗