[Feedback control of muscle relaxation with a varying on-off controller using cisatracurium].

BACKGROUND: Under clinical conditions constant neuromuscular blockade can also be maintained by a simple closed-loop system. However, delayed onset time, non-linearity of the dose-response curve and different sensitivity to muscle relaxants for each patient are limiting factors. METHODS: In 20 patients who underwent elective surgical procedures under continuous propofol/alfentanil anaesthesia and relaxation with cisatracurium, the maintenance of an electromyographically controlled cisatracurium block of 90% was achieved by a varying on-off control system. Using an own computer-aided measuring device, the course of the neuromuscular blockade and deviations from the desired neuromuscular block were registered. RESULTS: Over a period of 64.2+/-14.0 min, neuromuscular block could be controlled on average at a T(1)-level of 10% (90% block). The mean error of the deviation of the obtained neuromuscular blockade from the set-point was -1.6+/-0.9% on average. To maintain this neuromuscular blockade, a dose rate of 1.4+/-0.9 micro g x kg(-1) x min(-1) cisatracurium was necessary. CONCLUSIONS: It can be concluded that a simple closed-loop system allows the safe use of the intermediate term muscle relaxant cisatracurium for the performance of surgical procedures.

Adult↗

[The syringe pump as actuator--a practical application problem of feedback control systems].

Based on a computer simulation programme, the accuracy of the Graseby 3400 syringe pump was tested for its use in a feedback control system of the neuromuscular block. Firstly, a calculation of errors to determine the difference between the target and actual flow rates was carried out. Next, the characteristic curves of the syringe pump were determined under different flow and sampling rates to correct the application software of the feedback controller with a view to obtaining the correct flow rates online. It was discovered that, particularly with short 12 s sampling rates, dose-dependent errors of almost 100% were provable. Therefore, the application of a robust controller and integration of the characteristic curves at the outlet of the controller software are required. For the adoption of syringe pumps in medical feedback control systems, definite determination of the actual infusion quantity using an exact calculation of errors is required. Especially in cases of short sampling rates in combination with low infusion quantities, the syringe pump comes almost to a standstill, which results in extreme differences between target and actual flow rates.

Computer Simulation↗