Mechanism of diastolic mitral regurgitation in candidates for cardiac resynchronization therapy.

It was hypothesized that restricted diastolic leaflet motion is implicated not only in the mechanism of systolic mitral regurgitation (MR) but also in the mechanism of diastolic MR observed in patients with severe heart failure. Cardiac resynchronization therapy (CRT) can oppose increased mitral leaflet tethering by increasing transmitral pressure, thereby providing an opportunity to explore this hypothesis. A total of 26 consecutive candidates for CRT with diastolic MR were compared with 26 candidates without diastolic MR. Maximal diastolic mitral leaflet opening and inflow direction and measures of mitral valve apparatus (i.e., mitral annular diameters, calculated mitral annular area, and tethering distance) were assessed from the apical 4-chamber view before and during CRT. There were no significant differences in New York Heart Association functional class, ejection fraction, QRS duration, PR interval, systolic MR grade, or 2-dimensional geometry of the mitral valve apparatus between the groups. Patients with diastolic MR had more restricted maximal diastolic leaflet openings (54 degrees +/- 17 degrees vs 71 degrees +/- 11 degrees , p = 0.003) and substantially smaller inflow angles (66 degrees +/- 7 degrees vs 79 degrees +/- 9 degrees , p = 0.0003) compared with patients without diastolic MR. After the institution of CRT, diastolic MR was eliminated in all patients, although there were no significant changes in any of the parameters of mitral valve apparatus. In conclusion, abnormal mitral valve tethering is a constitutive element of the mechanism of diastolic MR in patients with left ventricular dysfunction. Its acute resolution after CRT does not seem to be caused by changes in mitral valve geometry but rather by an increase in transmitral closing forces.

Cardiac Pacing, Artificial↗

Improvement of congestive heart failure by upgrading of conventional to resynchronization pacemakers.

AIMS: To compare the clinical response of patients with right ventricular apical pacing (RVAP) upgraded to cardiac resynchronization therapy (CRT) to that of previously nonpaced heart failure (HF) patients who had de novo CRT implantation. BACKGROUND: The role of CRT in patients with wide QRS and HF due to RVAP is less well established than in other CRT candidates. METHODS: Ninety-eight consecutive patients with CRT were studied (mean age 70, mean ejection fraction 0.23). Group A: patients having RVAP prior to CRT implantation (n = 25), group B: patients without prior RVAP (n = 73). Clinical and echocardiographic parameters were recorded prior to, and 3 months after, CRT implantation. RESULTS: Group A patients had a wider QRS at baseline compared to group B (203 +/- 32 ms vs 163 +/- 30 ms respectively, P < 0.001), and a shorter 6-minute walking distance (222 +/- 118 m vs 362 +/- 119 m, respectively, P < 0.005). Otherwise, clinical and echocardiographic parameters were not different. At follow up, group A patients had an average 0.7 +/- 0.5 decrease in their NYHA functional class, compared to 0.3 +/- 0.7 in group B patients (P < 0.05). Six-minute walking distance increased by 93 +/- 113 m in group A, versus 36 +/- 120 m in group B (P = 0.22). There was no difference in echocardiographic response to CRT between the groups. CONCLUSIONS: HF patients with prior RVAP demonstrate clinical improvement after upgrading to CRT that is comparable, and in some aspects, even better than that observed in HF patients with native conduction delay who undergo de novo CRT implantation.

Aged↗

Prospective, randomized comparison of two biphasic waveforms for the efficacy and safety of transthoracic biphasic cardioversion of atrial fibrillation.

OBJECTIVES: The purpose of this study was to determine if there is a difference in commercially available biphasic waveforms. BACKGROUND: Although the superiority of biphasic over monophasic waveforms for external cardioversion of atrial fibrillation (AF) is established, the relative efficacy of available biphasic waveforms is less clear. METHODS: We compared the effectiveness of a biphasic truncated exponential (BTE) waveform and a biphasic rectilinear (BR) waveform for external cardioversion of AF. Patients (N = 188) with AF were randomized to receive transthoracic BR shocks (50, 75, 100, 120, 150, 200 J) or BTE shocks (50, 70, 100, 125, 150, 200, 300, 360 J). Shock strength was escalated until success or maximum energy dose was achieved. If maximum shock strength failed, patients received the maximum shock of the opposite waveform. Analysis included 141 patients (71 BR, 70 BTE; mean age 66.5 +/- 13.7. Forty-seven randomized patients were excluded because of flutter on precardioversion ECG upon blinded review (n = 25), presence of intracardiac thrombus (n = 7), or protocol deviation (n = 15). Groups were similar with regard to clinical and echocardiographic characteristics. RESULTS: The success rate was similar for the two waveforms (93% BR vs 97 BTE, P = .44), although cumulative selected and delivered energy was less in the BTE group. Only AF duration was significantly different between successful and unsuccessful patients. No significant complications occurred. CONCLUSIONS: Biphasic waveforms were very effective in transthoracic cardioversion of AF, and complication rates were low. No significant difference in efficacy was observed between BR and BTE waveforms. Impedance was not an important determinant of success for either biphasic waveform.

