Assessment of the post-prandial distribution of intragastric contents using an automated technique.

The distribution of intragastric contents has been studied using operator-dependent methods. We devised an automated technique for determining post-prandial intragastric distribution of radiolabeled meals, based on the calculation of the 'center of activity' (CA) of the radioactivity contained in the stomach in any given scintigraphic image. Twelve healthy volunteers and eleven functional dyspepsia (FD) patients ingested a liquid meal (320 mL, 450 kcal) labeled with (99m)Technetium-phytate. Images of the stomach were acquired every 5-10 min for 2 h, and counted to determine the percentage of total activity retained in the upper half of the stomach, as visually delineated. Each image was then processed using an algorithm for calculating a CA value representing the average of image-forming points corrected by pixel number. The relative CA position along the main longitudinal axis of the stomach, as defined by a digital 'skeletonizing' process, was expressed in a '0 to 1' scale. In the FD patients, the average of all CA determinations was significantly higher than in the controls (0.56, 0.30-0.80 versus 0.48, 0.33-0.68, p < 0.05) and correlated significantly with proximal stomach retention values assessed by a visual method (R = -0.64, p < 0.001). Assessing post-prandial intragastric distribution by a novel automated method is feasible and yields reliable data, while being much less operator dependent.

Adult↗

Enteric coated magnetic HPMC capsules evaluated in human gastrointestinal tract by AC biosusceptometry.

PURPOSE: To employ the AC Biosusceptometry (ACB) technique to evaluate in vitro and in vivo characteristics of enteric coated magnetic hydroxypropyl methylcellulose (HPMC) capsules and to image the disintegration process. MATERIALS AND METHODS: HPMC capsules filled with ferrite (MnFe2O4) and coated with Eudragit were evaluated using USP XXII method and administered to fasted volunteers. Single and multisensor ACB systems were used to characterize the gastrointestinal (GI) motility and to determine gastric residence time (GRT), small intestinal transit time (SITT) and orocaecal transit time (OCTT). Mean disintegration time (t50) was quantified from 50% increase of pixels in the imaging area. RESULTS: In vitro and in vivo performance of the magnetic HPMC capsules as well as the disintegration process were monitored using ACB systems. The mean disintegration time (t50) calculated for in vitro was 25+/-5 min and for in vivo was 13+/-5 min. In vivo also were determined mean values for GRT (55+/-19 min), SITT (185+/-82 min) and OCTT (240+/-88 min). CONCLUSIONS: AC Biosusceptometry is a non-invasive technique originally proposed to monitoring pharmaceutical dosage forms orally administered and to image the disintegration process.

Adult↗

Quantitative aspects of brain perfusion dynamic induced by BOLD fMRI.

The increase of relative cerebral blood flow (rCBF) may contribute for a change in blood oxygenation level dependent signal (BOLD). The main purpose of this study is to investigate some aspects of perfusional alterations in the human brain in response to a uniform stimulation: hypercapnia induced by breath holding. It was observed that the BOLD signal increased globally during hypercapnia and that it is correlated with the time of breath holding. This signal increase shows a clear distinction between gray and white matter, being greater in the grey matter.

Blood Flow Velocity↗

Gastrointestinal transit and disintegration of enteric coated magnetic tablets assessed by ac biosusceptometry.

The oral administration is a common route in the drug therapy and the solid pharmaceutical forms are widely used. Although much about the performance of these formulations can be learned from in vitro studies using conventional methods, evaluation in vivo is essential in product development. The knowledge of the gastrointestinal transit and how the physiological variables can interfere with the disintegration and drug absorption is a prerequisite for development of dosage forms. The aim of this work was to employing the ac biosusceptometry (ACB) to monitoring magnetic tablets in the human gastrointestinal tract and to obtain the magnetic images of the disintegration process in the colonic region. The ac biosusceptometry showed accuracy in the quantification of the gastric residence time, the intestinal transit time and the disintegration time (DT) of the magnetic formulations in the human gastrointestinal tract. Moreover, ac biosusceptometry is a non-invasive technique, radiation-free and harmless to the volunteers, as well as an important research tool in the pharmaceutical, pharmacological and physiological investigations.

Administration, Oral↗

Fetal source extraction from magnetocardiographic recordings by dependent component analysis.

