PubMed Health⌕ Search

Biomedical subjects

O Salas-Solano

Publications and source records attributed to O Salas-Solano.

8 recordsLinked to original sources

Optimization of high-performance DNA sequencing on short microfabricated electrophoretic devices.

We have examined the parametric performance of short microfabricated electrophoresis devices that operate with a replaceable linear poly(acrylamide) (LPA) solution for the application of DNA sequencing. A systematic study is presented of the dependence of selectivity, separation efficiency, and resolution of sequencing fragments on buffer composition, LPA concentration, LPA composition, microdevice temperature, electric field, and device length. A specific optimization is made for DNA sequencing on 11.5-cm devices. Using a separation matrix composed of 3.0% (w/w) 10 MDa plus 1.0% (w/w) 50 kDa LPA, elevated microdevice temperature (50 degrees C), and 200 V/cm, high-speed DNA sequencing of 580 bases on standard M13mp18 was obtained in only 18 min with a base-calling accuracy of 98.5%. Read lengths of 640 bases at 98.5% accuracy were achieved in approximately 30 min by reducing the electric field strength to 125 V/cm. We believe that this constitutes matrix-limited performance for microdevices of this length using LPA sieving matrix and this buffer chemistry. In addition, it was confirmed, that shorter devices are rather impractical for production sequencing applications when LPA is used as sieving matrix.

Base Sequence↗

Eight hundred-base sequencing in a microfabricated electrophoretic device.

The human genome will be sequenced using capillary array electrophoresis technology. Although currently achieving only 550 base reads per run, capillary arrays have increased the efficiency and lowered the cost of sequencing by eliminating gel plate preparation, reducing sample volumes, and offering automation and speed. However, much higher throughput and greater cost reductions are needed. The next major advancement in sequencing technology is expected from the development of arrays of microfabricated channels in a plate or "chip" format. For de novo sequencing, the practical utility of the microdevice approach has been limited by device length to a read of 500-600 bases per run. We demonstrate a significant milestone for a microfabricated device by obtaining an average read length of 800 bases in 80 min (98% accuracy) for either M13 standards or DNA sequencing samples from the Whitehead Institute Center for Genomic Research (WICGR) production line. This result is achieved in 40-cm-long channels using a new class of large-scale microfabricated devices. Both microfabrication of extended structures and achievement of long reads are essential steps toward a 384-lane very-large-scale microfluidic (VLSMF) system for ultrahigh-throughput DNA sequencing analysis, currently under construction in our laboratory.

Base Sequence↗

Microchip electrophoresis: a method for high-speed SNP detection.

As a trial practical application, we have applied optimized microfabricated electrophoresis devices, combined with enzymatic mutation detection methods, to the determination of single nucleotide polymorphism (SNP) sites in the p53 suppressor gene. Using clinical samples, we have achieved robust assays with quality factors as good as conventional electrophoresis in approximately 100 s. This is 10 and 50 times faster than capillary and slab gel electro-phoresis, respectively. The method was highly accurate with an average error of mutation site measurement of only +/-5 bp. No clean-up of the digestion mixtures was needed prior to injection. This greatly simplifies sample handling relative to capillary instruments, which is important for high-throughput screening applications. Following identification, absolute mutation determination of the screened samples was achieved in a second microdevice optimized for four-color DNA sequencing. Total run time was 25 min in this second device and sequencing data were in full agreement with ABI Prism 377 sequencing runs which required 3.5 h. The tandem application of microdevices for location then full characterization of SNPs appears to confirm many of the improvements claimed for future application of microdevices in practical scaled screening for mutational analysis.

DNA Mutational Analysis↗

Recent developments in DNA sequencing by capillary and microdevice electrophoresis.

The present review covers papers published in the years 1997 and 1998 on DNA sequencing by capillary and microdevice electrophoresis. The article does not include other electrophoretic DNA applications such as analysis of oligonucleotides, genotyping, and mutational analysis. Capillary gel electrophoresis (CGE) is starting to become a viable competitor to slab gel electrophoresis for DNA sequencing. Commercially available multicapillary array sequencers are now entering sequencing facilities which to date have totally relied on traditional slab gel technology. CGE research on DNA sequencing therefore becomes increasingly concerned with the critical task of fine-tuning the operational parameters to create robust sequencing systems. Electrophoretic microdevices are being considered the next technological step in DNA sequencing by electrophoresis.

Coloring Agents↗

Routine DNA sequencing of 1000 bases in less than one hour by capillary electrophoresis with replaceable linear polyacrylamide solutions.

