PubMed Health⌕ Search

Biomedical subjects

O Suess

Publications and source records attributed to O Suess.

At least 19 recordsLinked to original sources

Multimodal protocol for awake craniotomy in language cortex tumour surgery.

BACKGROUND: Intra-operative neurophysiological language mapping has become an established procedure in patients operated on for tumours in the area of the language cortex. Awake cranial surgery has specific risks and patients are exposed to an increased physical and mental stress. The aim of the study was to establish an algorithm that enables tailoring the neurosurgical and anaesthetic techniques to the individual patient. METHOD: A total of 25 patients underwent awake craniotomy for intra-operative language mapping between 1999 and 2004. Following craniotomy under analgesia and sedation without rigid pin fixation of the head, cortical language mapping was performed in the fully co-operative patient. The results of functional magnetic resonance imaging and of cortical language mapping were incorporated into the 3D dataset for neuronavigation. Depending on the functional data and the individual operative risk tumour resection then proceeded either under conscious sedation with the option of subcortical language monitoring or under general anaesthesia. FINDINGS: After cortical language mapping patients are assigned to one of four groups: BACC (Berlin awake craniotomy criteria) I-IV. BACC I (9 patients): adequate functional data+operative risk not increased-->tumour resection in the awake patient; BACC II (4 patients): limited functional data+operative risk not increased-->tumour resection in the awake patient with the option of language monitoring as needed; BACC III (9 patients): adequate functional data+increased operative risk-->tumour resection under general anaesthesia using functional navigation; BACC IV (3 patients): limited functional data+increased operative risk-->tumour resection in the awake patient with the option of language monitoring as needed. We observed less adverse events in group BACC III. No permanent deterioration of language function occurred in this series. CONCLUSIONS: The multimodal protocol for awake craniotomy provides for tumour resection under general anaesthesia in selected patients using functional neuronavigation. Our experience with the algorithm suggests that it is a useful tool for preserving function in patients undergoing surgery of the language cortex while reducing the operative risk on an individual basis.

Adult↗

Motor nerve root monitoring during percutaneous transforaminal endoscopic sequestrectomy under general anesthesia for intra- and extraforaminal lumbar disc herniation.

INTRODUCTION: Percutaneous transforaminal endoscopic sequestrectomy (PTFES) for intra- and extraforaminal lumbar disc herniation (IHLD and EHLD) is usually performed under local anesthesia because the patient's full cooperation is necessary during surgery in order to reduce morbidity. This puts intraoperative stress on both the patient and the surgeon. The present study was performed to assess the safety and efficacy of performing PTFES under general anesthesia using a new protocol with continuous intraoperative neurophysiological monitoring (IOM). PATIENTS AND METHODS: Twenty-five patients with IHLD and/or EHLD were treated by PTFES under general anesthesia without neuromuscular blocking agents. Free-run electromyography (EMG) recordings from characteristic muscles were monitored for the nerve root exiting through the intervertebral foramen at the level of surgery as well as those immediately above and below this level. The recorded potentials were visualized and analyzed on the monitoring screen. Additionally, the EMG activity was played to the surgeon via loudspeakers. RESULTS: EMG-assisted endoscopic sequestrectomy was successfully completed in all 25 cases. Three patients showed complex repetitive discharge patterns already before the actual procedure, but these normalized upon removal of the sequester. Abnormal EMG changes in the form of intraoperative isolated spikes, phasic bursts, or tonic trains were recorded in 17 of the 25 cases. These occurred during placement of the endoscopic working channel in the area of the neuroforamen in 12 cases and during removal of the sequester in 6 cases. Spikes and bursts were evoked by direct contact with the nerve root or indirectly through traction or compression. Tonic discharge patterns, on the other hand, correlated with more severe mechanical stress caused for instance by compression or traction when the nerve root was fixed in the neuroforamen by the sequester. CONCLUSIONS: PTFES under general anesthesia is a safe and easy-to-perform technique for surgical management of intra- and/or extraforaminal lumbar disc herniation if combined with intraoperative neurophysiological monitoring. General anesthesia reduces intraoperative stress to a minimum, so that a larger number of patients may benefit from this minimally invasive procedure in future.