Fetal magnetocardiography (fMCG) has been extensively reported in the literature as a non-invasive, prenatal technique that can be used to monitor various functions of the fetal heart. However, fMCG signals often have low signal-to-noise ratio (SNR) and are contaminated by strong interference from the mother's magnetocardiogram signal. A promising, efficient tool for extracting signals, even under low SNR conditions, is blind source separation (BSS), or independent component analysis (ICA). Herein we propose an algorithm based on a variation of ICA, where the signal of interest is extracted using a time delay obtained from an autocorrelation analysis. We model the system using autoregression, and identify the signal component of interest from the poles of the autocorrelation function. We show that the method is effective in removing the maternal signal, and is computationally efficient. We also compare our results to more established ICA methods, such as FastICA.

Algorithms↗

Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetry.

Source positioning close to the tumour in high dose rate (HDR) brachytherapy is not instantaneous. An increment of dose will be delivered during the movement of the source in the trajectory to its static position. This increment is the transit dose, often not taken into account in brachytherapeutic treatment planning. The transit dose depends on the prescribed dose, number of treatment fractions, velocity and activity of the source. Combining all these factors, the transit dose can be 5% higher than the prescribed absorbed dose value (Sang-Hyun and Muller-Runkel, 1994 Phys. Med. Biol. 39 1181-8, Nath et al 1995 Med. Phys. 22 209-34). However, it cannot exceed this percentage (Nath et al 1995). In this work, we use the alanine-EPR (electron paramagnetic resonance) dosimetric system using analysis of the first derivative of the signal. The transit dose was evaluated for an HDR system and is consistent with that already presented for TLD dosimeters (Bastin et al 1993 Int. J. Radiat. Oncol. Biol. Phys. 26 695-702). Also using the same dosimetric system, the radial dose function, used to evaluate the geometric dose degradation around the source, was determined and its behaviour agrees better with those obtained by Monte Carlo simulations (Nath et al 1995, Williamson and Nath 1991 Med. Phys. 18 434-48, Ballester et al 1997 Med. Phys. 24 1221-8, Ballester et al 2001 Phys. Med. Biol. 46 N79-90) than with TLD measurements (Nath et al 1990 Med. Phys. 17 1032-40).

Alanine↗

Liver iron concentration evaluated by two magnetic methods: magnetic resonance imaging and magnetic susceptometry.

Quantification of liver iron concentration (LIC) is crucial in the management of patients suffering from certain pathologies that can produce iron overload, such as Cooley's anemia and hemochromatosis. All of these patients must control the level of iron deposits in their organs to avoid the toxicity of high LIC, which is potentially lethal. This paper describes experimental protocols for LIC measurement using two magnetic techniques: magnetic resonance imaging (MRI) and biomagnetic liver susceptometry (BLS). MRI proton transverse relaxation rate (R2) and image intensity, evaluated pixel by pixel, were used as indicators of iron load in the tissue. LIC measurement by BLS was performed using an AC superconducting susceptometer system. A group of 23 patients with a large range of iron overload (0.9 to 34.5 mgFe/g(dry tissue)) was evaluated with both techniques (MRI x BLS). A significant linear correlation (r = 0.89-0.95) was found between the LIC by MRI and by BLS. These results show the feasibility of using two noninvasive methodologies to evaluate liver iron store in a large concentration range. Both methodologies represent an equivalent precision.

Adolescent↗

K-band ESR spectra of calcite stalagmites from southeast and south Brazil.

Samples of calcite stalagmites from Caverna Santana (Sao Paulo State) and Caverna Botuvera (Santa Catarina State), southeastern and southern Brazil, respectively, were studied by electron spin resonance (ESR). The more common microwave frequency (X-Band, 9.5 GHz) as well as higher frequency K-band, 24 GHz were employed for the determination of the age of the samples. Even after extensive signal averaging, the dosimetric signal is not very well defined in the X-band (9.5 GHz). Using the K-band spectrometer it was possible to clearly identify the 6 hyperfine lines of Mn2+ and other paramagnetic centers in the g=2 region: SO2- and CO2- radicals. The use of high microwave frequency gives better S/N and spectral resolution making the identification of the dosimetric signal easier. The total dose (TD) or equivalent dose (ED) deposited in the samples was 2.3+/-0.3 Gy and 1.7+/-0.4 Gy for Caverna Botuvera samples and 2.6+/-0.7 Gy for the sample of Caverna Santana, giving an age of 2.9+/-0.7 ky, 2.1+/-0.8 ky and 3+/-1 ky, respectively. These first results are compatible with U/Th analysis. Due to the low S/N precision, measurements were possible only with the use of secondary standard composed on Mn2+ lines, naturally present in this sample.

