Intraocular pressure and ocular pulse amplitude comparisons in different types of glaucoma using dynamic contour tonometry.

PURPOSE: To compare the intraocular pressures (IOP) and ocular pulse amplitudes (OPA) in patients with different types of glaucoma, ocular hypertension (OHT), and normal controls (NC) using dynamic contour tonometry (DCT) and the goldmann applanation tonometry (GAT). METHODS: 906 eyes of 501 adult patients in the following five groups were included in this cross-sectional study: primary open angle glaucoma (POAG), normal tension glaucoma (NTG), Pseudoexfoliative Glaucoma (PXG), OHT, and NC. The following tests were performed simultaneously during a single visit: IOP using DCT and GAT; OPA using DCT and central corneal thickness (CCT) using ultrasound pachymetry. Mixed effects regression models were used to compare the DCT and GAT IOP measurements in the five groups; the effect of CCT on IOP and the relationship between OPA and IOP within each group. RESULTS: DCT consistently had higher IOP values than GAT in POAG, PXG, NTG, and controls (p < 0.001) but not in OHT (p = 0.84). DCT IOP did not change while GAT IOP showed a non-significant increase (p = 0.09) with increased corneal thickness in each group. OPA was found to be highest in OHT (3.61 mmHg) and lowest in the control group (2.86 mmHg) and significantly increased with IOP in all groups. CONCLUSIONS: DCT measures an IOP that is significantly higher than GAT IOP in glaucoma and control subjects but not in ocular hypertensives. Furthermore, the DCT may measure an IOP that is independent of the CCT, which may not be true for the GAT, which increases with the CCT. OPA was highest in OHT and may be affected by the IOP.

Blood Pressure↗

Rheumatoid arthritis is a risk factor for dry eye in the Indian population.

PURPOSE: To compare the prevalence and severity of dry eye in patients with rheumatoid arthritis (RA) with that in age- and sex-matched controls in the Indian population. METHODS: A cross-sectional study was performed on 84 randomly selected eyes of 84 adult patients with well-documented rheumatoid arthritis and 84 eyes of 84 age- and sex-matched controls in the Department of Ophthalmology, Seth G.S. Medical College and K.E.M. Hospital. McMonnie's dry eye questionnaire was used to classify the patients on the basis of their symptoms. Dry eye was diagnosed if the wetting on Schirmer filter paper test was < or =5 mm at 5 minutes and the tear film breakup time was < 10 seconds on slit-lamp examination after fluorescein staining. RESULTS: Twenty three patients (27.3%) with rheumatoid arthritis had dry eyes based on the Schirmer test as compared to 10 (12%) age- and sex-matched controls; 19 (22.62%) patients with RA had a tear film breakup time of < 10 sec. on slit-lamp examination, compared to 8 (9.52%) patients without RA. The difference in the mean wetting (p = 0.003) and mean tear film breakup time (p < 0.001) between RA and non-RA patients was statistically significant. Ocular symptoms had a limited correlation with the results of these tests. CONCLUSIONS: Patients with RA in the Indian population have a significantly higher prevalence and severity of dry eye when compared to age- and sex-matched controls.

Adult↗

Dynamic contour tonometry: principle and use.

Interindividual variability of central corneal thickness has been found to be a source of error for conventional Goldmann applanation tonometry. The dynamic contour tonometer represents a potentially new technology for non-invasive and direct intraocular pressure (IOP) measurement, and has been proposed to accurately measure the true IOP irrespective of the corneal thickness. It is based on the principle that when the tip of the device exactly matches the contour of the cornea, the pressure measured by a transducer placed on its tip is an accurate indicator of the true IOP. This device is also capable of measuring the ocular pulse amplitude, a variable that has controversial significance in the diagnosis and management of glaucoma. Even though this technique seems to be very promising, further studies are required to conclusively determine the effectiveness of the dynamic contour tonometer in patients having an abnormal or irregular corneal contour.

Equipment Design↗