PubMed Health⌕ Search

Biomedical subjects

Osamu Tagusari

Publications and source records attributed to Osamu Tagusari.

At least 37 records · Page 2Linked to original sources

Mitral valve repair and cryo-Maze procedure in Ehlers-Danlos syndrome.

A 48-year-old man presented with typical features of Ehlers-Danlos syndrome, such as soft and hyperextensible skin, subcutaneous nodules, clubbed feet, and a mild degree of pigeon chest. In addition, his past history revealed congenital dislocation of the hip joint, retinal detachment, and repeated episodes of congestive heart failure due to severe mitral regurgitation and atrial fibrillation. We subjected the patient to surgical repair of the mitral valve combined with the maze procedure, which proved successful.

Atrial Fibrillation↗

Successful excision of a cystic tumor of the atrioventricular nodal region.

Cystic tumor of the atrioventricular nodal region is a rare cardiac primary tumor that can cause heart blockage and sudden death. Antemortem diagnosis and successful excision of the atrioventricular nodal region are extremely rare. A 45-year-old woman who presented with palpitations is reported. Electrocardiography revealed first-degree atrioventricular block. Echocardiography, computed tomography, and magnetic resonance imaging scans revealed a cystic mass attached to the interatrial septum. Complete surgical excision of the mass was achieved, although placement of a permanent pacemaker was required for complete heart blockage. Histopathological examination revealed the mass to be a cystic tumor of the atrioventricular nodal region. A 5-year follow-up has revealed no sign of recurrence.

Atrioventricular Node↗

Infective tricuspid valve endocarditis with pulmonary emboli caused by Campylobacter fetus after tooth extraction.

We describe a case of infective endocarditis caused by Campylobacter fetus accompanied by pulmonary emboli. A 52-year-old man was referred to our hospital due to febrile temperatures with a history of dental treatment followed by eating raw meat. Computed tomography revealed multiple infiltrations and a nodule with low attenuation area and feeding vessels. A mobile mass, possible vegetation, attached to the tricuspid valve was detected by transthoracic echocardiography. Two blood cultures disclosed Campylobacter fetus. Long-term antibiotic therapy was given, curing the infection with valvuloplasty. We presented the possibility that infective Campylobacter fetus endocarditis after dental treatment was caused by eating raw meat.

Campylobacter Infections↗

Accelerated graft disease in a composite saphenous vein with internal thoracic artery in a chronic renal dialysis patient.

A 59-year-old man with 18-year history of renal dialysis due to chronic nephritis suffered coronary artery disease, which was complete occlusion of the right coronary artery and diffuse 90% stenosis of the proximal left anterior descending artery. Off-pump coronary artery bypass grafting was performed. Saphenous vein (SV) was anastomosed with left internal thoracic artery (ITA) as a T-graft. Left ITA was anastomosed to the left anterior descending artery. The end of SV was sewn on the posterior descending artery. Coronary and graft angiography performed 2 weeks after the operation showed good patency with good distal run-off of both left ITA and SV. Three months after the operation, he was admitted with unstable angina. Angiography revealed accelerated SV graft stenosis without any change of prior coronary disease. However, angiography 7 months after the operation revealed complete obstruction of the SV graft when he was admitted because of recurrent anginal pain.

Angina Pectoris↗

Rationale of off-pump coronary artery bypass grafting for left main trunk disease.

OBJECTIVE: Off-pump coronary artery bypass grafting (OPCAB) remains controversial in patients with left main trunk (LMT) disease because of a concern about the ability to tolerate hemodynamic instability. This study examined the safety of OPCAB for LMT disease compared with conventional coronary artery bypass grafting (CABG). METHODS: Between April 1997 and December 2002, 257 consecutive patients with LMT stenosis who underwent CABG were enrolled. There were 98 patients who received CABG with the aid of cardiopulmonary bypass (CCAB group), and 159 patients who received OPCAB (OPCAB group). RESULTS: There was no patient who converted to on-pump intraoperatively due to hemodynamic instability. Both intraoperative blood loss and blood transfusion incidence were lower in the OPCAB group. Postoperative course was similar, however, pulmonary complications were less observed postoperatively in the OPCAB group. No hypoperfusion syndrome was seen postoperatively in both groups. The average number of anastomosis was 3.2+/-1.1 in the CCAB group and 3.2+/-1.0 in the OPCAB group (p=0.645). Total arterial OPCAB with an aorta no-touch technique was achieved in 142 patients (89.3%) in OPCAB group. Postoperative angiography was performed in 95 patients in CCAB (96.9%), and in 141 patients in OPCAB (89.8%). Although graft patency of arterial grafts was good in both groups (100% in CCAB and 98.3% in OPCAB), saphenous vein graft patency was slightly lower in both groups (93.4% in CCAB and 76.5% in OPCAB) compared with arterial grafts. CONCLUSION: OPCAB allows a safe and effective treatment of LMT disease.