Journal Article↗

ESR dating at K and X band of northeastern Brazilian megafauna.

The archaeological dose (AD) was measured in three tooth samples of giant mammals that belonged to Brazilian megafauna using electron spin resonance (ESR) spectroscopy at X-band (nu approximately 9.5 GHz) and K-band (nu approximately 24 GHz). Samples were collected in Lagoa de Dentro, Puxinanã city in Paraiba, a northeast state in Brazil and were identified as Haplomastodon waringi (Holland) (two teeth) and one tooth sample of Xenorhinotherium bahiense (Cartele and Lessa). The average AD led to an age for the Haplomastodon samples of 11.6 ky bp. For one sample (Haplomastodon) K-band was also employed to evaluate the AD. The K-band spectrum had three components, determined using spectral simulation as follows: a wide isotropic line with g factor 2.0048, an orthorhombic line with g(x)=2.0034, g(y)=2.0022 and g(z)=1.9974, and another isotropic line with g factor 2.0008. The amplitude of these three signals increase with the added dose and the average dose found was 26+/-5 Gy. This result is compatible with the AD determined with X-band 21+/-3 Gy.

Age Determination by Teeth↗

K-band EPR dosimetry: small-field beam profile determination with miniature alanine dosimeter.

The use of small-size alanine dosimeters presents a challenge because the signal intensity is less than the spectrometer sensitivity. K-band (24 GHz) EPR spectrometer seems to be a good compromise between size and sensitivity of the sample. Miniature alanine pellets were evaluated for small-field radiation dosimetry. Dosimeters of DL-alanine/PVC with dimensions of 1.5 mm diameter and 2.5 mm length with 5 mg mass were developed. These dosimeters were irradiated with 10 MV X-rays in the dose range 0.05-60 Gy and the first harmonic (1h) spectra were recorded. Microwave power, frequency and amplitude of modulation were optimized to obtain the best signal-to-noise ratio (S/N). For beam profile determination, a group of 25 dosimeters were placed in an acrylic device with dimensions of (7.5 x 2.5 x 1)cm3 and irradiated with a (3 x 3)cm2 10 MV X-rays beam field size. The dose at the central region of the beam was 20 Gy at a depth of 2.2 cm (build up for acrylic). The acrylic device was oriented perpendicular to the beam axis and to the gantry rotation axis. For the purposes of comparison of the spatial resolution, the beam profile was also determined with a radiographic film and 2 mm aperture optical densitometer; in this case the dose was 1 cGy. The results showed a similar spatial resolution for both types of dosimeters. The dispersion in dose reading was larger for alanine in comparison with the film, but alanine dosimeters can be read faster and more directly than film over a wide dose range.

Alanine↗

A new 2 methylalanine-PVC ESR dosimeter.

The use of polyvinyl chloride (PVC) as a binder to 2-methylalanine (2MA) dosimeters was investigated. It was recently shown by Olsson et al. (Radiat. Res. 157 (2002) 113), that 2MA is approximately 70% more sensitive than L-alanine which makes this substance a good candidate to replace alanine in ESR dosimetry. PVC is a low yield material for free radical production by ionizing radiation and a good binding material easily processed and widely available. PVC can be prepared at room temperature and mixed up to 50% in weight with 2MA to produce a pellet stable in mass and physical dimensions, in large quantities and with low background signal. Pure PVC pellet irradiated at 50 Gy gave weaker ESR signals compared to 2MA at the region of spectral interest. Spectrometer settings such as microwave power, and modulation amplitude were optimized for the measurements. This dosimeter production scheme allows the addition of Mn2+ ions for an internal reference signal, leading to a self-calibrated dosimeter (J. Radional. Nucl. Chem. 240 (1999) 215).

Aminoisobutyric Acids↗

Disintegration of magnetic tablets in human stomach evaluated by alternate current biosusceptometry.

Oral administration is the most convenient route for drug therapy. The knowledge of the gastrointestinal transit and specific site for drug delivery is a prerequisite for development of dosage forms. The aim of this work was to demonstrate that is possible to monitor the disintegration process of film-coated magnetic tablets by multi-sensor alternate current Biosusceptometry (ACB) in vivo and in vitro. This method is based on the recording of signals produced by the magnetic tablet using a seven sensors array and signal-processing techniques. The disintegration was confirmed by signals analysis in healthy human volunteers' measurements and in vitro experiments. Results showed that ACB is efficient to characterize the disintegration of dosage forms in the stomach, being a research tool for the development of new pharmaceutical dosage forms.

