PubMed Health⌕ Search

Biomedical subjects

Oliver Speck

Publications and source records attributed to Oliver Speck.

15 recordsLinked to original sources

Systematic investigation of balanced steady-state free precession for functional MRI in the human visual cortex at 3 Tesla.

Previous studies have applied balanced steady-state free precession (bSSFP) to functional brain imaging. Methods that exploit the strong frequency dependence of the MR signal in the bSSFP transition band are strongly affected by field inhomogeneity and frequency drifts. Recent bSSFP studies using "on-resonance" (in the bSSFP passband) acquisition claimed that higher sensitivity was achieved compared to traditional fMRI methods. However, the contrast mechanism that generates activation-related signal changes in bSSFP imaging is not yet fully understood. We performed a systematic study of on-resonance bSSFP signal behavior using a multiecho balanced SSFP sequence with different TRs at 3 Tesla. We conclude that intravoxel dephasing, or the off-resonance averaged steady state, dominates the bSSFP signal decay and determines the bSSFP fMRI contrast. Experimental findings were confirmed by simulations based on existing theories for signal formation around blood vessels in inhomogeneous tissues. The activation-induced signal change in on-resonance bSSFP increases with TE, and the TE dependence of the contrast-to-noise ratio (CNR) in bSSFP is similar to that in gradient echo-planar imaging (GE-EPI). However, GE-EPI has a significantly higher CNR efficiency.

Adult↗

Fast chemical shift mapping with multiecho balanced SSFP.

OBJECT: A method is proposed that provides spectroscopic images with high spatial resolution and moderate spectral resolution at very short total data acquisition times. MATERIALS AND METHODS: Balanced steady-state free precession (bSSFP, TrueFISP, FIESTA, b-FFE) is combined with a multiecho readout gradient and frequency-sensitive reconstruction such as Fourier reconstruction known from echo-planar spectroscopic imaging (EPSI) or matrix inversion. Balanced SSFP imaging requires short repetition times to minimize banding artefacts, thereby restricting the achievable frequency resolution. RESULTS: Two-dimensional (2D) high-resolution spectroscopic images were produced of three 1H resonances (water, acetone and fat) on phantoms and water/fat separation in vivo within 1-2 s. Additionally, fast 31P spectroscopic images were acquired from a phantom consisting of two resonances within 195 ms. CONCLUSION: Frequency-sensitive reconstruction of multiecho bSSFP data can provide spectroscopic images with high spatial and temporal resolution while the frequency resolution is moderate at around 100 Hz. The method can also separate more than three resonances, allowing for hetero-nuclei metabolite mapping, for example 13C and 31P.

Carbon Radioisotopes↗

MR-Encephalography: Fast multi-channel monitoring of brain physiology with magnetic resonance.

A new approach to measure activation-related changes in the brain by magnetic resonance is described offering high temporal resolution of 10-100 measurements per second. This is achieved by simultaneous multi-channel reception where the spatial resolution during continuous observation is determined by the sensitive volume of each coil alone without any additional spatial encoding gradients. Experimental results demonstrate the very high sensitivity of this approach, which allows to directly measure and monitor the stimulus-dependent hemodynamic response as well as ECG- and breathing-related signal fluctuations. One-dimensional spatial encoding either parallel or orthogonal to the cortex demonstrates that vascular signals can be identified by the pronounced signal variation at the ECG-frequency. Noise analysis at different frequencies reveals regional signal fluctuations in the frequency range between 2 and 10 Hz. Furthermore, initial results show that frequency changes in the order of <0.03 Hz corresponding to <1 nano Tesla can be detected. In addition to its potential use in neuroscientific studies, this new method opens a wide range of applications for fast physiological monitoring and can be easily combined with conventional high-resolution imaging.

Brain↗

Blood-oxygen-level-dependent MRI allows metabolic description of tissue at risk in acute stroke patients.