Adult↗

[Sensor-based detection of skull positioning for image-guided cranial navigation under free head mobility].

PURPOSE: Although computer- and image-guided surgical procedures are an improvement of frame-guided stereotaxy, many navigation systems still require rigid fixation of the patient's head throughout the operation. This study describes the clinical application of a technical modification that enables cranial navigation with "free head mobility" using CT and MR images as well as the calculated 3-D reconstruction models. MATERIAL AND METHODS: A sensor-based electromagnetic neuronavigation system was expanded to allow the localization and position monitoring of several sensors within an electromagnetic field. One of these sensors was attached to a dental splint as an additional reference (DRF = dynamic reference frame). Thus, it was possible to determine the position of the sensor-guiding surgical instruments and to record the slightest movement of the cranium as well. This information was then used to continuously adapt the position of the imaging plane and the resultant calculated 3-D reconstructions to the actual position of the cranium. RESULTS: The clinical application of the DRF was tested for different neurosurgical procedures. They included image-guided biopsies and endoscopic interventions using MRI data, transnasal accesses to the base of the skull using CT data and surgical removal of multilocular metastases using data from both imaging modalities. Intracranial target reference points as well as those on the skull were found with a high accuracy to the initial measurement position after arbitrary movement of the patient's head. Thus, navigation was also possible without rigid fixation of the head because of the continuous adaptation of the imaging data on the change in position of the patient's head. CONCLUSION: Based on these first test results, a high clinical potential for DRF application in cranial navigation is to be expected. The aim of DRF is to dispense with the rigid fixation of the patient's head. This increases the application scope of image-guided navigation procedures to include, for example, any bioptic or endoscopic intervention, in which rigid pin fixation of the cranium is not required or desired. For all other procedures, continuous position monitoring by DRF ensures automatic correction of imaging data with mechanical alteration of the head position.

Brain Diseases↗

Camel bite: an unusual type of head injury in an infant.

Small children are predisposed for animal bite wounds in the craniofacial region, because the likelihood of sustaining trunk and extremity injuries increases with height. The clinical picture of animal bite wounds is highly variable. Depending on the dental anatomy of the biting animal, such wounds may range from sharp stitch wounds to extensive lacerations with or without tissue loss. The ears and nose are injured most often because of their exposed location. Nevertheless, depressed skull fractures with injury to the dura and to the brain parenchyma are extremely rare. This case presentation describes the rare case of a craniocerebral camel bite wound (Lackmann stage IV B) in a 3-year-old girl that required immediate neurosurgical management. The neurosurgical management, choice of antibiotic, postoperative treatment, and clinical course are discussed, and background information on camel bite injuries is given.

Animals↗

Prognostic value of improved intraoperative motor evoked potentials. A case report.

UNLABELLED: This unusual case involves intraoperative registration of improved motor evoked potentials accompanied by postoperative improvement of the motor status. CASE REPORT: A 51-year-old patient undergoing surgery for a right postcentral glioma was first submitted to phase reversal of somatosensory potentials for intraoperative localization of the central sulcus. During subsequent monopolar electric stimulation of the precentral gyrus, motor evoked potentials (MEPs) could not be recorded initially but only following extirpation of the tumor fraction in the central sulcus. The amplitudes of the registered potentials increased during the further clinical course. The preoperative arm-preponderant hemiparesis already improved on the first postoperative day. CONCLUSION: This intraoperative electrophysiological observation correlated with the postoperative neurological status, thus documenting functional recovery of the motor system through the intervention.

Anesthesia, Intravenous↗

Clinical evaluation of a new intracranial pressure monitoring device.

