Predicting postoperative intraocular lens position and refraction.

PURPOSE: To predict the postoperative IOL position and refraction as accurately as possible independent of individualization of the parameters. SETTING: Universitats-Augenklinik, Mainz, Germany, and Vienna, Austria. METHODS: One patient cohort (189 eyes, Vienna) was used to calibrate the prediction method, which was then applied to a second cohort (65 eyes, Mainz). All calculations were based on consistent numerical ray tracing of the pseudophakic eye using the original manufacturer's intraocular lens (IOL) data (radii, thickness, refractive index). A new algorithm to predict IOL position was developed. Ultrasound (US) axial lengths were calibrated relative to partial coherence interferometry (PCI). Corneal radii extracted from topography were checked against radii measured with the IOLMaster (Zeiss) and by Littmann keratometry. RESULTS: Zero mean prediction errors for IOL position and refraction were obtained without adjusting the parameters and with PCI lengths or US lengths calibrated relative to the PCI values. There was no significant loss of accuracy of US data compared to PCI data. Corneal radii extracted from topography were slightly but statistically significantly different from the Littmann values, and they were more accurate than the latter with respect to prediction error. The measured mean central IOL position (distance from posterior corneal surface) for all IOL types was 4.580 mm, a value very close to the mean recalculated from A-constants (4.587 mm). The difference in the individual central IOL position relative to the mean value depended only linearly (ie, no higher orders such as square or cubic are needed) on axial length, with the mean central IOL position as a free parameter. This parameter should be 4.6 +/- 0.2 mm (the same value as independently measured or recalculated) to obtain zero steepness of the prediction error as a function of axial length, producing zero bias for long and short eyes. CONCLUSIONS: Calculation errors from formulas and confusing adjusting parameters can be avoided if calculations and measurements are performed on a clear and simple physical basis. Nevertheless, an individual prediction error, typically 0.5 to 1.0 diopter, seems to be unavoidable.

Adult↗

Effect of accommodation and pupil size on the movement of a posterior chamber lens in the phakic eye.

PURPOSE: Although a posterior chamber phakic intraocular lens provides effective refractive correction of high myopia and hyperopia, mechanical contact between the implantable contact lens (ICL) and the crystalline lens and inadequate aqueous circulation in the prelenticular space could cause subcapsular opacification. To assess whether and to what extent such mechanical contact occurs, changes in the distance between the STAAR Collamer ICL and the crystalline lens under various conditions were investigated. DESIGN: Open pilot study. PARTICIPANTS: Thirteen eyes of 11 myopic and 2 hyperopic patients with a mean age of 38 years (range, 19-53 years) were examined at least 6 months after ICL implantation. METHODS: A noninvasive, high-resolution biometry technique, partial coherence interferometry, was used to measure distance changes between the ICL and the crystalline lens during subjective accommodation, after instillation of pilocarpine, and under changing light conditions. MAIN OUTCOME MEASURES: Mean distance changes from the posterior corneal surface to the ICL, from the posterior corneal surface to the anterior surface of the crystalline lens, and the distance between the ICL and the crystalline lens. RESULTS: In the nonaccommodated state, the mean distance between the ICL and the crystalline lens was 457 microm (range, 123-924 microm). During subjective accommodation, a significant (P<0.01) decrease and, after topical application of pilocarpine, a nonsignificant (P=0.35) decrease of anterior chamber depth was accompanied by a nonsignificant (P = 0.71) reduction of the ICL-crystalline lens distance. Under photopic conditions, a significant mean reduction (P<0.01) of the ICL-crystalline lens distance of -28 microm (range, -16 to -188 microm) was observed. CONCLUSIONS: Partial coherence interferometry biometry enabled noninvasive high-precision investigation of ICL dynamics. No significant changes between the ICL and the crystalline lens were detected during subjective accommodation and after application of pilocarpine. However, under photopic conditions, with constriction of the pupil, the distance between the ICL and the crystalline lens was significantly reduced. This mechanism might cause inadequate aqueous circulation in the prelenticular space and might be one of the causes of subcapsular opacification in some of the eyes after ICL implantation.

Accommodation, Ocular↗

Central corneal thickness measurements with partial coherence interferometry, ultrasound, and the Orbscan system.

