Orhun K Muratoglu

Publications and source records attributed to Orhun K Muratoglu.

At least 19 recordsLinked to original sources

Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive film.

Stress magnitude and distribution of both conventional polyethylene versus a crosslinked polyethylene in the liner of a total hip replacement (THR) were examined using finite element analysis and pressure sensitive film. Both types of polyethylene were assessed against head sizes of 22 and 28 mm with 5-mm thick polyethylene liners and head sizes of 28, 38, and 46 mm with 3-mm thick polyethylene liners. Liners with 5-mm conventional polyethylene represented successful combinations with long track records. Our hypothesis was that although the combination of the large head and the lower modulus of the highly crosslinked polyethylene would lead to lower stresses, the stresses would be excessive if the liner was extremely thin at 3 mm. Von Mises stresses at the articulating surface of the highly crosslinked liners were lower, when compared to conventional polyethylene, in every THR size examined. Specifically, however, the 38- and 46-mm inner diameter (ID) highly crosslinked polyethylene even at the extreme of only 3-mm thick had lower stresses than the 22-mm ID conventional liner of 5-mm thickness. These data indicate that the use of a large head against highly crosslinked material even at 3-mm thickness results in lower stresses than in an existing conventional 22-mm head and 5-mm thick combination. Obviously, other considerations will influence the minimum thickness to be recommended.

Acetabulum↗

Effects of solvent dehydration on creep resistance of poly(vinyl alcohol) hydrogel.

As a synthetic replacement material for osteochondral defect repair, poly(vinyl alcohol) (PVA) hydrogels offer a great potential due to their high water content and strong mechanical integrity. To survive the high stress environment in the joint space, high creep resistance becomes one of the key requirements for hydrogel implants. We hypothesized that reducing the equilibrium water content (EWC) of hydrogels would improve their creep resistance. We investigated the effect of dehydration of PVA theta-gels in various solvent/solution media followed by rehydration in saline solution. Decreasing EWC increased the creep resistance of PVA theta-gels. The most effective medium was isopropyl alcohol for reducing the EWC and increasing the creep resistance of PVA theta-gels.

2-Propanol↗

The effect of alpha-tocopherol on the oxidation and free radical decay in irradiated UHMWPE.

We developed a radiation cross-linked ultra-high molecular weight polyethylene (UHMWPE) stabilized with alpha-tocopherol (Vitamin E) as a bearing material in total joint replacements. The stabilizing effect of alpha-tocopherol on free radical reactions in UHMWPE is not well understood. We investigated the effect of alpha-tocopherol on the oxidation and transformation of residual free radicals during real-time aging of alpha-tocopherol-doped, irradiated UHMWPE (alphaTPE) and irradiated UHMWPE (control). Samples were aged at 22 degrees C (room temperature) in air, at 40 degrees C in air and at 40 degrees C in water for 7 months. During the first month, alphaTPE showed some oxidation at the surface, which stayed constant thereafter. Control exhibited substantial oxidation in the subsurface region, which increased with time. The alkyl/allyl free radicals transformed to oxygen centered ones in both materials; this transformation occurred faster in alpha-TPE. In summary, the real-time oxidation behavior of alpha-TPE was consistent with that observed using accelerated aging methods. This new UHMWPE is oxidation resistant and is expected to maintain its properties in the long term.

Electron Spin Resonance Spectroscopy↗

Comparison of conventional and highly crosslinked UHMWPE patellae evaluated by a new in vitro patellofemoral joint simulator.

A series of in vitro patella damage tests were developed using a knee simulator to investigate electron-beam-irradiated and -melted ultra-high molecular weight polyethylene and conventional ultra-high molecular weight polyethylene at the patellofemoral articulation. Three different simulations were created: (i) normal gait with optimal component alignment, (ii) stair climbing with optimal component alignment, and (iii) stair climbing with 4 degrees of femoral component internal rotation to simulate a component malalignment condition. In the last two simulations, all patellae were artificially aged. In normal gait, the unaged conventional and highly crosslinked patellae demonstrated similar behavior. In both stair climbing tests, unlike the aged highly crosslinked components, the aged conventional patellae developed cracks by 2 million cycles. These results demonstrate the potential advantage of highly crosslinked polyethylene for the patella.

