Effects of light fractionation and different fluence rates on photodynamic therapy with 5-aminolaevulinic acid in vivo.

To improve efficacy of photodynamic therapy (PDT) with intravenously administered 5-aminolaevulinic acid (ALA) fractionating the light dose or reducing the light intensity may be a possibility. Therefore, Syrian Golden hamsters were fitted with dorsal skinfold chambers containing an amelanotic melanoma (n=26). PDT was performed (100 mW cm(-2), 100 J cm(-2), continuously or fractionated, and 25 mW cm(-2), 100 J cm(-2); continuously or fractionated) using an incoherent light source following i.v. application of ALA. Following fractionated irradiation, the light was paused after 20 J cm(-2) for 15 min. Prior to and up to 24 h after PDT tissue, pO(2) was measured using luminescence lifetime imaging. The efficacy was evaluated by measuring the tumour volume of amelanotic melanoma cells grown subcutaneously in the back of Syrian Golden hamsters (n=36). Only high-dose PDT resulted in a significant decrease of pO(2). Irrespective of the mode of irradiation only high-dose PDT induced complete remission of all tumours (13 out of 13). It could be shown that low-dose PDT failed to induce a significant decrease of pO(2). No significant effect of fractionated irradiation was shown regarding the therapeutic efficacy 28 days after PDT. Thus performing a fractionated PDT with ALA or reducing the light intensity seems not to be successful in clinical PDT according to the present data.

Aminolevulinic Acid↗

A new type of phosphorescent nanospheres for use in advanced time-resolved multiplexed bioassays.

A new concept to design phosphorescent nanospheres is presented. The spheres are distinguishable by their individual decay time and spectral distribution of their emission spectra. They are composed of a phosphorescent ruthenium metal-ligand complex (MLC) dissolved, along with certain strongly fluorescent cyanine dyes, in modified polyacrylonitrile-based nanospheres. Since the emission spectrum of the MLC overlaps the absorption spectrum of the cyanine and both the MLC (the donor) and the cyanine (the acceptor) are in close spatial proximity, efficient resonance energy transfer (RET) does occur. Thus, the nanospheres emit dual luminescence, one from the acceptor dye and the other from the donor MLC. Variation of the concentrations of the acceptor dye results in a varying efficiency of RET, thus making the spheres distinguishable. Hence, a set of multiplexable sphere labels is obtained by using one MLC (acting as the phosphorescent donor and present in constant concentration) and one acceptor dye (which varies in terms of both spectral properties and concentration). The nanospheres can be identified by the emission maximum (reflecting the kind of acceptor dye) and by decay time (reflecting its concentration). Since the same donor MLC is used throughout, all nanospheres can be excited with the same light source.

Biological Assay↗

Fluorescent imaging of pH with optical sensors using time domain dual lifetime referencing.

We present a referenced scheme for fluorescence intensity measurements that is useful for imaging applications. It is based on the conversion of the fluorescence intensity information into a time-dependent parameter. A phosphorescent dye is added in the form of approximately 10-microm particles to the sample containing the pH-sensitive fluorescent indicator. Both the reference dye and the pH probe are excited simultaneously by a blue LED, and an overall luminescence is measured. In the time-resolved imaging method presented here, two images taken at different time gates were recorded using a CCD camera. The first image is recorded during excitation and reflects the luminescence signal of both the fluorophore (pH) and the phosphor (reference). The second image, which is measured after a certain delay (after switching off the light source), is solely caused by the long-lived phosphorescent dye. Because the intensity of the fluorophore contains the information on pH, whereas phosphorescence is pH-independent, the ratio of the images displays a referenced intensity distribution that reflects the pH at each picture element (pixel). The scheme is useful for LED light sources and CCD cameras that can be gated with square pulses in the microsecond range. The fundamentals and potential of this new method, to which we refer as time domain dual lifetime referencing (t-DLR), are demonstrated.

Journal Article↗

Dual lifetime referencing as applied to a chloride optical sensor.