BACKGROUND: Continuous monitoring of intracranial pressure (ICP) still plays a key role in the management of patients at risk from intracranial hypertension. Numerous ICP-measuring devices are available. The aim of the present study was to investigate the clinical characteristics and the magnetic resonance imaging (MRI) compatibility of the recently developed Neurovent-P(REHAU AG+CO, REHAU, Germany) ICP monitoring device. METHOD: In a prospective two-center study, a total of 98 patients with severe head injury, subarachnoid haemorrhage, intracerebral haemorrhage, and non-traumatic brain edema underwent intraparenchymal monitoring of ICP using the Neurovent-P. A control group comprising 50 patients underwent implantation of the Camino-OLM-110-4B ICP monitor. The zero drift of the probes was determined before and after the ICP recording period. Technical and medical complications were documented. The MRI compatibility of the Neurovent-P ICP probe was investigated by evaluating artifacts caused by the probe, probe function and temperature changes during MRI, and probe movement caused by the magnetic field. FINDINGS: The mean zero drift was 0.2+/-0.41 mmHg (maximum 3 mmHg) for the Neurovent-P ICP probes and 0.4+/-0.57 mmHg (maximum 12 mmHg) for the Camino-OLM-110-4B ICP probes. No significant correlation was identified between the extent of zero drift following the removal of the probes and the length of monitoring. Intraparenchymal haemorrhage spatially related to the probe occurred in 1 out of 50 (2%) patients with a Camino-OLM-110-4B probe and in 1 out of 98 (1%) with a Neurovent-P. Damage of the probe due to kinking or overextension of the cable or glass fiber occurred in 4 of the 50 (8%) Camino-OLM-110-4B ICP probes and in 5 of the 98 (5%) Neurovent-P probes. On T2-weighted MR images, the Neurovent-P ICP probe induced only small artifacts with very good discrimination of the surrounding tissue. On T1-weighted MR images, there was a good imaging quality but artifact-related local disturbances in signal occurred. There was no temperature change in the Neurovent-P probe and in the surrounding brain tissue during MR imaging. INTERPRETATION: The Neurovent-P ICP measuring system is a safe and reliable tool for ICP monitoring. Handling of the Neurovent-P system is safe when performed properly.

Adolescent↗

Impact of brain shift on intraoperative neurophysiological monitoring with cortical strip electrodes.

BACKGROUND: Intraoperative neurophysiological monitoring has become the standard procedure for locating eloquent regions of the brain. Such continuous electrical stimulation of motor pathways is usually applied by means of flat silicon-embedded electrodes placed directly on the motor cortex. However, shifting of the silicon strip on the cortical surface as well as electrode displacement due to brain shift underneath the electrode can lead to inaccurate recordings not directly caused by intraoperative impairment of the motor cortex or the motor pathways. METHOD: This prospective study was conducted to quantify cortical brain shift during open cranial surgery and to assess its impact on electrode positioning in 31 procedures near the precentral gyrus. Three groups of different lesion volumes were distinguished. Movement of the cortex between opening of the dura and completion of tumor removal as well as cortical electrode shifting were digitally measured and analyzed. FINDINGS: Cortical surface structures evidenced a significantly larger shift (up to 23.4 mm) in comparison to the electrode strips (up to 4.2 mm) in lesions with a volume of over 20 ml. Cortex shifting highly correlated with lesion volume, whereas strip electrode movement was almost unidirectional and did not differ significantly among the three groups. However, the way they were placed (completely on the cortex vs. partly underlying or overlapping the craniotomy borders) affected the magnitude of their intraoperative displacement. As a consequence, 3 of the 31 cases (9.3%) showed a significant change in the recorded motor responses due to intraoperative dislocation of the stimulating electrode. INTERPRETATION: Changes in the location of cerebral structures due to intraoperative brain shift may exert a marked influence on intraoperative neurophysiological monitoring if cortical strip electrodes are used. Therefore, long-term monitoring of the central region requires continuous checking of the position of stimulating electrodes and, if necessary, correction of their location.

Adult↗

Spontaneous bilateral chronic subdural haematoma of the posterior fossa. Case report and review of the literature.