Aged↗

Long-term performance of screw-in atrial pacing leads: a randomized comparison of J-shaped and straight leads.

OBJECTIVE: In this prospective, randomized, control study we compared performance of J-shaped (JL) and straight atrial leads (SL) with active (screw-in) fixation mechanism, over a 5-year follow-up period. SUBJECTS AND METHODS: A total of 208 consecutive patients were randomized for implantation with a Medtronic 4568 JL model (n = 103) versus a Medtronic 4068 SL model (n = 105), and all lead-related measurements and complications were recorded. RESULTS: Lead-related complications occurred in JL and SL with similar frequency (6% and 9%, respectively, P = 0.45). Lead dislodgment occurred in 8 (7.8%) cases in SL versus none in JL (P = 0.004). Lead malfunction and excessive pacing thresholds without macrodislodgment occurred more frequently in JL (11; 10.7%) than in SL (4; 3.8%), P = 0.055. Lead material failure (insulation break) occurred only once in SL at the 5-year checkup. Most complications occurred during the first year after implantation. Other events occurred in both leads with similar frequency and included: death in 39 and 35, loss of follow-up in 8 and 6, and development of atrial fibrillation in 9 and 15 patients, respectively. Of those who completed follow-up, lead impedance and pacing threshold increased significantly in both groups. P wave decreased in SL but not in JL. CONCLUSION: More dislocations occurred in SL, but were counterbalanced by more lead malfunctions and excessive pacing thresholds in the JL group. Both leads demonstrated minor deterioration in electrical measurements during follow-up, with only 1 case of lead material failure in SL. Overall, both groups demonstrated favorable lead performance throughout follow-up.

Aged↗

Programmable multiple pacing configurations help to overcome high left ventricular pacing thresholds and avoid phrenic nerve stimulation.

BACKGROUND: High left ventricular pacing (LVP) thresholds and phrenic nerve stimulation (PNS) are common problems with cardiac resynchronization (CRT). Newer systems capable of multiple LVP configurations may help overcome these problems without the need for reoperation. METHODS: CRT systems capable of multiple LVP configurations (Guidant models H155 and H145) were implanted in 43 patients (study group). An additional 49 patients (control group) received CRT systems (Guidant, Medtronic, Biotronik, St. Jude Medical, various models) lacking this feature. RESULTS: Overall, acute high (> or =2.5 V/0.5 ms) LVP thresholds were encountered in 13 (30%) of the study group, and 25 (50%) of control group patients (P = 0.03). PNS was encountered in 5 (12%) of the study group and 12 (24%) of control group patients (P = 0.13). All cases of high LVP thresholds and PNS in the study group were managed by switching to a different LVP configuration, while high thresholds remained in control group patients, and PNS was managed by replacing the lead. The CS lead was successfully placed in a lateral branch in 95% of study group, compared to only 77% of control group patients (P = 0.004). CONCLUSIONS: Multiple LVP configurations were clinically useful in a significant number of patients undergoing CRT system implantation by helping to overcome high LVP thresholds and PNS, and by providing more flexibility in placing the LV lead.

Aged↗

Long-term prognosis of inducible ventricular flutter: not an innocent finding.

BACKGROUND: The prognostic significance of ventricular flutter (VFL) induced during programmed electrical stimulation (PES) is currently unknown. METHODS: This study examined patients who had PES-induced VFL and assessed their long-term prognosis compared with patients who had inducible sustained monomorphic ventricular tachycardia (SMVT). RESULTS: Of 3414 patients undergoing PES, 74 (2%) had sustained VFL. They were compared with a group of 71 patients undergoing PES in the same time frame who had inducible SMVT. Patients with inducible VFL had a higher ejection fraction than patients with SMVT (0.39 vs 0.33; P =.05). More aggressive pacing was required for arrhythmia induction in patients with VFL, with more stimuli (2.7 +/- 0.5 vs 2.2 +/- 0.6; P <.01) and tighter S(2), S(3), and S(4) intervals. After a mean follow-up of 30 +/- 31 months, the mortality rate was 34% in patients with VFL and 30% in patients with SMVT (P =.41). No difference in the 2 groups in overall survival or a combined end point of sudden death or appropriate implantable cardioverter defibrillator shock was revealed with Kaplan-Meier analysis. CONCLUSION: The long-term prognosis of patients with inducible VFL is similar to that of patients with inducible SMVT, even when VFL is induced with a relatively aggressive protocol.