A membrane with an optical response to chloride has been developed that contains two luminophores that display two largely different decay times. The first luminophore (the "reference") is a chloride-insensitive ruthenium metal-ligand complex possessing a decay time in the microsecond range. The second luminophore is the short-lived chloride-quenchable fluorescent probe lucigenin. Both are contained in a hydrogel matrix and are excited by a blue LED emitting sinusoidally modulated light. Under these conditions, the chloride-dependent fluorescence intensity of lucigenin can be converted in an analyte-dependent fluorescence phase shift that depends on the ratio of the two luminescence intensities and can be measured at modulation frequencies of typically 45 kHz. The dynamic range of this sensor can be adjusted by either varying the ratio of the two luminophores or selecting a particular optical filter combination.

Acridines↗

Fluoro reactants and dual luminophore referencing: a technique to optically measure amines.

An optical sensor for aqueous 1-butylamine is presented which combines two novel techniques: A fluorescent indicator dye (fluoro reactand) embedded in a thin polymer layer performs a reversible chemical reaction with the analyte, causing changes in luminescence intensity. At the same time, inert phosphorescent beads dispersed within the polymer layer provide luminescence signals that act as an internal reference for the indicator dye. As a consequence, the optical sensor is independent of light source fluctuations, ambient light, drifts in optoelectronic setup, or optical fiber bending.

Journal Article↗

Novel diode laser-compatible fluorophores and their application to single molecule detection, protein labeling and fluorescence resonance energy transfer immunoassay.

We describe a series of new long-wave absorbing and fluorescing cyanine dyes and labels (based on a general logic for the design of such dyes), their spectra, covalent and noncovalent linkage to proteins, their use in single molecule detection (SMD) and as donors and acceptors, respectively, in fluorescence resonance energy transfer studies. The new labels represent water-soluble and reactive fluorophores whose quantum yields increase substantially if noncovalently or covalently bound to proteins. Due to their strong absorptions between 550 and 700 nm they are excitable by light-emitting diodes or diode lasers. Their high absorbances (epsilon around 100,000) and adequate fluorescence quantum yields (phi up to 0.68 if bound to proteins) along with their availability as reactive NHS esters make them viable labels for proteins and oligomers, e.g. in context with SMD or fluorescence energy transfer immunoassay which is demonstrated for the system HSA/anti-HSA.

Fluorescent Dyes↗

Red laser-induced fluorescence energy transfer in an immunosystem.

We describe two near-infrared fluorescent squaraine dyes (Sq635 and Sq660), their spectra, their covalent linkage to proteins, and their use as donor and acceptor, respectively, in a fluorescence resonance energy transfer (FRET) immunoassay based on the use of red lasers. The dyes show quantum yields of around 10% in the free form and up to 68% when bound to proteins. If converted into their N-hydroxysuccinimide esters, they can be linked to free amino groups of proteins. To improve water solubility, two sulfo groups were introduced. The emission spectrum of Sq635 overlaps the absorption spectrum of Sq660, a fact that makes them a useful pair of dyes for use in FRET immunoassay which is demonstrated for human serum albumin/anti-human serum albumin.

Antibodies↗

Hydrophilic sensor membrane based on cation-selective protic chromoionophore.

The first potassium optode based on a protic chromoionophore immobilized in a hydrogel matrix is presented. The highly selective protic chromoionophore consists of a cryptohemispherand moiety and a trinitroanilino chromophore part. The acidifying power of potassium ions over sodium ions is 0.6 pH units. This correlates with the findings in solution. In contrast to several crown and aza-crown based chromophores the highly pre-organized moiety allows ion detection even in aqueous environment. The detection limit for potassium ions at pH 7.7 is 5 microM.

Biosensing Techniques↗

Fiber-optic microsensor for high resolution pCO2 sensing in marine environment.

A fast responding fiber-optic microsensor for sensing pCO2 in marine sediments with high spatial resolution is presented. The tip diameter varies typically between 20 and 50 microm. In order to make the pH-indicator 8-hydroxypyrene-1,3,6-trisulfonate soluble in the ethyl cellulose matrix, it was lipophilized with tetraoctylammonium as the counterion [HPTS-(TOA)4]. The microsensor was tuned to sense very low levels of dissolved carbon dioxide which are typically present in marine systems. The detection limit is 0.04 hPa pCO2 which corresponds to 60 ppb CO2 of dissolved carbon dioxide. A soluble Teflon derivative with an extraordinarily high gas permeability was chosen as a protective coating to eliminate interferences by ionic species like chloride or pH. Response times of less than 1 min were observed. The performance of the new microsensor is described with respect to reproducibility of the calibration curves, dynamic range, temperature behavior, long term stability and storage stability. The effect of hydrogen sulfide as an interferent, which is frequently present in anaerobic sediment layers, was studied in detail.

