PubMed Health⌕ Search

Biomedical subjects

Olgica Bakajin

Publications and source records attributed to Olgica Bakajin.

11 recordsLinked to original sources

Mapping protein collapse with single-molecule fluorescence and kinetic synchrotron radiation circular dichroism spectroscopy.

We have used the combination of single-molecule Förster resonance energy transfer and kinetic synchrotron radiation circular dichroism experiments to probe the conformational ensemble of the collapsed unfolded state of the small cold shock protein CspTm under near-native conditions. This regime is physiologically most relevant but difficult to access experimentally, because the equilibrium signal in ensemble experiments is dominated by folded molecules. Here, we avoid this problem in two ways. One is the use of single-molecule Förster resonance energy transfer, which allows the separation of folded and unfolded subpopulations at equilibrium and provides information on long-range intramolecular distance distributions. From experiments with donor and acceptor chromophores placed at different positions within the chain, we find that the distance distributions in unfolded CspTm agree surprisingly well with a Gaussian chain not only at high concentrations of denaturant, where the polypeptide chain is expanded, but also at low denaturant concentrations, where the chain is collapsed. The second, complementary approach is synchrotron radiation circular dichroism spectroscopy of collapsed unfolded molecules transiently populated with a microfluidic device that enables rapid mixing. The results indicate a beta-structure content of the collapsed unfolded state of approximately 20% compared with the folded protein. This suggests that collapse can induce secondary structure in an unfolded state without interfering with long-range distance distributions characteristic of a random coil, which were previously found only for highly expanded unfolded proteins.

Circular Dichroism↗

Ultrafast gas chromatography on single-wall carbon nanotube stationary phases in microfabricated channels.

The key to rapid temperature programmed separations with gas chromatography are a fast, low-volume injection and a short microbore separation column with fast resistive heating. One of the major problems with the reduction of column dimensions for micro gas chromatography is the availability of a stationary phase that provides good separation performance. In this report, we present the first integration of single-wall carbon nanotubes (SWNTs) as a stationary phase into 100 mum x 100 mum square and 50-cm-long microfabricated channels. The small size of this column with integrated resistive heater and the robustness of the SWNT phase allow for fast temperature programming of up to 60 degrees C/s. A combination of the fast temperature programming and the narrow peak width of small-volume injections that can be obtained from a high-speed, dual-valve injection system allows for rapid separations of gas mixtures. We demonstrate highly reproducible separations of four-compound test mixtures on these columns in less than 1 s using fast temperature programming.

Journal Article↗

Optimization of a microfluidic mixer for studying protein folding kinetics.

We have applied an optimization method in conjunction with numerical simulations to minimize the mixing time of a microfluidic mixer developed for protein folding studies. The optimization method uses a semideterministic algorithm to find the global minimum of the mixing time by varying the mixer geometry and flow conditions. We describe the minimization problem and constraints and give a brief overview of the optimization algorithm. We present results of the optimization, including the optimized geometry and parameter sensitivities, and we demonstrate the improvement in mixing performance with experiments using microfabricated mixers. The dye-quenching experiments of the original and optimized mixer designs show respective mixing times of 7 and 4 mus, a 40% reduction. The new design also provides more uniform mixing across streamlines that enter the mixer. The optimized mixer is the fastest reported continuous flow mixer for protein folding.

Kinetics↗

Bio-assay based on single molecule fluorescence detection in microfluidic channels.

A rapid bioassay is described based on the detection of colocalized fluorescent DNA probes bound to DNA targets in a pressure-driven solution flowing through a planar microfluidic channel. By employing total internal reflection excitation of the fluorescent probes and illumination of almost the entire flow channel, single fluorescent molecules can be efficiently detected leading to the rapid analysis of nearly the entire solution flowed through the device. Cross-correlation between images obtained from two spectrally distinct probes is used to determine the target concentration and efficiently reduces the number of false positives. The rapid analysis of DNA targets in the low pM range in less than a minute is demonstrated.

DNA↗

Fast mass transport through sub-2-nanometer carbon nanotubes.

We report gas and water flow measurements through microfabricated membranes in which aligned carbon nanotubes with diameters of less than 2 nanometers serve as pores. The measured gas flow exceeds predictions of the Knudsen diffusion model by more than an order of magnitude. The measured water flow exceeds values calculated from continuum hydrodynamics models by more than three orders of magnitude and is comparable to flow rates extrapolated from molecular dynamics simulations. The gas and water permeabilities of these nanotube-based membranes are several orders of magnitude higher than those of commercial polycarbonate membranes, despite having pore sizes an order of magnitude smaller. These membranes enable fundamental studies of mass transport in confined environments, as well as more energy-efficient nanoscale filtration.