INTRODUCTION: Chronic subdural haematomas of the posterior fossa in adults without a history of trauma are very rare. To our knowledge, only 15 cases have so far been reported in the literature, including those with anticoagulation therapy. A case of spontaneous bilateral infratentorial chronic subdural haematoma associated with anticoagulation therapy in an alive adult is presented and the relevant literature is reviewed. CASE REPORT: A 70 year old female presented with progressive dizziness, vertigo and gait ataxia. She was on anticoagulation therapy for heart disease. Neuro-imaging revealed bilateral infratentorial subdural masses. The subdural masses were suspects for chronic subdural haematomas by neuroradiological criteria. Because of the progressive symptomatology, the haematomas were emptied through burrhole trepanations. Chocolate-colored fluid, not containing clotted components, gushed out under great pressure. The source of bleeding could not be identified. The patient recovered well from surgery, but died 4 months later shortly after admission to another hospital from heart failure. DISCUSSION: The chronic subdural haematomas in this patient may have been due to rupture of bridging veins caused by a very mild trauma not noticed by the patient and possibly aggravated by the anticoagulation therapy. Infratentorial chronic subdural haematoma should at least be a part of the differential diagnosis in elderly patients with cerebellar and vestibular symptomatology even without a history of trauma.

Aged↗

[Cost analysis of intraoperative neurophysiological monitoring (IOM)].

INTRODUCTION: A number of studies demonstrate that a significant reduction of postoperative neurological deficits can be achieved by applying intraoperative neurophysiological monitoring (IOM) methods. A cost analysis of IOM is imperative considering the strained financial situation in the public health services. MATERIAL AND METHODS: The calculation model presented here comprises two cost components: material and personnel. The material costs comprise consumer goods and depreciation of capital goods. The computation base was 200 IOM cases per year. Consumer goods were calculated for each IOM procedure respectively. The following constellation served as a basis for calculating personnel costs: (a) a medical technician (salary level BAT Vc) for one hour per case; (b) a resident (BAT IIa) for the entire duration of the measurement, and (c) a senior resident (BAT Ia) only for supervision. RESULTS: An IOM device consisting of an 8-channel preamplifier, an electrical and acoustic stimulator and special software costs 66,467 euros on the average. With an annual depreciation of 20%, the costs are 13,293 euros per year. This amounts to 66.46 euros per case for the capital goods. For reusable materials a sum of 0.75 euro; per case was calculated. Disposable materials were calculate for each procedure respectively. Total costs of 228.02 euro; per case were,s a sum of 0.75 euros per case was calculated. Disposable materials were calculate for each procedure respectively. Total costs of 228.02 euros per case were, calculated for surgery on the peripheral nervous system. They amount to 196.40 euros per case for spinal interventions and to 347.63 euros per case for more complex spinal operations. Operations in the cerebellopontine angle and brain stem cost 376.63 euros and 397.33 euros per case respectively. IOM costs amount to 328.03 euros per case for surgical management of an intracranial aneurysm and to 537.15 euros per case for functional interventions. Expenses run up to 833.63 euros per case for operations near the motor cortex and to 117.65 euros per case for intraoperative speech monitoring. DISCUSSION: Costs for inpatient medical rehabilitation have increased considerably in recent years. In view of the financial situation, it is necessary to reduce postoperative morbidity and the costs it involves. IOM leads to a reduction of morbidity. The costs for IOM calculated here justify its routine application in view of the legal and socioeconomic consequences of surgery-related neurological deficits.

Algorithms↗

Intracranial image-guided neurosurgery: experience with a new electromagnetic navigation system.

BACKGROUND: The aim of image-guided neurosurgery is to accurately project computed tomography (CT) or magnetic resonance imaging (MRI) data into the operative field for defining anatomical landmarks, pathological structures and tumour margins. To achieve this end, different image-guided and computer-assisted, so-called "neuronavigation" systems have been developed in order to offer the neurosurgeon precise spatial information. METHOD: The present study reports on the experience gained with a prototype of the NEN-NeuroGuard neuronavigation system (Nicolet Biomedical, Madison, WI, USA). It utilises a pulsed DC electromagnetic field for determining the location in space of surgical instruments to which miniaturised sensors are attached. The system was evaluated in respect to its usefulness, ease of integration into standard neurosurgical procedures, reliability and accuracy. FINDINGS: The NEN-system was used with success in 24 intracranial procedures for lesions including both gliomas and cerebral metastases. It allowed real-time display of surgical manoeuvres on pre-operative CT or MR images without a stereotactic frame or a robotic arm. The mean registration error associated with MRI was 1.3 mm (RMS error) and 1.5 mm (RMS error) with CT-data. The average intra-operative target-localising error was 3.2 mm (+/- 1.5 mm SD). Thus, the equipment was of great help in planning and performing skin incisions and craniotomies as well as in reaching deep-seated lesions with a minimum of trauma. INTERPRETATION: The NEN-NeuroGuard system is a very user-friendly and reliable tool for image-guided neurosurgery. It does not have the limitations of a conventional stereotactic frame. Due to its electromagnetic technology it avoids the "line-of-sight" problem often met by optical navigation systems since its sensors remain active even when situated deep inside the skull or hidden, for example, by drapes or by the surgical microscope.