Aged↗

Comparison of off-pump and on-pump coronary artery bypass grafting in midterm results.

OBJECTIVE: Off-pump coronary artery bypass grafting (OPCAB) has become a procedure of choice for surgical treatment of coronary artery disease. Although early advantages of OPCAB were confirmed in comparison with conventional on-pump coronary artery bypass grafting (CABG), late cardiac complications are still controversial. We examined midterm results of OPCAB compared with standard CABG. METHODS: Between July 1997 and April 2002, 736 consecutive patients who underwent isolated CABG were retrospectively reviewed. The OPCAB group (Group I) comprised 357 patients (49%), and the on-pump CABG group (Group II) 379 patients (51%). Their preoperative, intraoperative, and follow-up data were analyzed. RESULTS: The mean number of distal anastomoses and the early graft patency were not greatly different between the two groups. The actuarial survival rate at 3 years was not significantly different between Group I (98.3%) and Group II (98.2%) (p = 0.71). The frequency of cardiac events was 4.2%/patient-year in Group I and 2.6%/patient-year in Group II (p = 0.12). The actuarial event free rates were not different between the two groups (p = 0.61). The cardiac event free rates at 3 years were significantly (p = 0.011) higher in patients with complete revascularization (96.7%) than without complete revascularization in Group I (69.2%) and in Group II (92.7% versus 85.9%, p = 0.026). CONCLUSIONS: Midterm clinical outcome in OPCAB is as good as conventional on-pump CABG. Incomplete revascularization caused cardiac events more frequently than complete revascularization both in OPCAB and on-pump CABG in the intermediate follow-up.

Cardiopulmonary Bypass↗

Rationale for off-pump coronary revascularization to small branches--angiographic study of 1,283 anastomoses in 408 patients.

BACKGROUND: Off-pump coronary artery bypass grafting (OPCAB) has gained wide acceptance in tandem with the development of the stabilizer and associated operative techniques. However bypass grafting to the small branches of a beating heart is technically demanding and remains controversial. In the present study we evaluated the graft patency and quality of anastomoses to small coronary arteries by early postoperative angiography. METHODS: Between March 2000 and December 2002 a total of 1,328 anastomosed sites to coronary branches were studied angiographically in 404 patients representing 88.6% of all cases who underwent OPCAB in this period. The coronary artery branches were categorized as large (>1.5 mm, group L: 1,028 anastomoses sites) or small (< 1.5 mm, group S: 300 sites) by intraoperative measurement. As in situ grafts the internal thoracic artery (ITA) and the gastroepiploic artery (GEA) were used at 504 and 28 distal anastomosis sites respectively. The radial artery (RA) was used as a composite graft for 739 distal anastomosis sites. Sequential bypass grafting was performed at 388 anastomosis sites in side-to-side fashion. Arterial grafts were used in 96.1% of total bypass grafting. RESULTS: The percentage of male gender was 78.3% in group S and 87.2% in group L (p = 0.025). The ITA was used in 43.7% of group L and 18.3% of group S (p < 0.0001). The RA was used in 49.4% of group L and 77% of group S (p < 0.0001). The overall patency and stenosis free rates (FitzGibbon Type A) were 97.2% and 96.2%. Graft patency and stenosis free rates in group S (96.7% and 93.3%) were as good as those in group L (97.5% and 97.1%). In group S, the patency and stenosis free rates of SV grafts were 71.4% and 57.1%. On the other hand, those of ITA grafts were 100% and 98.3% (p = 0.53 vs. saphenous vein graft [SVG]) and RA grafts were 95.8% and 92.1% (p = 0.61 vs. SVG) respectively. In group S, the graft patency and stenosis free rates of bypass to the obtuse marginal (OM) (93.7% and 87.5%) were slightly lower than those to other implantation sites left anterior descending (LAD: 100% and 97.3%; PL: 96.5% and 92.3%; DI: 98.0% and 96%; PDA: 97.0% and 97.0%; right coronary artery [RCA]: 100% and 100%) although there was no statistical significance. The graft patency and stenosis free rates were slightly better with side-to-side anastomosis than with end-to-side anastomosis (side-to-side: 98.1% and 95.8% vs. end-to-side 96.3% and 86.3%) in group S. CONCLUSIONS: OPCAB to small coronary artery branches with arterial grafts provided satisfactory graft patency and stenosis free rates.