Arrhythmias, Cardiac↗

Use of automatic threshold tracking function with non-low polarization leads: risk for algorithm malfunction.

The AutoCapture (AC) function of new pacemakers (PM) from St Jude Medical (SJM) was originally recommended for use with low polarization (LP) ventricular leads only.However, recent reports have encouraged the use of the AC function with various leads, including those lacking a special LP design. The objective of this study was to analyze the reliability and safety of the AC algorithm application with different types of pacing leads. The study group comprised 30 consecutive patients with AC PMs connected to three different types of non-LP leads. Ten patients with SJM LP leads served as the control group. The study protocol included a complete AC function test using four different pulse widths (PW). The pacing threshold was independently assessed by a manual/semiautomatic check. Erratic behavior of polarization measurements with increasing PWs was demonstrated in 43% (n = 13) of the study group. Invalid polarization measurements resulted in erroneous algorithm recommendation to apply AC function in 17% (n = 5) of the study patients. Subsequent AC function activation lead to incorrect threshold determination due to missed noncapture in three patients. AC function should be applied with caution with non-LP leads. "Off label" use of these leads may cause erroneous polarization signal measurements which, in some cases, may result in incorrect pacing threshold determination, rendering a potential risk to dependent patients.

Algorithms↗

Pericarditis following permanent pacemaker insertion.

BACKGROUND: The appearance of pericarditis following insertion of a permanent pacemaker is not widely acknowledged in the literature. OBJECTIVES: To describe our experience with pericarditis following 395 permanent pacemaker implantations over 2 years. METHODS: We retrospectively reviewed the medical records of 395 consecutive patients in whom new pacing systems or pacemaker leads had been implanted over a 2 year period. We searched the records for pericarditis that developed within 1 month after pacemaker implantation according to the ICD-9 code. The incidence, clinical picture, response to treatment, and relationship to lead design and location were studied. RESULTS: Eight cases (2%) of pericarditis following implantation were detected. Clinical manifestations in all patients were similar to those of post-pericardiotomy syndrome and included chest pain (n = 7), friction rub (n = 1), fever (n = 2), fatigue (n = 2), pleural effusion (n = 2), new atrial fibrillation (n = 2), elevated erythrocyte sedimentation rate (n = 4), and echcardiographic evidence of pericardial effusion (n = 8). All affected patients had undergone active fixation (screw-in) lead implantation in the atrial position. The incidence of pericarditis with screw-in atrial leads was 3% compared to 0% in other cases (P < 0.05). CONCLUSIONS: Pericarditis is not uncommon following pacemaker implantation with active fixation atrial leads. Special attention should be paid to identifying pericardial complications following pacemaker implantation, especially when anticoagulant therapy is resumed or initiated. The use of passive fixation leads is likely to reduce the incidence of pericarditis but this issue should be further investigated.

Adrenal Cortex Hormones↗

Patients with an ICD can safely resume work in industrial facilities following simple screening for electromagnetic interference.

Patients with ICDs are commonly advised to quit industrial jobs because of concerns that strong electromagnetic fields operating in the industrial environment might interfere with ICD functions. This study was done to assess interactions between industrial equipment and ICDs, and to devise a simple low risk screening protocol. We studied 18 patients carrying nine different ICD models who were met at their workplace by a clinical technician and were asked to walk through their workplace and perform typical duties while sensing status was monitored by listening to the ICD's beeper. All devices were interrogated at the completion of testing. At follow-up, patients were contacted by phone and were asked about employment status and history of ICD discharges or syncope. One hundred eighty-four contacts with 114 types of industrial equipment in 13 different industrial facilities (including 31 contacts with arc welding machines) were monitored. Interference with ICD's function occurred in only one contact (0.5%), when ICD therapy was temporarily suspended while a worker was attaching a huge electromagnet to a crane. At follow-up 46.0 +/- 6.0 months after testing, 7 patients (41%) are still holding the same job, 7 have retired because of reasons unrelated to their ICD, and 3 patients were transferred to a nonindustrial job. None of the patients had either an ICD shock or syncope during work. The use of a simple screening procedure can safely identify sources of electromagnetic interference that may affect ICD operation, and can predict long-term safety of working in an industrial workplace for ICD patients.

Adult↗

Managing pacemaker safety alerts: experience with three successive models of a single manufacturer.