OBJECTIVE: To compare the reliability of central corneal thickness measurements (CCT) obtained with partial coherence interferometry (PCI), ultrasound pachymetry, and the Orbscan system. DESIGN: Cross-sectional study. PARTICIPANTS: Twenty healthy subjects with CCT measurements in both eyes. METHODS: The CCT measurements were obtained with PCI, ultrasound pachymetry, and the Orbscan system. In each eye, 2 investigators performed 5 repeated measurements with each pachymetric device. Intraclass correlation coefficients (kappa) were calculated and mean CCT measurements were compared. MAIN OUTCOME MEASURES: The CCT measurements obtained with ultrasound pachymetry, the Orbscan system (Orbtek Inc., Salt Lake City, UT), and PCI. RESULTS: Mean CCT values measured with ultrasound pachymetry were significantly thicker than those measured with PCI (21.5 microm; P<0.001) or the Orbscan system (19.8 microm; P<0.001). The correlation coefficients for the intraobserver variability were 0.999 for PCI measurements, 0.983 for ultrasound pachymetry measurements, and 0.988 for Orbscan system measurements. The correlation coefficients for the interobserver variability were 0.998 for PCI measurements, 0.980 for ultrasound pachymetry measurements, and 0.988 for Orbscan system measurements. There was a slightly better consistency between ultrasound pachymetry and PCI (kappa = 0.96) than between the Orbscan system and PCI (kappa = 0.92) and between ultrasound pachymetry and the Orbscan system (kappa = 0.89). CONCLUSIONS: Partial coherence interferometry was the method with the least intraobserver or interobserver variability. Mean CCT as measured with ultrasound pachymetry was approximately 20 microm thicker than with the Orbscan system and PCI. However, corneal thickness measurements with ultrasound pachymetry and PCI were slightly more consistent than those of the Orbscan system and PCI. This slightly better consistency, however, may be important, especially in corneal refractive surgery.

Adult↗

Laserinterferometric assessment of pilocarpine-induced movement of an accommodating intraocular lens: a randomized trial.

PURPOSE: To measure the axial movement of an accommodating intraocular lens (IOL) induced by ciliary muscle contraction after application of pilocarpine. DESIGN: Randomized, controlled, patient- and examiner-masked trial with intrapatient comparison. PARTICIPANTS AND CONTROLS: One hundred ten eyes of 55 patients with age-related bilateral cataract. METHODS: This study was divided into 3 parts. In the first, the accommodating IOL (1CU) was compared with a 3-piece open-loop acrylic IOL that served as the control. In the second, to assess the effect of capsule fibrosis on the potential accommodating performance of the accommodating IOL, extensive polishing of the anterior capsule with a slit cannula was compared with standard surgery. In the third, the effect of a posterior capsulorhexis was compared with that of standard surgery. Anterior chamber depth (ACD) was assessed with partial coherence interferometry, measured before and after topical application of pilocarpine 2%, and near visual acuity (VA) was evaluated 3 months after surgery. MAIN OUTCOME MEASURE: Pilocarpine-induced change in ACD. RESULTS: The accommodating IOL showed a forward movement under pilocarpine with a median amplitude of movement of -314 microm (95% confidence interval [CI]: -148 to -592), compared with the backward movement of 63 microm (95% CI: 161 to -41) for the open-loop control IOL (P = 0.001). Capsule polishing and a posterior capsulorhexis had no effect on IOL movement with the accommodating IOL. The median near VA with distance correction was 20/60. CONCLUSION: Pilocarpine induced a small but significant forward movement of the accommodating IOL. However, the amount of movement was calculated to result in a refractive change of <0.5 diopters (D) in most patients, reaching 1 D or slightly more in only single cases, with a large variability of movement. Neither polishing of the capsule bag nor a posterior capsulorhexis could enhance the accommodative ability.

Accommodation, Ocular↗

Comparison of posterior capsule opacification between the 1-piece and 3-piece Acrysof intraocular lenses: two-year results of a randomized trial.