Anastomosis, Surgical↗

Competitive flow in arterial composite grafts and effect of graft arrangement in Off-Pump coronary revascularization.

BACKGROUND: We sought to investigate the incidence of competitive flow in arterial composite grafts and to delineate the effect of the location of moderately stenotic branch, the extent of the revascularized territories and the arrangement of in situ and free arterial grafts in off-pump coronary artery bypass grafting (OPCAB). METHODS: Three hundred eighteen patients who underwent OPCAB with aorta no-touch technique using the composite graft with totally arterial materials between December 2000 and March 2003 were studied. A total of 362 composite grafts were used. We reviewed their coronary angiography before and early after operation. Competitive flow was defined as the phenomenon that at least one of the distal anastomotic sites of the composite graft was not opacified in in situ graft angiography, but clearly opacified in native coronary angiography. The number of distal anastomoses was 3.47 +/- 0.93 per patient and 2.87 +/- 0.81 per composite graft. RESULTS: Early patency rate of the distal anastomotic sites of composite grafts was 98.7%. Competitive flow was found in 53/362 (14.6%) composite grafts, and graft occlusion occurred in 13/362 (3.6%) composite grafts. In the multivariate analysis of 362 composite grafts, 75% stenosis in right coronary artery (RCA) territory (p < 0.0001) and the number of distal anastomoses (p = 0.004) were significant predictors of competitive flow and graft occlusion. Multivariate analysis of 318 patients demonstrated that 75% stenosis in RCA territory (p < 0.0001) and the total number of distal anastomoses (p = 0.003) were statistically significant predictors of competitive flow and graft occlusion. The use of more than two in situ grafts and the shape of composite graft (branched or straight) did not have significant correlation with the outcome. CONCLUSIONS: Coronary artery revascularization using composite arterial grafts provided satisfactory early patency rates with an acceptable incidence of competitive flow. Because the implication of competitive flow in an arterial composite graft may differ from that in conventional bypass grafts unpredictably, long-term follow-up is mandatory.

Aged↗

Total arterial off-pump coronary artery bypass grafting for revascularization of the total coronary system: clinical outcome and angiographic evaluation.

BACKGROUND: We assessed the clinical outcome and conducted an angiographic study of total arterial off-pump coronary artery bypass grafting for revascularization of the total coronary system. METHODS: Of 382 consecutive patients who underwent off-pump coronary artery bypass between April 2000 and December 2002, 235 patients (193 men and 42 women, mean age 66 +/- 9 years) with three-vessel disease underwent off-pump coronary artery bypass with all arterial grafts. A total of 872 vessels were bypassed (average number of grafts 3.7 +/- 0.8). The internal thoracic arteries, radial arteries, and gastroepiploic arteries were used for revascularization of 306, 542, and 24 coronary arteries, respectively. Two hundred twenty-five patients underwent revascularization with composite grafts that were connected to the in situ internal thoracic artery (Y configuration 181, I configuration 55, K configuration 27, X configuration 3, T configuration 1); 10 patients underwent revascularization with all in situ grafts. RESULTS: Three (1.3%) hospital deaths and 1 late death occurred. There were no occurrences of clinical underperfusion syndrome or new intraaortic balloon pump insertion. Cerebral infarction occurred in 2 patients (0.8%). Early postoperative angiography was performed on 833 grafts in 223 patients (95%); the overall patency rate was 98%. Stratified by coronary distribution, the patency rate was 99% (218/221) in the left anterior descending artery, 97% (84/87) in the diagonal artery, 99% (70/71) in the obtuse marginal artery, 98% (262/268) in the posterolateral artery, 98% (167/170) in the posterior descending artery, and 100% (16/16) in the right coronary artery. CONCLUSIONS: Total arterial off-pump coronary artery bypass yielded good clinical results and an excellent patency rate of revascularization for the total coronary system.

Adult↗

Consequence of atrial fibrillation and the risk of embolism after percutaneous mitral commissurotomy: the necessity of the maze procedure.

