PubMed Health⌕ Search

Biomedical subjects

Otto S Wolfbeis

Publications and source records attributed to Otto S Wolfbeis.

At least 19 recordsLinked to original sources

A resonance energy transfer immunoassay based on a thiol-reactive ruthenium donor dye and a longwave-emitting acceptor.

A novel immunoassay is described that applies a thiol-reactive ruthenium metal-ligand complex as the donor dye in a luminescence energy transfer (LET) detection scheme. Unlike amine-reactive labels, the LET with a thiol label allows improved specificity and better reproducibility of labelling positions on proteins, because the number of reactive thiol groups of proteins is distinctly smaller. This helps to reduce the risk of over-labelling and self-quenching of the fluorophore. The synthesis of the thiol label was significantly improved, resulting in almost quantitative yields of pure product. The absorption and emission maxima of the ruthenium donor dye are at 460 nm and 600 nm, respectively, and a Stokes' shift of 140 nm warrants distinct separation of excitation and emission wavelengths even in turbid samples. A cyanine dye with an absorption maximum at 642 nm was chosen as the acceptor label because it has good overlap with the emission spectrum of the donor label. The emission of the acceptor peaks at 660 nm, thus further increasing the Stokes' shift (to an overall 200 nm). The quantification of anti-HSA with the LET immunoassay is possible with this new approach at concentrations as low as 220 pmol L(-1).

Biochemistry↗

Temperature-sensitive europium(III) probes and their use for simultaneous luminescent sensing of temperature and oxygen.

Highly photostable and strongly luminescent europium(III) beta-diketonate complexes are presented that can act as new probes for optical sensing of temperature. They can be excited with the light of a 405-nm LED and possess strong brightnesses. The decay times of the probes contained in a poly(vinyl methyl ketone) film and in poly(tert-butyl styrene) microparticles are highly temperature-dependent between 0 and 70 degrees C. The temperature-sensitive microparticles were dispersed, along with oxygen-sensitive microbeads consisting of a palladium porphyrin oxygen indicator in poly(styrene-co-acrylonitrile), in a thin layer of a hydrogel to give a dually sensing material which is excitable by a single light source. The two emissions can be separated by appropriate optical filters. The response to oxygen and temperature is described by 3D plots, and unbiased values can be obtained for temperature and oxygen, respectively, from the two luminescence signals if refined in an iteration step. The sensing scheme is intended for use in temperature-compensated sensing of oxygen, in contactless sensing of oxygen and temperature in (micro)biological and medical applications, in high-resolution oxygen profiling, and for simultaneous imaging of air pressure and temperature in wind tunnels.

Europium↗

A novel method for time-resolved fluorimetric determination and imaging of the activity of peroxidase, and its application to an enzyme-linked immunosorbent assay.

A new type of fluorescence assay for the determination of peroxidase (POx) activity is presented. The assay is based on the indication of the enzymatic consumption of H(2)O(2) (HP), using a fluorescent europium-tetracycline (Eu(3)TC) complex as indicator. On addition of HP, this complex forms a highly fluorescent adduct (Eu(3)TC-HP), which is decomposed in the presence of POx to form the weakly fluorescent europium-tetracycline (Eu(3)TC). Hence, the activity of the enzyme can be directly determined by means of the luminescent Eu(3)TC complex as indicator. The POx assay demonstrated herein was elaborated starting from a spectral characterization of the complex systems involved. Due to the long lifetime of lanthanide luminescence, both steady-state and time-resolved luminescence assays can easily be performed. The time-resolved assay can quantify POx in the range from 4.0 x 10(-5) to 5.9 x 10(-3) U mL(-1), with a limit of detection of 1.0 x 10(-5) U mL(-1). The effects of POx inhibitors such as cyanide, hydroxylamine, and azide have also been studied. In addition, a time-resolved fluorescent detection method for a POx-based enzyme-linked immunosorbent assay (ELISA) has been developed, which is demonstrated in a sandwich model assay with bovine IgG serving as analyte. Furthermore, a time-resolved fluorescent imaging method is demonstrated that makes use of a straightforward imaging set-up adjusted to the optical properties of the europium reagent.

Animals↗

Electrocatalytic activity of DNA on electrodes as an indication of hybridisation.

Electron transfer between metal electrodes and ferro/ferricyanide is completely suppressed at low ionic concentration. We describe here a new phenomenon related to this reaction: an immobilisation of thiolated single-stranded DNA on gold electrodes retains this activity at low ionic strength up to the level corresponding to the high ionic strength. In contrast, a hybridisation of the complementary DNA with the thiolated single-stranded DNA followed by a binding onto the electrodes, attenuated the electrocatalytic effect. These effects can be used for discrimination between single-stranded DNA and double-stranded DNA and for semi-quantitative measurement of complementary DNA in a sample.

Base Pairing↗

Modified dual lifetime referencing method for simultaneous optical determination and sensing of two analytes.

Simultaneous fluorometric sensing of two analytes becomes possible using a modified dual lifetime referencing (m-DLR) method. In this scheme, two luminescent indicators are needed that have overlapping absorption and emission spectra but largely different decay times. They are excited by a single light source, and both emissions are measured simultaneously. In the frequency domain m-DLR method, the phase of the short-lived fluorescence of a first indicator is referenced against that of the long-lived luminescence of the second indicator. The analytical information is obtained by measurement of the phase shifts at two modulation frequencies. The method is demonstrated to work for the case of dually sensing oxygen and carbon dioxide. It benefits from simple instrumentation and optical setup. The approach is perceived to be of wide applicability. Examples include (1) analysis of two luminescent analytes, (2) analytical determinations that make use of two probes, and (3) sensing of two species such as carbon dioxide and oxygen (as demonstrated here), or oxygen and chlorophyll, provided the luminophores meet the condition of having largely different decay times and overlapping absorption and emission spectra.