BACKGROUND AND PURPOSE: The delineation of the "penumbra" is of particular interest in acute stroke imaging. The "mismatch concept" applying perfusion-weighted imaging (PWI) and diffusion-weighted imaging (DWI) appears to be an oversimplification of the underlying electrophysiological tissue status. An additional parameter reflecting the metabolic state of the threatened brain tissue would improve our ability to describe the penumbra. One candidate is deoxyhemoglobin (deoxy-Hb) as an indicator of the oxygen extraction fraction that can be visualized by T2*-based blood oxygen level-dependent (BOLD) imaging. METHODS: We analyzed data from 32 patients with acute stroke in the territory of the middle cerebral artery. MRI included fluid-attenuated inversion recovery, DWI, PWI, time-of-flight angiography, and quantitative T2 and T2* (qT2, qT2*) imaging. Follow-up was performed on day 1 and days 5 to 8. We calculated 1/T2'=1/qT2*-1/qT2. Changes of T2', representing the deoxy-Hb effect, were analyzed by 3D regions of interest (ROIs): apparent diffusion coefficient lesion day 0 (L0), time-to-peak-lesion day 0 (T0), final infarct size days 5 to 8 (F5-8), lesion growth (LG; F5-8-L0), and surviving tissue (ST; T0-F5-8). RESULTS: We observed a clear decrease of T2' in the infarcted hemisphere compared with the unaffected control ROIs. The mean value showed the most pronounced loss of T2' signal intensity in L0 (-15.7%), followed by LG (-10.5%) and ST (-8.0%). CONCLUSIONS: The implementation of BOLD imaging in acute stroke MRI offers a noninvasive estimation of the O2 utilization and is able to add additional information concerning the present metabolic state of the threatened brain tissue. The changes in T2' intensity are visually noticeable in the reconstructed T2' images and provide a better estimation of the real penumbra.

Acute Disease↗

Advantages and limitations of prospective head motion compensation for MRI using an optical motion tracking device.

RATIONALE AND OBJECTIVES: Subject motion appears to be a limiting factor in numerous magnetic resonance (MR) imaging (MRI) applications. In particular, head tremor, which often accompanies stroke, may render certain high-resolution two- (2D) and three-dimensional (3D) techniques inapplicable. The reason for that is head movement during acquisition. The study objective is to achieve a method able to compensate for complete motion during data acquisition. The method should be usable for every sequence and easily implemented on different MR scanners. MATERIALS AND METHODS: The possibility of interfacing the MR scanner with an external optical motion-tracking system capable of determining the object's position with submillimeter accuracy and an update rate of 60 Hz is shown. Movement information on the object position (head) is used to compensate for motion in real time by updating the field of view (FOV) by recalculating the gradients and radiofrequency parameter of the MR scanner during acquisition of k-space data, based on tracking data. RESULTS: Results of rotation phantom, in vivo experiments, and implementation of three different MRI sequences, 2D spin echo, 3D gradient echo, and echo planar imaging, are presented. Finally, the proposed method is compared with the prospective motion correction software available on the scanner software. CONCLUSION: A prospective motion correction method that works in real time only by updating the FOV of the MR scanner is presented. Results show the feasibility of using an external optical motion-tracking system to compensate for strong and fast subject motion during acquisition.

Algorithms↗

Postoperative lymphoceles: detection with high-resolution MR lymphangiography.

Lymphoceles that do not resolve spontaneously or with treatment may be a major problem associated with a high degree of morbidity. Several imaging studies, including ultrasonography, computed tomography, magnetic resonance (MR) imaging, lymphography, lymphoscintigraphy, and intraoperative lymphatic mapping have been proposed to delineate lymphoceles before treatment. The present report describes the successful detection of three lymphoceles of the inguinal region with leaking lymphatic vessels by means of high-resolution MR lymphangiography.

Contrast Media↗

High-resolution MR lymphangiography in patients with primary and secondary lymphedema.

OBJECTIVE: The objective of our study was to evaluate the feasibility of high-resolution MR lymphangiography with intracutaneous injection of gadodiamide, a commercially available, nonionic, extracellular paramagnetic contrast agent, for the visualization of lymphatic vessels in patients with primary and secondary lymphedema. CONCLUSION: High-resolution MR lymphangiography is safe, is technically feasible, and has the potential to become a diagnostic imaging tool for patients with lymphedema.

Adult↗

Blood oxygen level-dependent MRI of cerebral CO2 reactivity in severe carotid stenosis and occlusion.