BACKGROUND: We sought to investigate the incidence and risk of embolism after percutaneous balloon mitral commissurotomy (PMC) and delineated the necessity of the maze procedure in patients with atrial fibrillation (AF). METHODS: Clinical records of 326 patients, who underwent PMC between April 1988 and March 2003, and 162 patients, who underwent mitral valve surgery (MVS) combined with the maze procedure (MVS/maze) in the same period, were reviewed. We examined the consequence of cardiac rhythm and the incidence and risk of embolism after PMC. Next our current criteria for indication of the maze procedure, which included duration of AF less than 10 years, voltage of f wave on electrocardiography greater than 0.1 mV, cardiothoracic ratio less than 70%, and left atrial dimension less than 70 mm, were applied to all patients. These criteria were satisfied by 190 patients of PMC (PMC group) and 114 patients of MVS/maze (MVS/maze group) and the early and late results of the two groups were compared. RESULTS: Thirty-eight patients suffered from embolic complications after PMC. Of these 33 patients experienced AF before intervention. The actuarial embolism-free rate at 10 years was 81.9% in patients with AF before PMC and 92.9% in patients with sinus rhythm before PMC (p = 0.01). Univariate predictors of embolism after PMC included previous embolic history (p = 0.01), AF (p = 0.01), pressure gradient (p = 0.01), age (p = 0.03), and mitral valve area (p = 0.04). Multivariate analysis identified AF as the independent predictor of embolism in the late follow-up period (p = 0.03). In a comparative study of the selected patients the actuarial AF-free rates after MVS/maze were 89.9% at 1 year and 85.7% at 5 years and were significantly higher than those of 17.3% at 1 year and 4.2% at 5 years after PMC (p < 0.0001). The actuarial embolism-free rate in the MVS/maze group was 98.0% at 5 years and was significantly higher than that of 84.8% at 5 years and 82.4% at 10 years in the PMC group (p = 0.01). CONCLUSIONS: PMC alone is not sufficient with regard to sinus rhythm recovery and prevention of embolism. Surgical treatment concomitant with the maze procedure may be beneficial for patients with AF.

Atrial Fibrillation↗

Should the transverse aortic arch be replaced simultaneously with aortic root replacement for annuloaortic ectasia in Marfan syndrome?

OBJECTIVE: The purpose of this study was to determine, on the basis of the late fate of the intact aortic arch with abnormal tissue after aortic root replacement, whether the intact aortic arch should be replaced prophylactically at the time of aortic root replacement for annuloaortic ectasia in Marfan syndrome. METHODS: A retrospective review was performed in 85 patients with Marfan syndrome who underwent aortic root replacement for annuloaortic ectasia with or without aortic dissection (mean age 37 years, range 19-61 years). These 85 patients were divided into four groups according to the postoperative condition of the residual aorta. In group I (n = 47), the patients underwent aortic root replacement for annuloaortic ectasia with or without localized dissection in the ascending aorta. In these patients the residual aorta, including the aortic arch, was therefore intact. In group II (n = 10), the aortic arch was intact, although the descending thoracic aorta was dissected because of the preoperative type B dissection. In groups III and IV, the patients had type A dissection involving the transverse arch associated with annuloaortic ectasia. In group III (n = 13), residual dissection existed in the descending thoracic aorta after concomitant total arch replacement. In group IV (n = 15), the aortic arch and the descending thoracic aorta were dissected. RESULTS: There were 5 early deaths (3 in group I, 1 in group II, and 1 in group III). Subsequent operations were required in 10, 5, 6, and 7 cases in groups I, II, III, and IV, respectively. Regarding the aortic arch, only 2 of 53 survivors of the initial hospitalization with an intact aortic arch (groups I and II) underwent subsequent total arch replacement for the onset of dissection in the aortic arch, and 4 of 14 survivors of the initial hospitalization with a residual dissecting arch (group III) needed subsequent total arch replacement. Actuarial freedom from arch repair among patients with an intact aortic arch (91% at 15 years) was significantly higher than that among patients with a residual dissecting arch (49% at 15 years, P =.0078). CONCLUSIONS: The incidence of new dissection in the residual intact arch after aortic root replacement was extremely low. Therefore prophylactic replacement of the intact arch does not appear to be necessary at aortic root replacement for annuloaortic ectasia in Marfan syndrome.

Actuarial Analysis↗

Implantation of collar-reinforced sumit valve for patient with large calcified mass obstructing the mitral valve orifice.