PURPOSE: To compare intensity of posterior capsule opacification (PCO) between the 1-piece and 3-piece haptic designs of an open-loop hydrophobic acrylic intraocular lens (IOL). DESIGN: A randomized, patient- and examiner-masked clinical trial with intraindividual comparison. PARTICIPANTS: Fifty-two patients with bilateral age-related cataract (104 eyes). METHODS: Each patient had cataract surgery in both eyes and received a 1-piece Acrysof IOL in one eye and a 3-piece Acrysof IOL in the fellow eye. Follow-up examinations were at 1 week, 1 month, 6 months, 1 year, and 2 years. Patients were examined at the slit lamp, visual acuity (VA) was determined, and standardized high-resolution digital retroillumination images of the posterior capsule were taken. The intensity of PCO was assessed subjectively at the slit lamp and objectively using automated image analysis software. MAIN OUTCOME MEASURE: Posterior capsule opacification score (scale, 0-10). RESULTS: There was no significant difference between IOL styles in best-corrected VA, rhexis/IOL overlap, capsular folds, and amount of anterior capsule opacification during the follow-up period. One year postoperatively, the amount of regeneratory PCO was higher for the 1-piece Acrysof eyes (image analysis software score: 1.3) than for the 3-piece Acrysof eyes (score: 0.9; P = 0.002). However, 2 years postoperatively, there was no significant difference between the 2 IOL styles (1-piece: 1.5; 3-piece: 1.3; P = 0.3). Neodymium:yttrium-aluminum-garnet capsulotomy was not performed in the study. CONCLUSION: One year postoperatively, the 1-piece Acrysof showed slightly more regeneratory PCO than the 3-piece Acrysof. However, 2 years postoperatively, the barrier effect of the 1-piece design was comparable to that of the 3-piece haptic design, with low PCO intensity.

Acrylic Resins↗

Effect of haptic design on change in axial lens position after cataract surgery.

PURPOSE: To compare the postoperative changes in anterior chamber depth (ACD) between single-piece and multipiece AcrySof intraocular lenses (IOLs) (Alcon Laboratories, Inc.) and their effect on the postoperative refractive shift. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This prospective randomized bilateral study with intraindividual comparison comprised 104 eyes of 52 consecutive patients with age-related cataract. All patients had standardized cataract surgery with a temporal self-sealing incision, phacoemulsification, and IOL implantation in the capsular bag. The first 30 patients received a single-piece, 5.5 mm optic IOL (AcrySof SA30) in 1 eye and a multipiece IOL (AcrySof MA30) in the other eye. Another 22 patients received the corresponding 6.0 mm optic models (AcrySof SA60 and AcrySof MA60, respectively). Anterior chamber depth measurements and evaluation of the change in ACD during the first 6 postoperative months were performed using partial coherence laser interferometry. The amount of change in capsulorhexis size during the first 6 postoperative months was assessed using standardized retroillumination photographs. RESULTS: Single-piece IOLs shifted significantly less postoperatively than multipiece IOLs. The multipiece IOLs shifted forward, especially from 1 day to 1 month. The change in the capsulorhexis area was similar between IOL types. CONCLUSIONS: Single-piece AcrySof IOLs shifted minimally after the first postoperative day; therefore, the prescription for spectacles in eyes with this IOL can be obtained soon after surgery.

Anterior Chamber↗

Effect of optic edge design and haptic angulation on postoperative intraocular lens position change.

PURPOSE: To assess the effect of optic edge design and optic-haptic angulation of open-loop intraocular lenses (IOLs) on postoperative axial movement and the final position of the optic by measuring the anterior chamber depth (ACD) during the first postoperative year using partial coherence interferometry (PCI). SETTING: Department of Ophthalmology, Vienna General Hospital, Institute of Medical Physics, University of Vienna, Vienna, Austria. METHODS: In study 1, a 3-piece silicone IOL with nonangulated modified C-loop haptics (MicroSil, Dr. Schmidt) was implanted in 78 eyes of 39 patients; patients were randomized to receive a round-edged optic IOL in 1 eye and a sharp-edged optic IOL in the other eye. The ACD was measured by PCI 1 day, 1 week, 3 months, and 1 year after surgery. In study 2, a foldable, 3-piece acrylic IOL with modified 10-degree angulated J-loop haptics (AcrySof MA60BM, Alcon) was implanted in 32 eyes of 32 patients. The ACD was measured by PCI 1 day, 1 week, and 3 months after surgery. RESULTS: In eyes with a nonangulated silicone IOL, there was a significant postoperative change in ACD with both sharp-edged and round-edged designs (P<.01). There was forward movement of both IOL designs in the first week, with no significant difference between the 2 models. From 1 week to 3 months, there was backward movement of IOLs of both designs, with the sharp-edged IOL moving a significantly greater amount (P<.001). From 3 months to 1 year, IOLs with both optic edge designs moved slightly backward. Sixty-six percent of angulated IOLs showed continuous but variable forward movement and 34%, backward movement. CONCLUSIONS: Optic edge design influenced postoperative axial optic movement and thus had an impact on the development of postoperative refraction (refractive shift, deviation from target refraction). The influence of optic-haptic angulation proved to be significantly greater and more variable than edge design.

