PubMed Health⌕ Search

Biomedical subjects

O Zuloaga

Publications and source records attributed to O Zuloaga.

9 recordsLinked to original sources

Experimental design to optimise the analysis of organic volatile compounds in cow slurry by headspace solid-phase microextraction-gas chromatography-mass spectrometry.

The headspace solid-phase microextraction (HS-SPME) of some odorous organic compounds [volatile fatty acids (VFAs), phenols and indoles] from animal wastes was optimised using an experimental design approach. The variables affecting the HS-SPME process studied were as follows: type of fibre, pH of the slurry (3-7), addition of sodium chloride (0-1 mol L(-1)), sample volume (10-30 mL), exposure time (10-30 min), exposure temperature (25-50 degrees C), desorption time (3-10 min) and desorption temperature (230-310 degrees C). As for the sorbent, three different types of fibres were studied: 50/30 microm divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS), 100 microm PDMS and 85 microm CAR/PDMS. Methylation VFAs was observed when fibres containing PDMS were used. The analytes studied in the optimisation procedure were acetic acid, propanoic acid, butanoic acid, 3-methylbutanoic acid, pentanoic acid, phenol, 4-methylphenol, 4-ethylphenol, indole and skatole (3-methylindole). In order to study the influence of the variables on the responses of the compounds, a Plackett-Burman design was built using the Unscrambler program. The optimisation was carried out using real samples. In order to take into account the matrix effect on the calibration curves, standard solutions were prepared using a purged cow slurry free from the analytes of interest. Repeatability within and among days, accuracy and detection limits were calculated from these calibration curves.

Animals↗

Comparison of solid phase extraction, saponification and gel permeation chromatography for the clean-up of microwave-assisted biological extracts in the analysis of polycyclic aromatic hydrocarbons.

The feasibility of different clean-up procedures was studied for the determination of polycyclic aromatic hydrocarbons (PAHs) in biota samples such as oysters, mussels and fish liver. In this sense, once the samples were extracted--essentially with acetone and in a microwave system--and before they could be analysed by gas chromatography-mass spectrometry (GC-MS), three different approaches were studied for the clean-up step: solid phase extraction (SPE), microwave-assisted saponification (MAS) and gel permeation chromatography (GPC). The main aim of this work was to maximise the recoveries of PAHs and to minimise the presence of interfering compounds in the last extract. In the case of SPE, Florisil cartridges of 1, 2 and 5 g, and silica cartridges of 5 g were studied. In that case, and with oysters and mussels, microwave-assisted extraction and 5 g Florisil cartridges provided good results. In addition, the concentrations obtained for Standard Reference Material (SRM) NIST 2977 (mussel tissue) were in good agreement with the certified values. In the case of microwave-assisted saponification, the extracts were not as clean as those obtained with 5 g Florisil and this fact lead to overestimate the concentration of the heaviest PAHs. Finally, the cleanest extracts were obtained by GPC. The method was successfully applied to mussels, oysters and hake liver, and the results obtained for NIST 2977 (mussel tissue) were within the confidence interval of the certified reference material for most of the certified analytes.

Animals↗

Accelerated extraction for determination of polycyclic aromatic hydrocarbons in marine biota.

A rapid and simple method is proposed for determination of polycyclic aromatic hydrocarbons (PAH) in complex matrices such as marine biota. The method uses sonication, by means of an ultrasonic probe, as a new tool for assisted extraction, coupled with reversed-phase liquid chromatography (RP-LC) with fluorescence detection (FL) for determination of 16 US EPA priority PAH. Separation and detection of the 16 PAH were complete in 45 min by RP-LC with a C18 column and acetonitrile-water gradient elution. Multivariate optimisation of the variables affecting extraction (ultrasound radiation amplitude, sonication time, and temperature of the water-bath in which the extraction cell was placed) was conducted. The accuracy of the method was determined by analysis of a certified reference material and comparison of the results obtained with those from another method (microwave-assisted extraction and GC-MS). The new technique avoids the main problems encountered in the determination of PAH in complex matrices such as marine biota, and no clean-up step is necessary. The method was applied to determination of PAH in estuarine biota samples from the Urdaibai estuary (Biscay, Spain).

Animals↗

Simultaneous microwave-assisted extraction of polycyclic aromatic hydrocarbons, polychlorinated biphenyls, phthalate esters and nonylphenols in sediments.

A new method was developed for the simultaneous extraction of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), phthalate esters (PEs), nonylphenols (NPs) and nonylphenol mono- and diethoxylates (NP1EOs and NP2EOs, respectively) in sediment samples by means of a closed microwave system. The extractions were carried out at 21 psi and 80% of microwave power and 15 ml of acetone were used as the common extraction solvent. The filtered extract was further fractionated in two groups using Florisil cartridges: PAHs and PCBs were eluted with n-hexane:toluene (4:1) and the PEs, NPs and ethoxylates were eluted with ethyl acetate. All the compounds were analysed by gas chromatography-mass spectrometry (GC-MS). In case of PAHs and PCBs, the developed method was validated by comparison of the results obtained for the certified reference material NIST 1944 with the certified values. In the absence of a reference material for phthalate esters and nonylphenols, one sediment sample was extracted twice under the optimal conditions in order to check than an exhaustive extraction of the analytes occurred. This method is currently used in the study of the distribution of those organic contaminants in the estuaries of the Bay of Biscay (Spain).

Acetone↗

Determination of tributyltin in marine sediment: Comité Consultatif pour la Quantité de Matière (CCQM) pilot study P-18 international intercomparison.