Biocompatible Materials↗

Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E.

Our hypothesis was that cross-linked, ultrahigh-molecular weight polyethylene (UHMWPE) stabilized with vitamin E (alpha-tocopherol) would be wear-resistant and fatigue-resistant. Acetabular liners were radiation cross-linked, doped with vitamin E, and gamma-sterilized. Hip simulator wear rate of vitamin E-stabilized UHMWPE was approximately 1 and 6 mg/million-cycles in clean serum and in serum with third-body particles, respectively, a 4-fold to 10-fold decrease from that of conventional UHMWPE. The ultimate strength, yield strength, elongation at break, and fatigue resistance of vitamin E-stabilized UHMWPE were significantly higher than that of 100 kGy-irradiated and melted UHMWPE, and were unaffected by accelerated aging. Rim impingement testing with 3.7-mm-thick acetabular liners up to 2 million-cycles showed no significant damage of the cross-linked liners compared with conventional, gamma-sterilized in inert UHMWPE, vitamin E-stabilized liners. The data indicate good in vitro wear properties and improved mechanical and fatigue properties for vitamin E-stabilized, cross-linked UHMWPE.

Fatigue↗

In vitro comparison of frictional torque and torsional resistance of aged conventional gamma-in-nitrogen sterilized polyethylene versus aged highly crosslinked polyethylene articulating against head sizes larger than 32 mm.

BACKGROUND: The advent of highly crosslinked polyethylene has allowed the re-evaluation of the use of femoral heads larger than 32 mm for metal-on-polyethylene total hip arthroplasties. However, the effect of larger heads on the frictional torque of highly crosslinked polyethylene is unknown. METHODS: We performed an in vitro examination of the effect of larger chrome cobalt femoral heads (40 mm diameter) on the frictional torque and torsional resistance of hip articulations on aged liners of polyethylene that were sterilized by gamma rays while in nitrogen, and aged highly crosslinked polyethylene. The frictional torque at the femoral head articulation was usually higher for the highly crosslinked polyethylene than for the conventional polyethylene. The aged conventional liners oxidized considerably, which led to gross failure of the polyethylene at the anti-rotation portion of the rim. The aged crosslinked polyethylene showed no such failures despite the higher frictional torque. INTERPRETATION: Our findings suggest that in terms of torsional resistance to fatigue when studied as a device, rather than as an isolated material, under these conditions, aged highly crosslinked polyethylene is preferable to aged conventional polyethylene.

Arthroplasty, Replacement, Hip↗

Mechanisms of decrease in fatigue crack propagation resistance in irradiated and melted UHMWPE.

Adhesive/abrasive wear in ultra-high molecular weight polyethylene (UHMWPE) has been minimized by radiation cross-linking. Irradiation is typically followed by melting to eliminate residual free radicals that cause oxidative embrittlement. Irradiation and subsequent melting reduce the strength and fatigue resistance of the polymer. We determined the radiation dose dependence and decoupled the effects of post-irradiation melting on the crystallinity, mechanical properties and fatigue crack propagation resistance of room temperature irradiated UHMWPE from those of irradiation alone. Stiffness and yield strength, were largely not affected by increasing radiation dose but were affected by changes in crystallinity, whereas plastic properties, ultimate tensile strength and elongation at break, were dominated at different radiation dose ranges by changes in radiation dose or crystallinity. Fatigue crack propagation resistance was shown to decrease with increase in radiation dose and with decrease in crystalline content. Morphology of fracture surfaces revealed loss of ductility with increase in radiation dose and more detrimental effects on ductility at lower radiation doses after post-irradiation melting.

Cold Temperature↗

The measurement of creep in ultrahigh molecular weight polyethylene: a comparison of conventional versus highly cross-linked polyethylene.