Adult↗

Neurosurgical procedures in Jehovah's Witnesses: an increased risk?

OBJECTIVE: Because of the growing numbers of members worldwide in the sect of Jehovah's Witnesses, the refusal of blood and blood products due to religious reasons is increasingly encountered in clinical practice. As an alternative to blood transfusion, Jehovah's Witnesses accept blood-free volume substitution, and they sometimes accept the intraoperative reinfusion of autologous blood via a so-called cell saver. The aim of this study was to examine whether the refusal of blood transfusion affects the surgical indications for neurosurgery and whether morbidity and mortality rates are higher after neurosurgical interventions in Jehovah's Witnesses. METHODS: The pre-, intra-, and postoperative hemoglobin and hematocrit values as well as coagulation parameters of a group of Jehovah's Witnesses (n = 103) were compared with those of a valid control group. RESULTS: The total intraoperative blood loss during spinal and intracranial surgery in Jehovah's Witnesses was often less than in controls, which suggests a less traumatic surgical procedure. Hemodynamically relevant blood loss occurred in two spinal and four intracranial interventions. The patients were managed without receiving blood transfusions or blood products, although increased time in the intensive care unit and increased convalescence days were necessary. Mean surgical times were 17.5 minutes longer for spinal interventions and 36.7 minutes longer for intracranial interventions than for patients in the control group. This may be attributed to a more careful and thus slower surgical technique and to longer and more extensive hemostasis. The length of hospitalization was 15% longer for Jehovah's Witnesses than for controls. CONCLUSION: The morbidity and mortality rates for Jehovah's Witnesses undergoing neurosurgery were not higher than those of the control group. Thus, it can be concluded that Jehovah's Witnesses did not have a higher risk when microsurgical techniques and extensive anesthetic monitoring were applied during neurosurgery. Because the surgical success rate for Jehovah's Witnesses corresponded to that of the control group, the increase in costs because of longer treatment times is compensated in the long run by avoiding a lengthier illness, sometimes with more expensive conservative therapy.

Adolescent↗

Monitoring of intraoperative motor evoked potentials to increase the safety of surgery in and around the motor cortex.

OBJECT: The repetitive application of high-frequency anodal monopolar stimulation during surgery in or near the motor cortex allows a qualitative and quantitative evaluation of motor evoked potentials (MEPs). Using this method, motor pathways and motor function can be continuously monitored during surgery. METHODS: In this prospective study, 70 patients underwent MEP monitoring during surgery performed in the central region. All procedures were performed after general anesthesia had been induced without the aid of muscle relaxants. The motor pathways were monitored during the entire surgical procedure by repetitive high-frequency anodal monopolar stimulation (frequency 400-500 Hz; train 7-10 pulses; impulse duration 0.2-0.7 msec; and stimulation intensity 16.9 +/- 7.76 mA). The MEPs were continuously evaluated to assess their latency, potential duration, and amplitude. Recorded alterations in these parameters were subsequently correlated with surgical maneuvers and with postoperative neurological deterioration. The monitoring parameters (latency, potential duration, and amplitude) had a broad interindividual range of variation. A correlation between individual intraoperative changes in the potentials and surgical maneuvers or postoperative neurological deterioration was observed in eight cases. A spontaneous shift in latency greater than 15% or a sudden reduction in the amplitude of the potential greater than 80% was considered a warning criterion. In all cases in which there was an irreversible change in latency or a complete loss of potentials were observed, there was postoperative neurological deterioration. CONCLUSIONS: Improved surgical safety can be achieved using intraoperative neurophysiological monitoring procedures. Repetitive stimulation of the motor cortex proved to be a reliable method for monitoring subcortical motor pathways. Changes in MEP latency and MEP amplitude served as warning criteria during surgery and possessed prognostic value.