The capabilities of National Metrology Institutes (NMIs-those which are members of the Comité Consultatif pour la Quantité de Matière (CCQM)of the CIPM) and selected outside "expert" laboratories to quantitate (C(4)H(9))(3)Sn(+) (TBT) in a prepared marine sediment were assessed. This exercise was sanctioned by the 7th CCQM meeting, April 4-6, 2001, as an activity of the Inorganic Analysis Working Group and was jointly piloted by the Institute for National Measurement Standards of the National Research Council of Canada (NRC) and the Laboratory of the Government Chemist (LGC), UK. A total of 11 laboratories submitted results (7 NMIs, and 4 external labs). Two external laboratories utilized a standard calibration approach based on a natural abundance TBT standard, whereas all NMIs relied upon isotope dilution mass spectrometry for quantitation. For this purpose, a species specific (117)Sn-enriched TBT standard was supplied by the LGC. No sample preparation methodology was prescribed by the piloting laboratories and, by consequence, a variety of approaches was adopted by the participants, including mechanical shaking, sonication, accelerated solvent extraction, microwave assisted extraction and heating in combination with Grignard derivatization, ethylation and direct sampling. Detection techniques included ICP-MS (with GC and HPLC sample introduction), GC-MS, GC-AED and GC-FPD. Recovery of TBT from a control standard (NRCC CRM PACS-2 marine sediment) averaged 93.5+/-2.4% ( n=14). Results for the pilot material averaged 0.680+/-0.015 micro mol kg(-1) ( n=14; 80.7+/-1.8 micro g kg(-1)) with a median value of 0.676 micro mol kg(-1). Overall, performance was substantially better than state-of-the-art expectations and the satisfactory agreement amongst participants permitted scheduling of a follow-up Key comparison for TBT (K-28), a Pilot intercomparison for DBT (P-43), and certification of the test sediment for TBT content and its release as a new Certified Reference Material (HIPA-1) with a TBT content of 0.679+/-0.089 micro mol kg(-1) (expanded uncertainty, k=2, as Sn) (80.5+/-10.6 micro g kg(-1)).

Journal Article↗

MultiSimplex optimisation of the solid-phase microextraction-gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons, polychlorinated biphenyls and phthalates from water samples.

Solid-phase microextraction coupled to GC-MS was optimised for the determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters and polychlorinated biphenyls (PCBs) in water samples. A 30-microm polydimethylsiloxane fiber was immersed in a 30-ml water sample that contained the analytes of interest (PAHs, PCBs and phthalate esters) and the variables studied were extraction time (15-60 min), extraction temperature (30-90 degrees C), desorption time (1-5 min), desorption temperature (220-270 degrees C) and the addition of sodium chloride (0-9 g). The MultiSimplex programme based on the simplex algorithm was used to establish the optimal conditions. MultiSimplex allowed the simultaneous study of the variables mentioned above and considered the answers of all types of compounds studied in this work. Thus, the optimal conditions obtained allowed the simultaneous determination of PAHs, phthalate esters and PCBs. Furthermore, the accuracy and repeatability of the developed method were calculated from water samples spiked at known concentrations of the analytes. Finally, the optimised method was used to analyse water samples from different sampling points of the Urdaibai and Nerbioi-Ibaizabal estuaries (Biscay, Spain).

Gas Chromatography-Mass Spectrometry↗

Optimization and comparison of MAE, ASE and Soxhlet extraction for the determination of HCH isomers in soil samples.

The microwave-assisted extraction (MAE), accelerated solvent extraction (ASE) and Soxhlet extraction of two isomers of hexachlorocyclohexane, alpha-HCH and gamma-HCH, from a polluted landfill soil have been optimized following different experimental designs. In the case of microwave-assisted extraction, the following variables were considered: pressure, extraction time, microwave power, percentage of acetone in n-hexane mixture and solvent volume. When ASE extraction was studied the variables were pressure, temperature and extraction time. Finally, the percentage of acetone in n-hexane mixture and the extraction time were the only variables studied for Soxhlet extraction. The concentrations obtained by the three extraction techniques were, within their experimental uncertainties, in good agreement. This fact assures the possibility of using both ASE and MAE techniques in the routine determination of lindane in polluted soils and sediments.

Journal Article↗

Influence of solvent and soil type on the pressurised fluid extraction of PAHs.

Pressurised fluid extraction (PFE) of polycyclic aromatic hydrocarbons (PAHs) from a certified reference material (CRM) 524 has been firstly optimised following a central composite design. The instrumental parameters of the PFE (pressure, temperature, extraction time and number of solvent cycles) were studied in order to obtain maximum extraction yields. Neither pressure nor extraction time or temperature seemed to have any significant effect on the extraction yield, therefore one extraction cycle was enough to exhaustively extract all the PAHs from CRM 524. Once the instrumental conditions were established, the extraction yields obtained with eight different solvents or solvent mixtures [acetone, dichloromethane, acetonitrile, acetone-dichloromethane (1 + 1 v/v), acetone-isohexane (1 + 1 v/v), isohexane, methanol and toluene] from the CRM 524 were compared and showed that the best recoveries were obtained with acetone-isohexane (1 + 1 v/v). Finally, the effect of sand, silt, clay and the organic matter content of soil was investigated with respect to recovery of PAHs by PFE with different solvents or solvent mixtures for aged soil samples. In this case, eight soils with different sand, silt, clay and organic matter contents were slurry spiked with PAHs and aged for 19 days. Three aliquots of each slurry spiked soil were extracted with the previously mentioned solvents and the results were studied by means of principal component analysis (PCA) of the whole data set (soil composition, solubility parameter of the solvent and recoveries of all PAHs) and partial least squares (PLS). Clay and organic matter content and the squared solubility parameter have the highest correlation with the recovery of PAHs from soil samples.

Environmental Monitoring↗