Quantification of creep of highly cross-linked polyethylene would enable separation of creep from wear when evaluating femoral head penetration into polyethylene. We compared creep magnitude of a highly cross-linked versus conventional polyethylene in the laboratory. Twelve acetabular liners of each material were tested, 6 of which had a 32-mm inner diameter (ID) and 6 had 28-mm ID. Creep was measured using coordinate measuring machines during loading at 2 Hz without motion to 4 million cycles. Penetration into 32-mm ID conventional liners reached 97 microm versus 107 microm for highly cross-linked material, not significant. Penetration into 28-mm conventional liners was 132 microm versus 155 microm for highly cross-linked material (P = .017). Ninety percent of the creep had occurred by 2.5 million cycles.

Arthroplasty, Replacement, Hip↗

Third-body wear testing of a highly cross-linked acetabular liner: the effect of large femoral head size in the presence of particulate poly(methyl-methacrylate) debris.

The hip simulator wear performance of an electron beam cross-linked and subsequently melted ultrahigh molecular weight polyethylene against femoral heads of 28-, 38-, and 46-mm diameter in the presence of poly(methyl-methacrylate) particulate debris was contrasted with that of conventional polyethylene against a 46-mm diameter head. Over 5 million cycles of testing, the average wear rate of the conventional polyethylene liners was 29.3 +/- 3.0 mg per million cycles. All highly cross-linked components exhibited marked reduction in wear, with the highest wear measuring 0.74 +/- 0.85 mg per million cycles. This study, using a clinically relevant third-body material, showed the electron beam cross-linked material to be far more resistant to this third-body wear than conventional ultrahigh molecular weight polyethylene, even when very large diameter femoral heads were used.

Acetabulum↗

Characterization of irradiated blends of alpha-tocopherol and UHMWPE.

Adhesive/abrasive wear in ultra-high molecular weight polyethylene (UHMWPE) has been minimized by radiation cross-linking. Irradiation is followed by melting to eliminate residual free radicals and avoid long-term oxidative embrittlement. However, post-irradiation melting reduces the crystallinity of the polymer and hence its strength and fatigue resistance. We proposed an alternative to post-irradiation melting to be the incorporation of the antioxidant alpha-tocopherol into UHMWPE prior to consolidation. alpha-Tocopherol is known to react with oxygen and oxidized lipids, stabilizing them against further oxidative degradation reactions. We blended GUR 1050 UHMWPE resin powder with alpha-tocopherol at 0.1 and 0.3 wt% and consolidated these blends. Then we gamma-irradiated these blends to 100-kGy. We characterized the effect of alpha-tocopherol on the cross-linking efficiency, oxidative stability, wear behavior and mechanical properties of the blends. (I) The cross-link density of virgin, 0.1 and 0.3 wt% alpha-tocopherol blended, 100-kGy irradiated UHMWPEs were 175+/-19, 146+/-4 and 93+/-4 mol/m3, respectively. (II) Maximum oxidation indices for 100-kGy irradiated UHMWPE previously blended with 0, 0.1 and 0.3 wt% alpha-tocopherol that were subjected to accelerated aging at 80 degrees C in air for 5 weeks were 3.32, 0.09, and 0.05, respectively. (III) The pin-on-disc wear rates of 100-kGy irradiated UHMWPE previously blended with 0.1 and 0.3 wt% alpha-tocopherol that were subjected to accelerated aging at 80 degrees C in air for 5 weeks were 2.10+/-0.17 and 5.01+/-0.76 mg/million cycles, respectively. (IV) Both accelerated aged, alpha-tocopherol-blended 100-kGy irradiated UHMWPEs showed higher ultimate tensile strength, higher yield strength, and lower elastic modulus when compared to 100-kGy irradiated, virgin UHMWPE. These results showed that alpha-tocopherol-blended 100-kGy irradiated UHMWPEs were not cross-linked to the same extent as the 100-kGy irradiated, virgin UHMWPE.

Aging↗

A review of current cross-linked polyethylenes used in total joint arthroplasty.

Major improvements have been made in new polyethylenes in regards to wear resistance and oxidation resistance. The background for and explanation of these improvements are presented in this study. The various manufacturing processes are described along with the possible features that the differences in manufacturing processes may have on wear, rate of particle generation, oxidation and mechanical properties. The role of some of the new polyethylenes in permitting the use of larger-diameter heads and the advantages of large-head diameters are discussed. Some of the advantages of metal-on-polyethylene versus hard-on-hard bearings also are described.