Journal Article↗

Polyaniline-coated microtiter plates for use in longwave optical bioassays.

A technique for coating the wells of microtiter-plates with polyaniline layers and with polyaniline/enzyme layers is presented. The resulting wells are shown to be useful for assaying enzyme substrates (as exemplified for glucose via pH) and hydrogen peroxide (via the redox properties of the film). Analyte detection is based on monitoring the absorption spectra of the polyaniline, which turn purple as a result of redox processes, or green on formation of acids by enzymatic reactions. Hydrogen peroxide (a species produced by all oxidases) and glucose (which yields protons on enzymatic oxidation) have been determined in the millimolar to micromolar concentration range. High sensitivity, film stability and good reproducibility of the measurements make the system an attractive alternative to existing biosensing schemes.

Aniline Compounds↗

Sol-gel based glucose biosensors employing optical oxygen transducers, and a method for compensating for variable oxygen background.

Various types of thin-film glucose biosensors based on the use of the enzyme glucose oxidase (GOx) have been developed. The luminescent oxygen probe Ru(dpp)--whose emission is quenched by oxygen--is used to measure the consumption of oxygen. Three different combinations of oxygen transducer and sol-gel immobilized GOx were tested. In the first, GOx was sandwiched between a sol-gel layer doped with Ru(dpp) and a second sol-gel layer composed of pure sol-gel (the 'sandwich' configuration). In the second, a sol-gel layer doped with Ru(dpp) was covered with sol-gel entrapped GOx (the 'two-layer configuration'). In the third, both GOx and a sol-gel powder containing GOx were incorporated into a single sol-gel phase (the 'powder configuration'). In all cases, it was found to be essential to add sorbitol which results in a more porous sol-gel in which diffusion is not impaired. The sandwich configuration provides the highest enzyme activity and the largest dynamic range (0.1-15 mM), but suffers from a distinct decrease in sensitivity upon prolonged use. The two-layer configuration has the fastest response time (t90 = 50 s), while the 'powder configuration' provides the best operational lifetime. The storage stability of all configurations exceeds 4 months if stored at 4 degrees C. In an Appendix, equations are derived which describe the response of such sensors, how the effect of varying oxygen supply can be compensated for by making use of two sensors, one sensitive to oxygen only, the other to both oxygen and glucose, and how such sensors can be calibrated using two calibrators only.

Biosensing Techniques↗

Cell-type specific protoporphyrin IX metabolism in human bladder cancer in vitro.

5-Aminolevulinic acid (ALA)-supported fluorescence endoscopy of the urinary bladder results in a detection rate of bladder cancer superior to that of white light endoscopy. The different accumulation of the metabolite protoporphyrin IX (PPIX) in tumor cells after ALA instillation is poorly understood; however, it is crucial to optimize diagnosis and potential phototherapy. For systematic analysis of cell-type specific PPIX accumulation and metabolism two human bladder carcinoma cell lines (RT4 and J82), a normal urothelial cell line (UROtsa), and a fibroblast cell line (N1) were chosen, and grown in two different growth states to model important tissue components of the urinary bladder, i.e. tumor, normal epithelium and stroma. To quantitate PPIX content, fluorescence intensities measured by flow cytometry were matched with cellular PPIX extraction values, and related to relative ferrochelatase activity, cellular iron content, number of transferrin receptors per cell and porphobilinogen deaminase (PBGD) activity. For in vitro experiments, the initial correlation of relative flow cytometric and spectrometric measurements of PPIX provides a calibration curve for consequent flow cytometric PPIX quantification. Lower fluorescence of normal cells could be explained by significant differences of ferrochelatase activity and iron content in comparison to tumor cells. However, the content of iron was not related to transferrin receptor content. PBGD activity seemed to play a minor role for the differential accumulation of PPIX in urothelial cells. In conclusion, the in vitro culture of urothelial cells and fibroblasts indicates that the most important metabolic step for PPIX accumulation in the urinary bladder is the transition from PPIX to heme. Further investigation of PPIX metabolism does support the validation of photodynamic diagnosis, and might also lead the way to a highly specific tumor related molecule.