A 56-year-old female had a severely calcified mitral valve annulus and a huge subvalvular mass. To avoid critical damages of the coronary artery and left ventricle, the annular calcification and the part of the mass adherent to the left ventricle were not resected. Then we performed mitral valve replacement using SuMit valve and collared reinforcement technique with xenopericardium without any major complications. The SuMit valve is designed to be placed in a supraannular position, and is useful to prevent valves from getting stuck.

Calcinosis↗

Early results of complete off-pump coronary revascularization using left internal thoracic artery with composite radial artery.

OBJECTIVE: Off-pump coronary artery bypass (OPCAB) using the left internal thoracic artery (LITA) with a composite radial artery (RA) was employed for arterial revascularization in order to minimize neurological complication. METHODS: Sixty-one patients underwent OPCAB using the LITA with a composite RA. Angiography was performed in all patients at two weeks postoperatively. RESULTS: The mean number of distal anastomoses was 3.2 +/- 0.4. A Y-composite graft was used in 55 patients, and K-composite graft was used in the other 6 patients. There was no hospital death, no neurological complication nor deep sternal infection. Furthermore, there was no episode of perioperative myocardial infarction nor hypoperfusion syndrome. Patients have been angina-free during a mean follow-up period of 1 year. The graft patency of the LITA to the left anterior descending artery (LAD) was 100% (61/61 anastomoses). The RA became occluded in 4 patients, and the patency rate was 95.6% (130/136 anastomoses). String or coronary-coronary bypass resulting from flow competition was observed in the LITA of 6 patients and in the RA of 13 patients. The string of the LITA occurred in the segment distal from the anastomosis with the composite RA. The string or coronary-coronary bypass was observed more often in cases in which the recipient coronary artery had less than 75% stenosis. CONCLUSION: OPCAB using only the LITA with a composite RA can be successfully and safely performed in patients with multivessel disease. Late postoperative follow-up of the flow competition is necessary to delineate the significance of flow competition.

Aged↗

Durability and outcome of aortic valve replacement with mitral valve repair versus double valve replacement.

BACKGROUND: The purpose of this study was to evaluate morbidity and mortality after double valve replacement (DVR) and aortic valve replacement with mitral valve repair (AVR + MVP). METHODS: From 1977 to 2000, 379 patients underwent DVR (n = 299) or AVR + MVP (n = 80). Actuarial survival and freedom from reoperation were determined by the Kaplan-Meier method. Potential predictors of mortality and reoperation were entered into a Cox multiple regression model. Propensity score was introduced for the multivariable regression modeling for adjustment of a selection bias. RESULTS: Survival 15 years after surgery was similar between the groups (DVR, 81% +/- 3%; AVR + MVP, 79% +/- 7%; p = 0.44). Freedom from thromboembolic event at 15 years was similar between the groups (p = 0.25). Freedom from mitral valve reoperation at 15 years was significantly better for the DVR group (54% +/- 5%) as compared with the AVR + MVP group (15% +/- 6%; p = 0.0006), primarily due to progression of mitral valve pathology and early structural deterioration of bioprosthetic aortic valve used for patients with AVR + MVP. After AVR + MVP, freedom from mitral reoperation at 15 years was 63% +/- 16% for nonrheumatic heart diseases, and 5% +/- 5% for rheumatic disease (p = 0.04). CONCLUSIONS: Although both DVR and AVR + MVP provided excellent survival, DVR with mechanical valves should be the procedure of choice for the majority of patients because of lower incidence of valve failure and similar rate of thromboembolic complications compared with AVR + MVP. MVP should not be performed in patients with rheumatic disease because of higher incidence of late failure.

Actuarial Analysis↗

Early and late stroke after mitral valve replacement with a mechanical prosthesis: risk factor analysis of a 24-year experience.