BACKGROUND AND PURPOSE: Impaired cerebrovascular reserve capacity (CVC) is a risk factor for ischemic events in patients with high-grade carotid stenosis and occlusion. In this study, the CVC in response to a CO2 challenge was evaluated with blood oxygen level-dependent (BOLD) MRI and the results compared with those of a transcranial Doppler CO2 tests. METHODS: A T2*-weighted single-shot multigradient echo-planar imaging sequence was used to determine cerebral CO2 reactivity. T2* values were calculated for each pixel at rest and during a challenge with 7% CO2, and a reference function was fitted to the T2* time courses. Whole-brain color-coded DeltaT2* parameter maps were calculated and visually evaluated for regional differences. Additionally, a region-of-interest analysis was undertaken. Average values for DeltaT2* normalized to changes in end-tidal PCO2 were calculated. RESULTS: Color parameter maps showed areas of decreased BOLD effect within the internal carotid artery territory in 12 of 13 hemispheres with impaired CVC in transcranial Doppler CO2 test. Regional normalized DeltaT2* was highly correlated with changes of middle cerebral artery blood flow velocity in transcranial Doppler CO2 test. Normalized DeltaT2* was significantly reduced in hemispheres with impaired CVC in transcranial Doppler (P<0.0001). CONCLUSIONS: BOLD MRI can easily be included in routine MRI exams. The technique is robust and yields diagnostic information concerning the cerebrovascular reserve.

Adult↗

Prospective head motion compensation for MRI by updating the gradients and radio frequency during data acquisition.

Subject motion appears to be a limiting factor in numerous magnetic resonance imaging (MRI) applications. For head imaging the subject's ability to maintain the same head position for a considerable period of time places restrictions on the total acquisition time. For healthy individuals this time typically does not exceed 10 minutes and may be considerably reduced in case of pathology. In particular, head tremor, which often accompanies stroke, may render certain high-resolution 2D and 3D techniques inapplicable. Several navigator techniques have been proposed to circumvent the subject motion problem. The most suitable for head imaging appears to be the orbital or spherical navigator methods. Navigators, however, not only lengthen the measurement because of the time required for acquisition of the position information, but also require additional excitation radio frequency (RF) pulses to be incorporated into the sequence timing, which disturbs the steady state. Here we demonstrate the possibility of interfacing the MR scanner with an external optical motion tracking system, capable of determining the object's position with sub-millimeter accuracy and an update rate of 60Hz. The movement information on the object position (head) is used to compensate the motion in real time. This is done by updating the field of view (FOV) by recalculating the gradients and the RF-parameter of the MRI tomograph during the acquisition of k-space data based on the tracking data. Results of rotation phantom, in vivo experiments and the implementation in two different MRI sequences are presented.

Artifacts↗

Additive effects of HIV and chronic methamphetamine use on brain metabolite abnormalities.

OBJECTIVE: Proton magnetic resonance spectroscopy (1H-MRS) showed decreased neuronal marker N-acetylaspartate and increased glial marker myo-inositol in subjects with chronic methamphetamine use and in subjects infected with HIV. The authors sought to determine whether HIV and a history of chronic methamphetamine use might have additive or interactive effects on brain metabolite abnormalities. METHOD: 1H-MRS was performed in 68 HIV-positive subjects (24 with a history of chronic methamphetamine use with a lifetime exposure of a mean of 2,167 g [SD=2,788] and last use a mean of 4.9 months earlier [SD=6.0]; 44 with no history of drug abuse) and 75 HIV-negative subjects (36 with a history of chronic methamphetamine use with a lifetime exposure of a mean of 8,241 g [SD=16,850] and last use a mean of 6.3 months earlier [SD=7.8]; 39 with no history of drug abuse). Concentrations of N-acetylaspartate, creatine, choline, and myo-inositol were measured in the frontal cortex, frontal white matter, and basal ganglia. RESULTS: HIV-negative subjects with a history of chronic methamphetamine use showed lower concentrations of the neuronal marker N-acetylaspartate in the frontal white matter and basal ganglia and higher concentrations of choline compounds and the glial marker myo-inositol in the frontal cortex, relative to subjects with no history of drug abuse. HIV-positive status was associated with lower concentrations of N-acetylaspartate and creatine in the frontal cortex and higher concentrations of myo-inositol in the white matter, compared with HIV-negative status. Compared to the mean concentrations of metabolites in HIV-negative subjects with no history of drug abuse, the mean concentrations in subjects with HIV and chronic methamphetamine use showed additive effects on N-acetylaspartate in all three regions (-9% in the basal ganglia, -7% in the frontal white matter, and -6% in the frontal gray matter), on creatine in the basal ganglia (-7%), and on myo-inositol in the frontal white matter (+11%). CONCLUSIONS: The combined effects of HIV and chronic methamphetamine use were consistent with an additive model, suggesting additional neuronal injury and glial activation due to the comorbid conditions.