Arthroplasty, Replacement↗

Ex vivo wear of conventional and cross-linked polyethylene acetabular liners.

Explanted highly cross-linked polyethylene acetabular liners show third-body scratching. It was suggested that this surface damage could increase the wear rate of highly cross-linked polyethylene. We investigated the wear behavior of surgically explanted highly cross-linked and conventional acetabular liners using a hip simulator. Highly cross-linked explants showed no weight loss. The scratches and original machine marks of the highly cross-linked liners present at explantation remained during testing; the wear rates of these liners were 1.1 +/- 2.3 mg/million cycles, representing weight gain. In contrast, conventional liners showed wear rates of -12.9 +/- 1.4 mg/million cycles, representing weight loss. Wear was associated with rapid surface polishing and scratch elimination. After testing, the liners were melted to trigger shape memory and recover plastic deformation-induced surface changes. Highly cross-linked liners showed substantial recovery of original machining marks after melting, indicating that the scratches were a result of plastic deformation and not wear. None of the conventional polyethylenes showed any recovery after melting. The wear resistance of the highly cross-linked polyethylene studied was not compromised by surface changes that occurred during the first year of in vivo service.

Acetabulum↗

Surface analysis of early retrieved acetabular polyethylene liners: a comparison of conventional and highly crosslinked polyethylenes.

In vivo wear behavior of 16 highly cross-linked and 19 conventional polyethylene acetabular explants, at an average in vivo duration of 6 months were studied. Highly cross-linked groups showed machining marks from the original manufacturing process in some areas and extensive scratching and some polishing of the articulating surfaces. The conventional group showed greater loss of machining marks, scratching, and polishing. Representative samples were melted to allow recovery of plastic deformation and to show true removal of material caused by wear. Melt-recovery experiments consistently showed the disappearance of surface scratches and the restoration of the original machining marks in the highly cross-linked explants. In the conventional group, few of the scratches were eliminated and only limited restoration of the machining marks was apparent. These observations support the hypothesis that the early in vivo scratching of highly cross-linked polyethylene acetabular liners is primarily caused by plastic deformation.

Cross-Linking Reagents↗

Knee-simulator testing of conventional and cross-linked polyethylene tibial inserts.

We compared the resistance to delamination and to adhesive/abrasive wear of conventional and highly cross-linked polyethylene tibial inserts of a cruciate-retaining total knee design using a knee simulator. Both groups were tested after aggressive, accelerated aging, and 1 set of conventional inserts was studied without aging. Aging oxidized the conventional, but not the highly cross-linked, inserts. The simulated normal gait testing lasted for 5 and 10 million cycles for the conventional and highly cross-linked inserts, respectively. Aged conventional inserts showed delaminations, whereas none were observed in the unaged conventional and aged cross-linked inserts. Wear rates measured by the gravimetric method were 9 +/- 2 mm3, 10 +/- 4 mm3, and 1 +/- 0 mm3 per million cycles; by the metrologic method, they were 8 +/- 1 mm3, 9 +/- 2 mm3, and 3 +/- 0 mm3 for the unaged conventional, aged conventional, and aged highly crosslinked inserts, respectively. In the test model used, oxidation led to delamination, whereas increased cross-link density resulted in reduced adhesive/abrasive wear of tibial inserts.

Equipment Failure Analysis↗

Effect of lipid absorption on wear and compressive properties of unirradiated and highly crosslinked UHMWPE: an in vitro experimental model.

Ultra-high molecular weight polyethylene (UHMWPE or polyethylene) components used in total joint arthroplasty absorb lipids in vivo. However, the effect, if any, of this lipid uptake on both the wear and the mechanical properties of polyethylene is not known. We contrasted the effects of lipid diffusion into the polyethylene on the wear and mechanical properties of unirradiated UHMWPE versus that into highly crosslinked UHMWPE preparation (a 95-kGy irradiated and melted UHMWPE). We doped test samples of both types of polyethylenes with either squalene alone or a 15% (w/v) solution of cholestene/squalene (CH/SQ) solution. The diffusion profiles were quantified using infrared microscopy as a function of depth away from free surfaces; we used the 1620 and 1680 cm(-1) absorbances characteristic of CH and SQ, respectively. There were no statistically significant changes in the bi-directional pin-on-disk wear rates of neither type of polyethylene after lipid absorption. On the other hand, compressive modulus and compressive strength of both polyethylenes decreased after doping with either lipid.