Acrylic Resins↗

Short-term effect of dorzolamide hydrochloride on central corneal thickness in humans with cornea guttata.

OBJECTIVE: To investigate the short-term effect of dorzolamide hydrochloride, a topical carbonic anhydrase inhibitor, on central corneal thickness in patients with cornea guttata. DESIGN AND METHODS: In this randomized, placebo-controlled, double-masked, 3-drug crossover study, 20 patients with cornea guttata (mean endothelial cell count, 1321 cells/mm2) and 8 healthy control subjects (mean endothelial cell count, 2483 cells/mm2) were included. Study medications included 2% dorzolamide hydrochloride (Trusopt 2% eye drops; Merck & Co Inc, Whitehouse Station, NJ), 0.9% saline solution (saline placebo), and a solution identical to the carrier substance of dorzolamide in Trusopt (carrier placebo). The study drugs were applied 4 times per day for 1 day only. Central corneal thickness measurements were performed using partial coherence interferometry on every study day at baseline and after 24 hours of study medication treatment. MAIN OUTCOME MEASURES: Change in central corneal thickness. RESULTS: The mean thickening in central corneal thickness within 24 hours in eyes with cornea guttata treated with dorzolamide, saline placebo, and carrier placebo was 12.0 micro m (95% confidence interval [CI], 7.0-17.1 microm), 0.6 micro m (95% CI, -1.0 to 2.2 microm), and 1.3 micro m (95% CI, -0.1 to 2.6 microm), respectively. CONCLUSION: Application of dorzolamide for 1 day results in a slight but statistically significant thickening of central corneal thickness in patients with cornea guttata.

Administration, Topical↗

Enhanced visualization of macular pathology with the use of ultrahigh-resolution optical coherence tomography.

OBJECTIVES: To demonstrate a new generation of ophthalmic optical coherence tomography (OCT) technology with unprecedented axial resolution for enhanced imaging of intraretinal microstructures and to investigate its clinical feasibility to visualize intraretinal morphology of macular pathology. METHODS: A clinically viable ultrahigh-resolution ophthalmic OCT system was developed and used in clinical imaging for the first time. Fifty-six eyes of 40 selected patients with different macular diseases including macular hole, macular edema, age-related macular degeneration, central serous chorioretinopathy, epiretinal membranes, and detachment of pigment epithelium and sensory retina were included. OUTCOME MEASURES: Ultrahigh-resolution tomograms visualizing intraretinal morphologic features in different retinal diseases. RESULTS: An axial image resolution of approximately 3 micro m was achieved in the eyes examined, nearly 2 orders of magnitude better than conventional ophthalmic ultrasound. Ultrahigh-resolution OCT images provided additional diagnostically important information on intraretinal morphologic features that could not have been obtained by standard techniques. CONCLUSIONS: Ultrahigh-resolution ophthalmic OCT enables unprecedented visualization of intraretinal morphologic features and therefore has the potential to contribute to a better understanding of ocular pathogenesis, as well as to enhance the sensitivity and specificity for early ophthalmic diagnosis and to monitor the efficacy of therapy. This study establishes a baseline for the interpretation of ultrahigh-resolution ophthalmic OCT imaging of macular diseases.

Adult↗

Comparison of 4 methods for quantifying posterior capsule opacification.