Adult↗

Functional magnetic resonance imaging: a review of methodological aspects and clinical applications.

This paper gives an overview of the recent literature on methodological developments of functional magnetic resonance imaging (fMRI) and recent trends in clinical applications. With the recent introduction of high-field systems and methodological developments leading to more robust signal behavior, fMRI is in a transition state from a research modality for use by experts to a standard procedure with useful applications in patient management. Compared to the use in neuroscientific research, which is often based on BOLD techniques alone, the application in patients is distinguished by a multiparametric characterization of the brain using a combination of several techniques. Neuronal fiber tracking based on diffusion anisotropy measurements, in particular, has already turned out to provide relevant supplementary information to the BOLD-based cortical activation maps.

Brain↗

Persistent brain abnormalities in antiretroviral-naive HIV patients 3 months after HAART.

BACKGROUND: Proton magnetic resonance spectroscopy (1H-MRS) and neuropsychological tests may be useful for monitoring the effectiveness of highly active antiretroviral therapy (HAART) in HIV-associated brain injury. We aimed to evaluate whether brain abnormalities will improve 3 months after HAART. METHOD: Thirty-three HIV patients naive to antiretroviral medications were evaluated before and 3 months after HAART using 1H-MRS and neuropsychological tests; results were compared with those of 26 seronegative control subjects. RESULTS: Despite significant improvement in CD4 counts, and suppression of plasma and cerebrospinal fluid (CSF) viral loads, elevated brain metabolites (choline compounds and myoinositol in the frontal lobes) and neuropsychological tests abnormalities (including the computerized tests [CalCAP]) persisted after 3 months of HAART. In the basal ganglia, choline and myoinositol became elevated only after treatment. No interaction effect was observed between the number of CSF-penetrating drugs (one vs two) and changes (baseline vs 3 months) in any of the brain metabolites, cognitive performance or CSF viral load. CONCLUSIONS: The persistent brain abnormalities suggest ongoing repair or reactive inflammatory processes in the brain after 3 months of HAART. Regimens with two CSF-penetrating antiretroviral medications do not appear to be more effective than those with one CSF-penetrating drug in treating HIV brain injury at 3 months.

AIDS Dementia Complex↗

Perfusion MRI and computerized cognitive test abnormalities in abstinent methamphetamine users.

This study aims to determine possible persistent abnormalities in regional cerebral blood flow (relative rCBF) and cognitive function in abstinent methamphetamine (METH) users. Twenty METH-dependent subjects (abstinent for 8+/-2 months) and 20 age- and gender-matched controls were evaluated with perfusion magnetic resonance imaging (pMRI) and neuropsychological tests. METH users showed decreased relative rCBF bilaterally in putamen/insular cortices (right: -12%; left: -10%) and the right lateral parietal brain region (-11%), but increased relative rCBF bilaterally in the left temporoparietal white matter (+13%), the left occipital brain region: (+10%) and the right posterior parietal region (+24%). Interaction effects were observed between METH and gender in the right occipital cortex and a midline brain region; female METH users showed increased relative rCBF (+15% both regions) whereas the male METH users had decreased relative rCBF (-10% and -18%, respectively). METH users performed within normal ranges on standard neuropsychological tests; however, they were slower on several tasks on the California Computerized Assessment Package (CalCAP), especially tasks that required working memory. These findings suggest that METH abuse is associated with persistent physiologic changes in the brain, and these changes are accompanied by slower reaction times on computerized measures of cognitive function.

Adult↗

Optimization of signal behavior in the transition to driven equilibrium in steady-state free precession sequences.

A new technique to avoid the initial signal fluctuations in steady-state free precession (SSFP)-sequences, such as trueFISP, FIESTA, and refocused FFE, is presented. The "transition into driven equilibrium" (TIDE) sequence uses modified flip angles over the initialization phase of a SSFP experiment, which not only avoids image artifacts but also improves the signal-to-noise ratio (SNR) and contrast behavior compared to conventional approaches. TIDE is demonstrated to be robust against variations of T(1) and T(2), and leads to a monotonous signal evolution for off-resonance spins. The basic principles can also be applied repetitively to optimize continuous 3D acquisitions.

Head↗