Adult↗

Adaptive, autoregressive spectral estimation for analysis of electrical signals of gastric origin.

The electrical activity of the human stomach, which normally shows a frequency of about 0.05 Hz, may be studied non-invasively by either cutaneous electrogastrography (EGG) or surface magnetogastrography (MGG). Detection of changes in frequency with time may be useful to characterize gastric disorders. The fast Fourier transform (FFT) has been the most commonly used method for the automated spectral analysis of the signals obtained from the EGG or the MGG. We have used an autoregressive (AR) parametric spectrum estimator to analyse simulated signals of gastric electrical activity, and to evaluate the results of human studies using EGG and MGG. In comparison with the FFT, our results showed that the AR spectrum estimator provided more detailed qualitative information about frequency variations of short duration simulated signals than the FFT. In the human studies, the AR estimator was as good as the conventional FFT methods in detecting physiological changes in frequency and in identifying abnormal recordings. We conclude that the AR spectral estimator may provide a better qualitative analysis of frequency variations in small portions of the signal, and is as useful as the FFT to analyse human EGG or MGG studies.

Eating↗

Evaluation of a high dose to a finger from a 60Co accident.

Electron spin resonance and fluorescence in situ hybridization were used to evaluate the dose to the finger of a worker who accidentally touched a radiotherapy 60Co therapy source in November 1995. In September 1999, the middle finger was amputated. We estimated the dose to the bone of the finger to be 6.4 +/- 0.5 Gy using the electron spin resonance additive dose method and a corrected dose of about 20 +/- 3 Gy could be inferred by translocation analysis in peripheral lymphocytes using the fluorescence in situ hybridization method. This retrospective dosimetry was performed for the victim 4 y after the accident, but the compatibility of the results obtained by physical and biological methods reinforce their validity, although in the case of partial-body exposure the biological method has limitations and demonstrates the need to find appropriate correction factors.

Adult↗

Spatial resolution of magnetic resonance imaging Fricke-gel dosimetry is improved with a honeycomb phantom.

The spatial accuracy of magnetic resonance imaging (MRI) Fricke-gel dosimetry is limited by diffusion of ferric ions. This paper describes a honeycomb structure to limit diffusion of Fe3+ ions in a three-dimensional phantom. Such a phantom containing the dosimeter gel was irradiated to a known dose distribution. Maps of dose distributions were produced from the MR images acquired at 2 and 24 hours after the dose was given. The dose distribution maps verified that the honeycomb structure precludes ion diffusion from one honeycomb cell to another, thus improving the usefulness of MRI Fricke-gel dosimetry.

Cobalt Radioisotopes↗

Preliminary evaluation of second harmonic direct detection scheme for low-dose range in alanine/EPR dosimetry.

The usefulness of a direct detection scheme of the second harmonic (2h) overmodulated signal from irradiated alanine in EPR dosimetry was studied. For this purpose, a group of DL-alanine/paraffin cylindrical pellets was produced. The dosimeters were irradiated with a 60Co radiotherapy gamma source with doses of 0.05, 0.1, 0.5, 1 and 5 Gy. The EPR measurements were carried out in a VARIAN-E4 spectrometer operating in X-band with optimized parameters to obtain highest amplitude signals of both harmonics. The 2h signal was detected directly at twice the modulation frequency. In preliminary results, the 2h showed some advantages over the 1 h such as better resolution for doses below 1 Gy, better repeatability results and better linear behaviour in the dose range indicated.

Alanine↗

Theta oscillations and human navigation: a magnetoencephalography study.

Magnetoencephalography (MEG) was used to study alpha and theta activity while subjects navigated through a computer-generated virtual reality town. The subjects were first allowed to explore the environment freely. They then had to navigate from a starting point to a destination, knowing that an obstruction would appear at one of several possible locations along the main route and force them to take a detour. Spatiotemporal analysis of the theta and alpha bands were performed (1) prior to the start of navigation, (2) from the start of navigation until the obstruction was encountered, (3) during the time subjects were contemplating a detour and were not navigating, and (4) from the resumption of navigation until the destination was reached. In all subjects, theta power was strongest during the two periods of navigation. The peak frequency of the oscillations was approximately 3.7 Hz. Control studies consisted of a motor task similar to that required for navigation, passive viewing of a tour through the same virtual reality town, and a mental concentration task. No consistent increases in theta power were seen in the MEG during any of the control tasks. The results suggest an association between theta rhythm and the performance of navigational tasks in humans.

Adult↗