Adolescent↗

Intracranial haemorrhage following lumbar myelography: case report and review of the literature.

We describe a subacute intracranial subdural haematoma following lumbar myelography. This rare but potentially life-threatening complication has been reported both after lumbar myelography and following lumbar puncture for spinal anaesthesia. We review 16 previously reported cases of intracranial haemorrhage following lumbar myelography, and discuss the pathogenesis. In all reported cases post-puncture headache was the leading symptom and should therefore be regarded as a warning sign.

Cerebral Angiography↗

Intra-operative mapping of the motor cortex during surgery in and around the motor cortex.

The intra-operative use of neurophysiological techniques allows reliable identification of the sensorimotor region, and constitutes a prerequisite for its anatomical and functional preservation. The present prospective study combines monopolar cortical stimulation (MCS) with the recording of phase reversal of somatosensory evoked potentials (SEP-PR) in a protocol for the intra-operative mapping of the motor cortex. Functional mapping of the motor cortex by SEP-PR and MCS was performed in 70 patients during surgery in and around the motor cortex. The central sulcus was identified by SEP-PR. Cortical motor mapping was then performed by monopolar anodal (400 Hz) stimulation. Motor responses were recorded by needle electrodes placed in the muscles of the contralateral extremities. Surgery was performed under general anaesthesia without muscle relaxants. Intra-operative localization of the central sulcus by SEP-PR was possible in 68 patients (97.14%). Motor evoked potentials (MEP) were elicited following MCS in 67 cases (95.7%). In 3 cases no MEP was recorded, not even after maximal stimulation intensity, the central sulcus being localized by SEP-PR only. On the other hand, MCS allowed localizing the motor cortex in the 2 cases with no recordable SEP-PR. Thus, combining SEP-PR and MCS allowed intra-operative localization of the sensorimotor cortex in 100% of the cases.

Adolescent↗

A new cortical electrode for neuronavigation-guided intraoperative neurophysiological monitoring: technical note.

Intraoperative neurophysiological mapping and monitoring of eloquent brain areas can be combined with image-guided localisation to enhance the safety and efficacy of surgical procedures in the motor cortex. We designed a new type of cortical electrode which can be repeatedly placed on the cortical surface and allows accurate and reproducible stimulation by means of a navigation pointer. The newly designed device consists of a monopolar electrode contact for direct cortical stimulation, housed in a holder which allows placement, easy removal, and precise repeated placement of a surgical navigation pointer. It can be used for navigation-guided, high-frequency anodal monopolar cortical stimulation (MCS) for the mapping of eloquent cortex, and for monitoring of motor pathways. While the cortex is stimulated, compound muscle action potentials (CMAP) are recorded from muscles of the contralateral extremities and are assessed both qualitatively and quantitatively. When the device is used in combination with intraoperative navigation, the stimulation sites may optionally be registered or displayed on the system monitor. This allows repeated pinpointing and obviates the need for strip or grid electrodes in the operative field; although such electrodes may be useful for continuous monitoring, they often are in the surgeon's way. In addition, the primary and supplementary motor cortex can be mapped by determining the location of the sites of stimulation on surface-projected images of the cerebral cortex.

Brain Mapping↗

Subdural air limits the elicitation of compound muscle action potentials by high-frequency transcranial electrical stimulation.

High-frequency transcranial electrical stimulation was performed in 8 patients undergoing surgery in the sitting position. Following the opening of the dura of the posterior fossa changes in compound muscle action potentials were observed. These changes were not attributable to surgical manoeuvres at the brain stem or spinal cord, or to anaesthetic changes. In all these cases intraoperative fluoroscopy of the skull revealed a subdural air collection underneath the stimulation electrodes. Such a subdural air collection, not infrequent in patients operated on in the sitting position, limits the application of high-frequency transcranial electrical stimulation as a monitoring technique. It remains unclear if this effect is due to the increasing distance between scalp and cortex and the insulating effect of subdural air, or due to displacement of the motor cortex. The practical importance of this report is derived from the increasing application of intraoperative motor pathway monitoring.

Adult↗