OBJECTIVE: We evaluated risk factors for mortality and stroke after mechanical mitral valve replacement between May 1977 and December 2001. METHODS: Early and late mortality and stroke were assessed. Potential predictors of mortality and stroke were entered into a Cox proportional hazards model. Actuarial survival and freedom from stroke were determined by a log-rank test. RESULTS: Mitral valve replacement was performed in 812 patients. Concomitant procedures included left atrial appendage closure in 493 (61%) patients, tricuspid annuloplasty-replacement in 348 (43%) patients, maze procedure in 185 (23%) patients, plication of the left atrium in 148 (18%) patients, and other procedures in 151 (19%) patients. Five-year actuarial survival was 91.1% +/- 2.3%. Freedom from stroke at 8 years was significantly better in patients with sinus rhythm versus atrial fibrillation (P <.001). Ninety-nine percent of patients with mitral valve replacement combined with a maze procedure were free from stroke, whereas only 89% of patients with mitral valve replacement alone were free from stroke at 8 years after surgical intervention. Seventy-two patients had late stroke; sixty-five patients (90%) were in atrial fibrillation, and 47 (65%) patients had the left atrial appendage closed. Multivariate analysis showed that late atrial fibrillation (odds ratio, 3.39; 95% confidence interval, 1.72-6.67; P =.0001) and omission of the maze procedure (odds ratio, 3.40; 95% confidence interval, 1.14-10.14; P =.003) were the significant risk factors for late stroke. CONCLUSIONS: Persistent atrial fibrillation was the most significant risk factor for late stroke after mechanical mitral valve replacement. Restoration of sinus rhythm with a maze procedure nearly eliminated the risk of late stroke, whereas neither closure of the left atrial appendage nor therapeutic anticoagulation prevented this complication.

Adolescent↗

In vivo evaluation of a MPC polymer coated continuous flow left ventricular assist system.

The aim of this study was the evaluation of the thrombogenicity and the biocompatibility of the SunMedical EVAHEART left ventricular assist system (LVAS) coated with 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer compared to a diamond-like carbon (DLC) coating. Four calves were implanted with the MPC polymer-coated LVAS. Eight calves were implanted with DLC coated LVAS. The thrombogenicity and biocompatibility of the pumps were evaluated. At explant, 60.0 +/- 37.2% (5-85%) of the pump surface area was still coated with MPC polymer after the duration of 45.0 +/- 32.0 days. In 1 out of 4 MPC and 2 out of 8 DLC coated pumps, there was a very small amount of thrombus around the seal ring; otherwise the blood contacting surfaces were free of thrombus. Major organs were normal except for a few lesions in kidneys from both groups. The MPC polymer coated EVAHEART LVAS seems to have low thrombogenicity and high biocompatibility similar to the DLC coated system. The current study demonstrated that the MPC polymer coating shows great promise for being used as an antithrombogenic substrate for the LVAS due to its ease of application, significant cost benefit, and reduction in anticoagulation therapy in acute postoperative period.

Animals↗

Early adaptation of the left internal thoracic artery as a blood source of y-composite radial artery grafts in off-pump coronary artery bypass grafting.

OBJECTIVE: Y-composite grafting with the radial artery (RA) is often used in off-pump coronary artery bypass grafting (OPCAB). However, the early flow reserve of the left internal thoracic artery (LITA) as a blood source of the Y-composite RA graft has not been delineated. METHODS: The size of the LITA was examined angiographically in 42 patients who underwent OPCAB using LITA and Y-composite RA grafting between June 2000 and February 2002. In these patients, the LITA was used as a blood source of the Y-composite RA graft. The mean patient age +/- SD was 67 +/- 8 years. The average number of d i stal anastomoses was 3.2 +/- 0.7. Total coronary revascularization was carried out in 34 patients with only LITA and Y-composite RA grafting. RA grafting was used for revascularization of the circumflex artery alone in 5 patients, for the right coronary artery system (RCS) alone in 6 patients, and for both the circumflex and the RCS in 23 patients. The average number of distal anastomoses using the RA was 1.9 +/- 0.7. Flow measurements of the proximal LITA were achieved intraoperatively with a transit-time flowmeter. The diameters of the LITA before and after the operation were measured angiographically. Intraoperative flow volume was correlated with the ratio of the LITA diameters before and after the operation. RESULTS: The mean flow rate of the LITA was 61 +/- 35 mL/min (range, 9-196 mL/min). The mean diameters of the LITA before and after the operation were 1.97 +/- 0.36 mm and 2.74 +/- 0.60 mm, respectively. The mean ratio of the LITA diameter after the opera t ion to that before the operation was 1.43 +/- 0.27. The intraoperative flow volume was positively correlated with the ratio of LITA diameters (r = 0.414; P =.006). CONCLUSION: These results demonstrate the early adaptation of the LITA as a blood source of the Y-composite RA graft in OPCAB and the rationale for using the LITA as a single blood source for total coronary artery revascularization.

Aged↗