Antigens, CD↗

Composite films of Prussian blue and N-substituted polypyrroles: covalent immobilization of enzymes and application to near infrared optical biosensing.

We demonstrate the feasibility of optical biosensing using a material which, in essence, is a modified inorganic film to which various enzymes were covalently attached. Thin and transparent blue films composed of Prussian blue and incorporated into a network of N-substituted polypyrroles are sensitive to pH in the 5-9 range at 720 nm wavelength and can be modified with enzymes to result in the respective biosensors. Several methods of enzyme immobilization, using bifunctional crosslinking reagents, and various enzymes were tested. The best results were obtained using the one-step carbodiimide method which resulted in highly active, stable and transparent biosensor films for optical determination of urea and acetylcholine. The operational stability exceeded 1 month and even after 2 months of dry storage at room temperature the activity did not drop. The biosensors allow optical determination of the respective substrates in the millimolar concentration range.

Acetylcholinesterase↗

Capacitive monitoring of protein immobilization and antigen-antibody reactions on monomolecular alkylthiol films on gold electrodes.

Self-assembled monolayers of omega-mercaptohexadecanoic acid and omega-mercaptohexadecylamine on gold electrodes are stable at neutral pH and display pure capacitive behavior at frequencies around 20 Hz. Different methods of covalent immobilization of proteins on these monolayers are compared. Various reagents including succinimides, thionylchloride, p-nitrophenol and carbodiimides were used to activate the carboxy groups of the adsorbed monolayer of omega-mercaptohexadecanoic acid. Glutaraldehyde, cyanuric chloride and phenylene diisocyanate were used to activate the amino groups of the monolayer of omega-mercaptohexadecylamine. The immobilization of albumin on the activated surface was studied by capacitive measurements. The N-hydroxysuccinimide and carbodiimide methods were identified as most suitable for protein immobilization in that they did not compromise the insulating properties of the alkylthiol layer and led to maximal increase of its dielectric thickness. These approaches were used for a layer-by-layer preparation of a capacitive immunosensor. Specifically, antibodies to human serum albumin were immobilized on the alkylthiol mono-layer. Binding of the antigen led to a decrease of the electrode capacitance. The detection limit of the immunosensor is as low as 15 nM (1 mg/l).

Alkylation↗

Microalbuminuria and borderline-increased albumin excretion determined with a centrifugal analyzer and the Albumin Blue 580 fluorescence assay.

We report a new automated fluorescence assay for determination of albumin in urine. The dye Albumin Blue 580 specifically binds to albumin with exhibition of strong red fluorescence. The albumin concentration is calculated from emission intensity at 616 nm (excitation at 590 nm) and a calibration curve. Two Cobas Fara programs cover working ranges of 2-200 and 1-50 mg/L with detection limits of 1.4 and 0.4 mg/L, respectively. Within-run CVs (n = 10) ranged from 1.7% (189 mg/L) to 8.9% (7.2 mg/L) for 2-200 mg/L and from 2.9% (43.3 mg/L) to 5.7% (2.3 mg/L) for the 1-50 mg/L range. A test of urine samples (n = 100) submitted to routine analysis gave results that agreed well with those by the Behring nephelometric assay: AB 580 = 0.922 (+/-0.010) BNA + 4.16 (+/-0.78). No interference was detected from other urine components, including several proteins and 46 drugs. The high specificity and sensitivity make the method ideal for determination of microalbuminuria. In addition, the method is fast, inexpensive, and well-suited for clinical laboratory application and thus may be used instead of immunoassays.

Albumins↗

Enzyme biosensor for urea based on a novel pH bulk optode membrane.

A new, absorbance-based enzymatic biosensor membrane for determination of urea is described. A lipophilic, fully LED- and diode laser-compatible pH sensitive dye was incorporated into a plasticized, carboxylated poly(vinyl chloride) membrane and served as the optical transducer of the sensor. Urease was covalently linked to the surface of the pH bulk optode membrane to form a very thin cover. The resulting biosensor membrane allows rapid determination of urea over the 0.3 to 100 mM range. The reproducibility, stability, and effects of pH and buffer concentration on the response of sensor are reported. The preparation of the pH transducer and the immobilization of the enzyme are simple and may easily be adopted to other biosensor types.

Animals↗