Long, accurate reads are an important factor for high-throughput de novo DNA sequencing. In previous work from this laboratory, a separation matrix of high-weight-average molecular mass (HMM) linear polyacrylamide (LPA) at a concentration of 2% (w/w) was used to separate 1000 bases of DNA sequence in 80 min with an accuracy close to 97% (Carrilho, E.; et al. Anal. Chem. 1996, 68, 3305-3313). In the present work, significantly improved speed and sequencing accuracy have been achieved by further optimization of factors affecting electrophoretic separation and data processing. A replaceable matrix containing a mixture of 2.0% (w/w) HMM (9 MDa) and 0.5% (w/w) low-weight-average molecular mass (50 kDa) LPA was employed to enhance the separation of DNA sequencing fragments in CE. Experimental conditions, such as electric field strength and column temperature, as well as internal diameter of the capillary column, have been optimized for this mixed separation matrix. Under these conditions, in combination with energy-transfer (BigDye) dye-labeled primers for high signal-to-noise ratio and a newly developed expert system for base calling, the electrophoretic separation of 1000 DNA sequencing fragments of both standard (M13mp18) and cloned single-stranded templates from human chromosome 17 could be routinely achieved in less than 55 min, with a base-calling accuracy between 98 and 99%. Identical read length, accuracy, and migration time were achieved in more than 300 consecutive runs in a single column.

Acrylic Resins↗

A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. A. Development of the cleanup protocol.

A method for the cleanup of Sanger DNA sequencing reaction products for capillary electrophoresis analysis with replaceable polymer solutions has been developed. A poly(ether sulfone) ultrafiltration membrane pretreated with linear polyacrylamide was first used to remove template DNA from the sequencing samples. Then, gel filtration in a spin column format (two columns per sample) was employed to decrease the concentration of salts below 10 microM in the sample solution. The method was very reproducible and increased the injected amount of the sequencing fragments 10-50-fold compared to traditional cleanup protocols. Using M13mp18 as template, the resulting cleaned-up single DNA sequencing fragments could routinely be separated to more than 1000 bases with a base-calling accuracy of at least 99% for 800 bases. The method is simple and universal and can be easily automated. In the following paper, a systematic study to determine quantitatively the effects of the sample solution components such as high-mobility ions (e.g., chloride and dideoxynucleotides) and template DNA on the injected amount and separation efficiency of the sequencing fragments is presented.

Base Sequence↗

A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. B. Quantitative determination of the role of sample matrix components on sequencing analysis.

In the previous paper, a sample cleanup procedure for DNA sequencing reaction products was developed, in which template DNA was removed by ultrafiltration and the total concentration of salts (chloride and di- and deoxynucleotides) was decreased below 10 microM using gel filtration. In this paper, a quantitative study of the effects of these sample solution components on the injected amount and separation efficiency of the sequencing fragments in capillary electrophoresis is presented. The presence of chloride and deoxynucleotides in a total concentration above 10 microM in the sample solution significantly decreased the amount of DNA sequencing fragments injected into the capillary column. However, the separation efficiency was not affected upon increasing the amount of salt. On the other hand, in the presence of only 0.1 microgram of template in the sample (one-third of the lowest quantity recommended in cycle sequencing) and at very low chloride concentration (approximately 5 microM), the separation efficiency decreased by 70%, and the injected amount of DNA sequencing fragments was 40% lower compared to the sample cleaned by the new purification method. The deleterious effect of template DNA on the separation of sequencing fragments was suppressed in the presence of salt in a concentration above 100 microM in the sample solution. Separately, it was found that both the electric field strength and duration of injection affected the resolution of DNA sequencing fragments when the cleaned up sample solution was used. Separation efficiencies of 15 x 10(6) theoretical plates/m were achieved when the sample was loaded at low electric field, e.g., 25 V/cm for 80 s or less. The results demonstrate that the sample solution components (chloride, deoxynucleotides, template DNA) and injection conditions must be controlled to achieve high performance and rugged DNA sequencing analysis.

Chlorides↗

Characterization of high molecular mass linear polyacrylamide powder prepared by emulsion polymerization as a replaceable polymer matrix for DNA sequencing by capillary electrophoresis.

In a previous paper, a 2% w/w replaceable high molecular mass linear polyacrylamide solution (high molecular mass LPA) was used to achieve long read-lengths for DNA sequencing by capillary electrophoresis (E. Carrilho et al., Anal. Chem. 1996, 68, 3305-3313). In that work, the polymer was prepared by polymerization in water at 6% w/w, followed by dilution to 2% w/w. In this study, an improved method for preparation of high molecular mass LPA was developed, based on inverse emulsion polymerization. With this polymerization procedure, the LPA results in a molecular mass of approximately 9 MDa, with characteristics of a fine powder of high purity and practically unlimited shelf life. Using size exclusion chromatography (SEC) and viscosity measurements to characterize the polymer, good batch-to-batch reproducibility was found. It was observed that the viscous polymer solutions made from these high molecular mass polymers require careful preparation and handling because the method of dissolution could affect the molecular mass distribution and the resultant separation of DNA components. Solutions containing 2% w/w of LPA made by emulsion polymerization were simple to prepare, resulting in excellent performance as a replaceable matrix for DNA sequencing by capillary electrophoresis. The viscosity of the polymer decreased exponentially when pressure was applied, allowing easy replacement from a capillary using a syringe. With a properly prepared matrix, a read-length of more than 1000 bases in 80 min with an accuracy better than 97%, and better than 99% for the first 800 bases, could be achieved.

Acrylic Resins↗