PURPOSE: To compare the results of posterior capsule opacification (PCO) quantification and the repeatability of a fully automated analysis system (Automated Quantification of After-Cataract [AQUA]) with that of 2 other quantification methods and subjective grading of PCO. A test set of digital retroillumination images of 100 eyes with PCO of varying degrees was used. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: One hundred digital retroillumination images of eyes (100 patients) with PCO were selected to attain an even distribution from mild to severe cases. The images were evaluated by 4 methods: subjective grading by 4 experienced and 4 inexperienced examiners, the subjective Evaluation of Posterior Capsular Opacification (EPCO) system, posterior capsule opacification (POCO) software, and the AQUA system. Ten images were presented twice to assess the reproducibility of the analysis systems. RESULTS: Subjective grading correlated best with the subjective EPCO system and the objective AQUA system (r = 0.94 and r = 0.93, respectively). The POCO system showed very early saturation and therefore a much weaker correlation (r = 0.73). The POCO scores reached the maximum of 100% in several minimal to mild PCO cases. The reproducibility of the AQUA software was perfect and that of the other analysis systems, comparably satisfactory. CONCLUSION: The objective AQUA score correlated well with subjective methods including the EPCO system. The POCO system, which assesses PCO area, did not adequately describe PCO intensity and includes a subjective step in the analysis process. The AQUA system could become an important tool for randomized masked trials of PCO inhibition.

Cataract↗

Intraocular lens movement caused by ciliary muscle contraction.

PURPOSE: To investigate intraocular lens (IOL) movement, measured as a change in anterior chamber depth (ACD) caused by pilocarpine-induced ciliary muscle contraction. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: In this prospective study, the ACD was measured using high-precision, high-resolution, dual-beam partial coherence interferometry in 62 pseudophakic eyes of 55 patients under pilocarpine- and cyclopentolate-induced ciliary muscle contraction and relaxation. The following were studied: 2 models of a ring-haptic IOL (designed to accommodate), a plate-haptic IOL, and 3 types of 3-piece IOLs. Measurements were performed 3 months after surgery. RESULTS: The ring-haptic IOLs and plate-haptic IOL showed a forward movement (ring haptic 43A, -116 microm; ring haptic 43E, -222 microm; plate haptic -162 microm). The 3-piece IOLs showed no change in ACD except in 1 IOL type in which there was backward movement (156 microm). CONCLUSIONS: Pilocarpine-induced ciliary muscle contraction caused forward movement of ring- and plate-haptic IOLs that resulted in an estimated accommodative amplitude of less than 0.50 diopter in most cases. The accommodating ring-haptic IOLs did not perform better than the conventional plate-haptic IOL.

Accommodation, Ocular↗

Corneal endothelial cell protection with a dispersive viscoelastic material and an irrigating solution during phacoemulsification: low-cost versus expensive combination.

PURPOSE: To evaluate the protective effect on corneal endothelial cells of a low-cost and an expensive combination of a dispersive viscoelastic material and an irrigating solution during phacoemulsification. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This prospective randomized examiner- and patient-masked study comprised 90 eyes of 45 consecutive patients with age-related cataract in both eyes. For each patient, the first eye was randomly assigned to receive hydroxypropyl methylcellulose 2% (Ocucoat) and Ringer's solution (low-cost combination) or sodium chondroitin sulfate 4%-sodium hyaluronate 3% (Viscoat) and an enriched balanced salt solution (BSS Plus) (expensive combination) during phacoemulsification. The contralateral eye received the other treatment. Endothelial cell function was evaluated by measuring corneal thickness (CT) using partial coherence interferometry, morphology assessment, and endothelial cell counts. RESULTS: The acute postoperative increase in CT was +9.8 microm in the low-cost group and +10.9 microm in the expensive group; the difference between groups was not significant. After 1 month, the CT still differed significantly from baseline in the low-cost group. Three months after surgery, the CT had returned to baseline values in both groups. There was no significant between-group difference in endothelial cell counts or morphology. CONCLUSIONS: During phacoemulsification in a nonselected patient population, there was no difference in acute postoperative corneal edema and endothelial cell morphology after 3 months between a Viscoat and BSS Plus combination and an Ocucoat and Ringer's solution combination. Eyes receiving the expensive combination had marginally faster recovery of corneal swelling by 3 months. However, the cost of Viscoat and 500 mL BSS Plus is 5 times that of Ocucoat and Ringer's solution.

Aged↗

After-cataract in adults with primary posterior capsulorhexis: comparison of hydrogel and silicone intraocular lenses with round edges after 2 years.