Journal Article↗

Controlled electrostatic gating of carbon nanotube FET devices.

Carbon nanotube transistors are a promising platform for the next generation of nonoptical biosensors. However, the exact nature of the biomolecule interactions with nanotubes in these devices remains unknown, creating one of the major obstacles to their practical use. We assembled alternating layers of oppositely charged polyelectrolytes on the carbon nanotube transistors to mimic gating of these devices by charged molecules. The devices showed reproducible oscillations of the transistor threshold voltage depending on the polarity of the outer polymer layer in the multilayer film. This behavior shows excellent agreement with the predictions of a simple electrostatic model. Finally, we demonstrate that complex interactions of adsorbed species with the device substrate and the surrounding electrolyte can produce significant and sometimes unexpected effects on the device characteristics.

Biosensing Techniques↗

Functional one-dimensional lipid bilayers on carbon nanotube templates.

Use of biological machines and environments in novel bioinorganic nanostructures is critical for development of new types of biosensors, bio-NEMS devices, and functional materials. Lipid bilayers that mimic a cell membrane have already played an important role in such applications. We present supported lipid bilayers that spontaneously assemble in a continuous nanoshell around a template of a carbon nanotube wrapped with hydrophilic polymer cushion layers. We demonstrate that such 1-D lipid membranes are fluid and can heal defects, even over repeated damage-recovery cycles. A simple diffusion model can describe mobility of lipid molecules in these 1-D nanoshells. These structures could lead to the development of new classes of biosensors and bioelectronic devices.

Biomimetic Materials↗

Femtomole mixer for microsecond kinetic studies of protein folding.

We have developed a microfluidic mixer for studying protein folding and other reactions with a mixing time of 8 mus and sample consumption of femtomoles. This device enables us to access conformational changes under conditions far from equilibrium and at previously inaccessible time scales. In this paper, we discuss the design and optimization of the mixer using modeling of convective diffusion phenomena and a characterization of the mixer performance using microparticle image velocimetry, dye quenching, and Forster resonance energy-transfer (FRET) measurements of single-stranded DNA. We also demonstrate the feasibility of measuring fast protein folding kinetics using FRET with acyl-CoA binding protein.

Acyl Coenzyme A↗

Layer-by-Layer electrostatic self-assembly of polyelectrolyte nanoshells on individual carbon nanotube templates.

Carbon nanotubes have been featured prominently in the nanotechnology research for some time, yet robust strategies for noncovalent chemical modification of the nanotube surface are still missing. Such strategies are essential for the creation of functional device architectures. Here, we present a new general procedure for carbon nanotube modification based on polyelectrolyte layer-by-layer assembly. We have built multilayer structures around individual carbon nanotube bridges by first modifying the nanotube surface with a pyrene derivative followed by layer-by-layer deposition of polyelectrolyte macroions on the nanotube. Transmission electron microscopy and scanning confocal fluorescence microscopy images confirm the formation of nanometer-thick amorphous polymer nanoshells around the nanotubes. These multilayer polyelectrolyte shells on individual carbon nanotubes introduce nearly unlimited opportunities for the incorporation of various functionalities into nanotube devices, which, in turn, opens up the possibility of building more complex multicomponent structures.

Journal Article↗

Single-molecule measurement of protein folding kinetics.

In order to investigate the behavior of single molecules under conditions far from equilibrium, we have coupled a microfabricated laminar-flow mixer to a confocal optical system. This combination enables time-resolved measurement of Förster resonance energy transfer after an abrupt change in solution conditions. Observations of a small protein show the evolution of the intramolecular distance distribution as folding progresses. This technique can expose subpopulations, such as unfolded protein under conditions favoring the native structure, that would be obscured in equilibrium experiments.

Bacterial Proteins↗

Electrodeless dielectrophoresis of single- and double-stranded DNA.

Dielectrophoretic trapping of molecules is typically carried out using metal electrodes to provide high field gradients. In this paper we demonstrate dielectrophoretic trapping using insulating constrictions at far lower frequencies than are feasible with metallic trapping structures because of water electrolysis. We demonstrate that electrodeless dielectrophoresis (EDEP) can be used for concentration and patterning of both single-strand and double-strand DNA. A possible mechanism for DNA polarization in ionic solution is discussed based on the frequency, viscosity, and field dependence of the observed trapping force.

Biophysical Phenomena↗