Absorption↗

Knee simulator wear of polyethylene tibias articulating against explanted rough femoral components.

Highly cross-linked and melted polyethylene tibial inserts have recently been introduced for clinical use to reduce fatigue damage and adhesive wear in tibial inserts. Other authors have studied the effect of counterface roughness on the wear behavior of polyethylene tibial inserts in knee simulators using femoral components that were roughened artificially. They reported a higher wear rate with highly cross-linked polyethylene than with unirradiated polyethylene tibial inserts. Artificial roughening of femoral components may not be clinically relevant. To evaluate this concern, we studied the wear behavior of highly cross-linked and conventional polyethylene tibial inserts articulating in vitro against surgically retrieved femoral components that had become roughened in vivo. The wear rate of the highly cross-linked polyethylene (5.9 and 6.8 mg/1 million cycles with 100 and 50% serum) was 80% lower than the wear rate of the conventional polyethylene (33.5 and 32.2 mg/1 million cycles with 100 and 50% serum) tibial inserts after 2 million cycles of simulated gait. This study suggests that during in vivo use, scratches that are generated on the femoral components are likely to produce a higher wear rate with both cross-linked and conventional polyethylene than a smooth femoral component, but that this wear rate is likely to be higher with conventional polyethylene than with highly cross-linked polyethylene tibial inserts.

Femur↗

The use of trans-vinylene formation in quantifying the spatial distribution of electron beam penetration in polyethylene. Single-sided, double-sided and shielded irradiation.

The use of the quantification of trans-vinylene unsaturations in irradiated ultrahigh molecular weight polyethylene (UHMWPE) in determining the spatial distribution of electron beam penetration was investigated. UHMWPE was irradiated with a 10MeV linear electron beam accelerator to 100kGy at both room temperature and 125 degrees C in air. The irradiation was carried out in shielded and unshielded single-sided and unshielded double-sided irradiation modes. Dose-depth profiles were measured by quantifying the yields of trans-vinylene unsaturations as a function of depth away from the e-beam incidence surfaces using infrared spectroscopy. The extent of beam penetration increased with increasing irradiation temperature as was manifested by the increase in the iso-dose penetration with the unshielded single-sided irradiation and increased dose overlap with the unshielded double-sided irradiation. The optimum thickness with maximum uniformity in dose-depth distribution for double-sided irradiation was 85 and 90mm for 25 degrees C and 125 degrees C irradiation temperatures, respectively.

Biocompatible Materials↗

Effect of consolidation on adhesive and abrasive wear of ultra high molecular weight polyethylene.

Total hip replacement (THR) is widely performed to recover hip joint functions lost by trauma or disease and to relieve pain. The major cause of failure in THR is the wear of the ultra high molecular weight polyethylene (UHMWPE) component. The dominant wear mechanism in THR occurs through adhesion and abrasion. While poor consolidation of UHMWPE is known to increase the incidence of a different damage mode, delamination, which is the dominant wear mechanism in tibial inserts but uncommon in THR, the effect of consolidation on adhesive and abrasive wear of UHMWPE is not clear. In this study UHMWPE resin was subjected to hot isostatic pressing under a pressure of 138MPa at different temperatures (210 degrees C, 250 degrees C, and 300 degrees C) to achieve varying degrees of consolidation. The extent of consolidation was determined by optical microscopy using thin sections, and by scanning electron microscopy using cryofractured and solvent etched specimens. Wear behavior of the samples with varying degree of consolidation was determined using a bi-directional pin-on-disc machine simulating conditions in a hip joint. Increasing the processing temperature decreased the incidence of fusion defects and particle boundaries reflecting the powder flakes of the virgin resin, improving the consolidation. However, the bi-directional pin-on-disc wear rate did not change with the processing temperature, indicating that adhesive and abrasive wear is independent of the extent of consolidation in the range of parameters studied here.

Biocompatible Materials↗