PURPOSE: To evaluate the potential of primary posterior continuous curvilinear capsulorhexis (PCCC) to prevent after-cataract 2 years after surgery and perform a bilateral comparison of 2 intraocular lens (IOL) materials, silicone and hydrogel. SETTING: Department of Ophthalmology, University of Vienna, Medical School, Vienna, Austria. METHODS: In this randomized patient- and examiner-masked study, 37 patients (74 eyes) with age-related cataract had bilateral small-incision cataract surgery with PCCC. Randomly, 1 eye received a hydrogel IOL and the contralateral eye, a silicone IOL. Both IOLs had open-loop haptics and a round-edged optic. Standardized digital retroillumination photographs were taken 1 day and 1, 6, 12, and 24 months after surgery to evaluate development of after-cataract on the anterior and posterior capsules by subjective grading. Opacification of the PCCC area was also objectively evaluated using new software. RESULTS: Twenty-nine patients (58 eyes) completed the 2-year follow-up. Partial closure with ongrowth at the edge of the PCCC was found in 55% in the hydrogel group and 28% in the silicone group. Total closure of the PCCC was observed in 3 eyes, 2 in the hydrogel group and 1 in the silicone group. CONCLUSION: Ongrowth onto the PCCC area was dependent on IOL material. Because of less ongrowth and more fibrotic after-cataract with silicone IOLs, the efficacy of the PCCC was higher in this group.

Aged↗

Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes.

PURPOSE: To compare anterior chamber depth (ACD) measurements in phakic and pseudophakic eyes using a slit-beam photographic technique (IOLMaster, Carl Zeiss Meditec AG) with those obtained with the laboratory prototype version of partial coherence interferometry (PCI) and with conventional applanation ultrasound in phakic eyes. SETTING: Department of Ophthalmology, Vienna General Hospital, Vienna University, Vienna, Austria. METHODS: Thirty-three ACDs of 28 patients with age-related cataract were measured preoperatively with a slit-beam photographic technique (IOLMaster) and the prototype version of PCI. In 24 eyes, the ACD was also assessed with applanation ultrasound. In addition, 34 ACDs of 18 pseudophakic patients in a different study population were examined postoperatively with the IOLMaster and PCI. RESULTS: The median ACD in the phakic eyes was 3.06 mm (range 1.93 to 3.90 mm) with the IOLMaster, 3.09 mm with PCI (range 1.49 to 4.06 mm), and 2.87 mm (range 2.18 to 3.33 mm) with applanation ultrasound. The precision was 0.005 mm for PCI and 0.015 mm for IOLMaster measurement. The median difference between the IOLMaster and PCI ACD biometry was 0.01 mm +/- 0.14 (SD) (range -0.44 to 0.17 mm) (P =.71). In pseudophakic eyes, the 2 methods showed a median difference of -0.22 mm (range -0.45 to 1.99 mm) (P >.1) and did not correlate (r = 0.21; P >.2). CONCLUSIONS: In phakic eyes, the difference between IOLMaster and PCI measurements was small and not statistically significant. In pseudophakic eyes, the difference was larger and the methods did not correlate.

Anterior Chamber↗

Effect of a fixed dorzolamide-timolol combination on intraocular pressure after small-incision cataract surgery with Viscoat.

PURPOSE: To evaluate the effect of a fixed dorzolamide-timolol combination (Cosopt) on intraocular pressure (IOP) after small-incision cataract surgery with sodium chondroitin sulfate 4%-sodium hyaluronate 3% (Viscoat). SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This prospective randomized study comprised 76 eyes of 38 patients scheduled for small-incision cataract surgery in both eyes. Patients were randomized to receive 1 drop of the fixed dorzolamide-timolol combination in 1 eye or no treatment (control) immediately after cataract surgery. The fellow eye received the other assigned treatment. Cataract surgery was performed with Viscoat in an identical fashion in both eyes. The IOP was measured preoperatively and 6 hours, 20 to 24 hours, and 1 week postoperatively. RESULTS: Six hours after surgery, the mean increase in IOP was significantly lower in the dorzolamide-timolol group than in the control group (4.3 mm Hg +/- 5.6 [SD] versus 8.4 +/- 6.1 mm Hg; P =.003). Two eyes in the dorzolamide-timolol group and 9 in the control group had IOP spikes of 30 mm Hg or higher (P =.022). Twenty to 24 hours after surgery, the mean IOP change was -2.6 +/- 3.3 mm Hg in the dorzolamide-timolol group and 1.5 +/- 3.2 mm Hg in the control group (P<.001). CONCLUSIONS: The fixed dorzolamide-timolol combination was effective in reducing IOP 6 hours and 20 to 24 hours after cataract surgery. However, it did not prevent Viscoat-induced IOP spikes of 30 mm Hg or higher.

