Technical problems associated with new designs of Guglielmi detachable coils.

BACKGROUND AND PURPOSE: Recently, we experienced several technical problems that were directly related to new designs of Guglielmi detachable coils (GDCs). We herein present cases involving those problems and propose probable causes. METHODS: We reviewed the clinical and angiographic data of 269 consecutive patients with intracranial aneurysms who had been treated with GDCs between May 1996 and October 2001. We focused on newly encountered technical problems: spontaneous premature coil detachment, backward slipping of the coil into the microcatheter lumen after detachment, and undesirable detachment of the coils at the parent artery. The occurrence and clinical consequences of the problems were investigated before and after the introduction of a new GDC (SynerG) design. Additionally, to confirm the potential causal relationship, in vitro observations and simulation tests were performed. RESULTS: Of the 269 patients, 69 underwent embolization between March and October of 2001. Among those, we encountered technical problems in 10 (14.5%) cases. The overall number of events was 12, including spontaneous detachment (n = 5), backward slipping of the coil into the microcatheter lumen after detachment (n = 4), and undesirable coil detachment with a segment of the coil remaining at the parent artery (n = 3). No similar problems occurred among the 200 patients treated during the period between May 1996 and February 2001, when the new design coil had not yet been introduced. In vitro observations suggested that the long and stiff segment of the SynerG coil, especially the SR type, was a highly probable cause of these technical problems. CONCLUSION: Our clinical experience showed a high incidence of technical problems, and in vitro observations suggested that the new GDC designs could be responsible for them. For safe aneurysm treatment, details of embolization techniques should be modified.

Adult↗

Marker alignment for Guglielmi detachable coil embolization: practical considerations.

BACKGROUND AND PURPOSE: Aneurysm embolization is not without risk: numerous technical aspects are considered before, during, and after the procedure. The purpose of this study was to show the position of the detachment zone of a Guglielmi detachable coil (GDC) with respect to the catheter tip for various microcatheters and marker alignments. METHODS: Six types of commonly used microcatheters were tested (Excel-14, Excelsior, FasTracker-10, Prowler-10, Prowler-14, and Rebar-14). First, the catheter markers and the distance from the catheter tip to the distal end of the proximal and distal markers of each catheter were compared. Second, the coil maker was aligned with the catheter marker. Third, the distal 3 cm of the microcatheter was modified by random shaping, with or without steaming. Last, marker alignment was tested with resterilized microcatheters (ethylene oxide gas sterilization). RESULTS: The length of the catheter marker and the distance between the catheter tip and the distal end of the proximal and distal catheter markers varied among the microcatheters. Sometimes, they varied even within the same microcatheter type. When a GDC was advanced until the proximal end of the marker on the delivery wire was exactly distal to the proximal catheter marker, the coil detachment zone was positioned at approximately 1.0 to 1.5 mm outside the catheter tip. Steaming or shaping of the distal 3 cm of the microcatheters resulted in the GDCs protruding more from the catheter tip. Resterilization also had an effect of marker distance shortening. Microcatheters were easily stretched by usual handling, such as removing a shaping mandrel from the catheter tip. CONCLUSION: Our study shows that proper marker alignment is influenced by many factors, including microcatheter type, steaming, shaping, sterilization, and manual handling.

Catheterization↗