PubMed Health⌕ Search

Biomedical subjects

O M Ratib

Publications and source records attributed to O M Ratib.

2 recordsLinked to original sources

PET detection of viable tissue in myocardial segments with persistent defects at T1-201 SPECT.

To assess myocardial glucose metabolism and perfusion in 142 myocardial segments with defects seen at thallium-201 single photon emission computed tomography (SPECT), 27 studies with positron emission tomography (PET) utilizing nitrogen-13 ammonia and fluorine-18 deoxyglucose were performed in 26 patients. Myocardial infarction was defined on the basis of concordant reductions in segmental perfusion and glucose utilization; myocardial ischemia, on the basis of preservation of glucose utilization (metabolic viability) in segments with hypoperfusion at rest. Of the 142 segments analyzed, 101 had fixed defects, 31 had partially reversible defects, and ten had completely reversible defects. Preserved glucose utilization was identified in 47 (46.5%) of the segments with fixed defects and 20 (64.5%) of the segments with partially reversible defects. Of the ten segments with completely reversible defects, five (50%) were normal, and five (50%) exhibited ischemia at PET. Visual improvement in a persistent thallium defect at delayed imaging was not associated with residual glucose metabolic activity. Thus, PET can be used to detect glucose metabolic activity in a significant proportion of myocardial segments with fixed or partially redistributing defects seen at thallium SPECT, which suggests that the extent of tissue viability in patients with ischemic heart disease is underestimated at thallium scintigraphy.

Aged↗

Quantitative coronary arteriography: design and validation.

The authors assessed the performance of an automatic and rapid coronary quantification method by evaluating its accuracy in a stenosis phantom. Measurements were obtained with a lucite phantom with 2-, 3-, and 4-mm vessel diameters and concentric stenoses of 33%, 50%, 67%, and 75%. Direct digital angiographic images as well as 10 X 10 spot films and 35-mm cine angiography films were acquired with and without structural noise and mask subtraction. The films were digitized with magnification factors of one and two. An interactive analysis program was used to automatically determine the vessel edges with a Gaussian fit to the cross-sectional density profiles perpendicular to the center line of the vessel. Relative changes of the densitometric cross-sectional area along the vessel were used to assess the percentage of stenosis. Densitometric measurements were comparable in both digital and cine angiograms (r = .99 and r = .98, respectively); however, diameter measurements showed a higher variability and were dependent on the amount of magnification applied to the images.

Absorptiometry, Photon↗