Aged↗

Postoperative change in effective lens position of a 3-piece acrylic intraocular lens.

PURPOSE: To study the change in postoperative position of an angulated, 3-piece, foldable acrylic intraocular lenses (IOLs) and evaluate the effect of a sharp posterior optic edge compared with that of a round optic edge on the change in postoperative anterior chamber depth (ACD). SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This randomized intraindividual-comparison study comprised 104 eyes of 52 patients with age-related cataract. Patient received a sharp-edged Sensar OptiEdge AR40e IOL (Allergan Surgical) in 1 eye and a round-edged Sensar AR40 IOL in the other eye. Postoperative follow-up included ACD measurement by partial coherence interferometry and evaluation of the capsulorhexis area by standardized retroillumination photography at 1 day, 1 week, and 1 and 6 months. RESULTS: A decrease in ACD during the first postoperative week was followed by a small increase in ACD during the first 6 months. There was no significant difference between the sharp-edged group and the round-edged group. CONCLUSIONS: The angulated 3-piece acrylic IOLs showed significant forward movement over the first postoperative 6 months. Although the change in refraction was small, there was variability among patients. The sharp posterior optic edge design did not affect the IOL's movement in the capsular bag.

Acrylic Resins↗

Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery.

PURPOSE: To compare measurements performed with the IOLMaster (Carl Zeiss, Meditec AG) with those obtained by applanation ultrasound (US) and manual keratometry and to evaluate the effect of operator experience on US biometry. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: The axial length (696 eyes) and anterior chamber depth (ACD) (462 eyes) were measured in 377 patients with cataract using the IOLMaster and applanation US. To assess the effect of operator experience on the biometric results, the operators were divided into 2 groups: experienced and less experienced in performing US biometry. The difference in measurements between the methods and the variability of the difference were compared between the 2 groups. RESULTS: Applanation US measured axial length and ACD shorter than the IOLMaster; the mean numerical difference was 0.13 mm and 0.19 mm, respectively (P<.01). For axial length, the absolute difference was smaller with experienced operators than with less experienced operators (0.15 mm versus 0.22 mm) (P<.01). For ACD, experienced operators obtained a smaller difference between measurement techniques (0.21 mm versus 0.29 mm; P<.05). CONCLUSIONS: Experienced US operators had less difference and lower variability in the difference between applanation US and IOLMaster readings for axial length and ACD measurements. The noncontact optical method, which is essentially operator independent, gave significantly more reliable biometry before cataract surgery, especially in the case of less experienced operators.

Adult↗

Influence of intraocular lens material on regeneratory posterior capsule opacification after neodymium:YAG laser capsulotomy.

PURPOSE: To evaluate the influence of a neodymium:YAG (Nd:YAG) laser capsulotomy on the morphology and development of regeneratory opacification of the remaining surrounding posterior capsule. SETTING: Department of Ophthalmology, Medical School, University of Vienna, Vienna, Austria. METHODS: Standardized digital retroillumination photographs were taken immediately before and after Nd:YAG laser capsulotomy and at 1 week, 6 months, and 1 to 3 years in 38 eyes of consecutive patients. Changes in regeneratory posterior capsule opacification (PCO) and opacification around the capsulotomy opening were evaluated. The influence of the type of intraocular lens (IOL) material and design (acrylic, n = 8; hydrogel, n = 8; silicone open loop, n = 11; silicone plate haptic, n = 6; poly(methyl methacrylate) [PMMA], n = 5) was assessed. The state of the anterior vitreous surface was examined at the slitlamp in all eyes. RESULTS: In 8 of 17 eyes with a silicone IOL, reduced regeneratory PCO was observed. Massive pearl formation on the margin of the Nd:YAG capsulotomy was typical with silicone IOLs (8 eyes) but also occurred with PMMA IOLs. Eyes with acrylic IOLs had no change in regeneratory PCO after the capsulotomy. Three of 8 eyes with hydrogel IOLs had complete closure of the posterior capsulotomy opening. CONCLUSIONS: Neodymium:YAG laser capsulotomy induced changes in the development and morphology of regeneratory PCO. Silicone and PMMA IOLs led to significant pearl formation on the capsulotomy margin, often combined with a reduction of peripheral regeneratory PCO (silicone). Hydrogel IOLs led to a higher incidence of reclosure of the Nd:YAG capsulotomy opening.

Acrylic Resins↗