This report describes the experience of a large pacemaker center during three successive replacement operations due to safety alerts involving three models from the same manufacturer. Between March 1993 and May 1999, 210 patients were implanted with three DDD pacemaker models (Sorin Biomedica, Saluggia, Italy) that were subsequently subject to safety alerts. Pacemaker records were reviewed for complications related to device malfunction, and those secondary to the replacement procedure. Pacemaker malfunction was observed in 16.4% of units despite much lower estimates from the company (range 1-4%). With the exception of one, all units were replaced. Malfunctions were discovered in 7 of 20 pacemakers following an urgent call for follow-up issued as a result of the alert. Twenty units implanted as substitutes for those replaced following the first alert turned out to be subject to the third alert. Significant clinical consequences of malfunction occurred in 5.3% of patients including a near fatal event in one case, while complications related to the replacement procedure occurred in 8.3% of patients, including one fatality. On the issuance of a safety alert, failure rates in a particular center may be higher than published by the manufacturer, and should prompt action by the center to weigh local incidence of device failure against complications of replacement procedures. When device failure mechanism is not entirely clear, particularly in cases of successive model failures, replacement devices from a different manufacturer should be considered.

Adolescent↗

Cardiac resynchronization therapy: a new frontier in the management of heart failure.

CRT offers today another option for some patients with heart failure, side by side with more "traditional" therapies like drugs, assist devices, and heart transplantation. Clinical studies show that in properly selected patients a significant improvement in hemodynamic parameters and clinical status can be achieved by BV pacing. It is still unknown whether this type of therapy will also result in a survival benefit for patients with severe heart failure. The next few years certainly promise to be as exciting for CRT as were the last few.

Cardiac Pacing, Artificial↗

Wavelet analysis of instantaneous heart rate: a study of autonomic control during thrombolysis.

Myocardial infarction (MI) is known to elicit activation of the autonomic nervous system. Reperfusion, induced by thrombolysis, is thus expected to bring about a shift in the balance between the sympathetic and vagal systems, according to the infarct location. In this study, we explored the correlation between reperfusion and the spectral components of heart rate (HR) variability (HRV), which are associated with autonomic cardiac control. We analyzed the HR of patients during thrombolysis: nine anterior wall MI (AW-MI) and eight inferoposterior wall MI (IW-MI). Reperfusion was determined from changes in ST levels and reported pain. Reocclusion was detected in four patients. HRV was analyzed using a modified continuous wavelet transform, which provided time-dependent versions of the typically used low-frequency (LF) and high-frequency (HF) peaks and of their ratio, LF/HF. Marked alterations in at least one of the HRV parameters was found in all 18 reperfusion events. Patterns of HRV, compatible with a shift toward relative sympathetic enhancement, were found in all of the nine reperfusion events in IW-MI patients and in three AW-MI patients. Patterns of HRV compatible with relative vagal enhancement were found in six AW-MI patients (P < 0.001). Significant changes in HRV parameters were also found after reocclusion. Time-dependent spectral analysis of HRV using the wavelet transform was found to be valuable for explaining the patterns of cardiac rate control during reperfusion. In addition, examination of the entire record revealed epochs of markedly diminished HRV in two patients, which we attribute to vagal saturation.

Adult↗

ST-segment deviation following implantable cardioverter defibrillator shocks: incidence, timing, and clinical significance.

ST-segment analysis is frequently used during surgical procedures, while ST deviation is considered a sign of myocardial injury. ST deviations were reported following transthoracic and epicardial electrical shocks. The prevalence, timing, and clinical significance of ST-segment deviation following endocardial ICD shocks are discussed in this article. Twenty-eight patients undergoing 125 shock episodes during ICD implantation or testing were included. A 12-lead ECG was recorded at baseline, continuously during the first 3-10 seconds, 1 minute after test shocks, 3-10 seconds and 1 and 5 minutes after each shock given to terminate VF. ST deviation was diagnosed when the ST-segment was displaced > or = 1 mm in at least one lead compared to baseline. ST-segment deviations were observed after 49 (39%) of all shock episodes in 17 (61%) of patients. ST elevation was observed after 30 (24%) of all shock episodes, and ST depression after 31 (25%). Following 13 shock episodes in seven patients, ST-elevation and depression were observed. ST depressions occurred more frequently after shocks given to terminate VF than after lower energy test shocks (28% vs 18% respectively, P = 0.045). However, there was no significant difference in the prevalence of ST elevations between the lower or higher energy shocks. No adverse clinical events were observed in patients with or without postshock ST-segment deviation. ST-segment deviation following endocardial ICD shocks is a frequent phenomenon, occurring acutely and resolving during the first few minutes postshock. It mayhave no prognostic implications.

Defibrillators, Implantable↗