Carbon Dioxide↗

Novel type of general protein assay using a chromogenic and fluorogenic amine-reactive probe.

We report on a new and simple one-reagent method for general protein assay. It makes use of one of two new reactive labeling reagents presented here (and referred to as pyrylium [Py] labels). These can be applied for both photometric and fluorometric protein assays at near neutral pHs at room temperature. The Py labels undergo a large spectral change on conjugation to the amino group of proteins and typically change their color from blue to red. Therefore, and unlike in other assays, there is no need to separate the unconjugated (blue) label from the red conjugate, which can be determined by direct photometry with a limit of detection of 1.2 microg/ml for human serum albumin. The assay can be extended to fluorometry because the fluorescence of the free Py label is weak (with a quantum yield of <1%) but increases strongly (to >40%) on conjugation. The strong fluorescence of the red conjugates can be determined directly and without interference by the blue (and weakly fluorescent) free label. The fluorometric assay resulted in a limit of detection of 60 ng/ml for bovine serum albumin (BSA). Validation of the fluorescence assay of blood plasma samples spiked with BSA gave recoveries in the range from 91 to 103%.

Amines↗

Screening scheme based on measurement of fluorescence lifetime in the nanosecond domain.

The authors demonstrate that the fluorescence lifetime of certain fluorescent labels is a useful parameter to detect affinity binding between biotin and streptavidin, as well as between biotinylated bovine serum albumin and streptavidin. The assay is performed in a microplate format, and lifetimes are determined using dye laser-induced fluorescence. Four fluorescent labels are presented that undergo a significant change in their lifetime upon affinity binding. The scheme, referred to as the fluorescence lifetime affinity assay, has several attractive features in that it requires single labeling only, represents a homogeneous assay, allows each of the 2 binding partners to be labeled, and is compatible with the standard microwell formats used in high-throughput screening.

Affinity Labels↗

Fluorescence imaging of the activity of glucose oxidase using a hydrogen-peroxide-sensitive europium probe.

A method for optical imaging of the activity of glucose oxidase (GOx) using a fluorescent europium(III) tetracycline probe for hydrogen peroxide is presented. A decay time in the microsecond range and the large Stokes shift of 210 nm of the probe facilitate intensity-based, time-resolved, and decay-time-based imaging of glucose oxidase. Four methods for imaging the activity of GOx were compared, and rapid lifetime determination imaging was found to be the best in giving a linear range from 0.32 to 2.7 m Unit/mL. The detection limit is 0.32 m Unit/mL (1.7 ng mL(-1)) which is similar to that of the time-resolved (gated) imaging using a microtiterplate reader. Fluorescent imaging of the activity of GOx is considered to be a useful tool for GOx-based immunoassays with potential for high-throughput screening, immobilization studies, and biosensor array technologies.

Biosensing Techniques↗

Double-wavelength technique for surface plasmon resonance measurements: basic concept and applications for single sensors and two-dimensional sensor arrays.

A new technique for on-line monitoring of analyte binding to sensor surfaces by surface plasmon resonance (SPR) detection is described. It is based on differential measurements using two wavelengths provided by two diode lasers. The technique is as simple and robust as the conventional SPR detection measuring the reflected radiation at fixed incidence angle, but it has the advantage of being nonsensitive to variations of the resonance width and providing essentially higher signal/noise ratios. The paper presents the first four channel prototype system for parallel 2D-monitoring at four different spots. One channel is always used as a reference to compensate temperature fluctuations and nonspecific adsorptions. Calibration with sucrose solutions revealed an absolute sensitivity of Deltan approximately 5 x 10(-6). The new technique is tested with a biotin-streptavidin binding and with hybridization/denaturation of DNA. Biotin binding to a streptavidin monolayer is detected with a signal/noise ratio of about 5, which demonstrates the high potential of the new technique for applications in drug discovery. Applications to gene analysis are tested with short oligonucleotides of the sequences used for genotyping human hepatitis C viruses. A selective response to complementary oligonucleotides is observed. The high reproducibility in subsequent cycles of hybridization/denaturation (by formamide or by heating) points out potential applications of the technique in medical diagnostics, food industry, genomics, and proteomics too.

Biosensing Techniques↗

Time-resolved fluorescent chirality sensing and imaging of malate in aqueous solution.

Chiral discrimination of malates in aqueous solutions at near-neutral pH is achieved through fluorescence measurement and imaging using the europium-tetracycline complex (EuTc) as a fluorescent probe. The method is based on the significantly different fluorescence properties of the ternary complexes (Eu-Tc-malate) formed between EuTc and the enantiomeric malates. The enantiomeric excess (ee) of chiral malates can be quantified by both steady-state and time-resolved fluorescence, using either a conventional fluorescence microplate reader or fluorescence imaging. It offers a facile and sensitive method for high-throughput chiral discrimination.

Europium↗

Determination of picomolar concentrations of proteins using novel amino reactive chameleon labels and capillary electrophoresis laser-induced fluorescence detection.

Py-1 and Py-6 are novel amino-reactive fluorescent reagents. The names given to them reflect that they consist of a pyrylium group attached to small aromatic moieties. Upon reaction with a primary amine there is a large spectral shift in the reagent, rendering them effectively fluorogenic. In this study, these reagents were used to label a test protein, (human serum albumin), and the sample was analyzed by capillary electrophoresis and laser-induced fluorescence detection. Detection limits after a 60 min labeling reaction at 22 degrees C (Py-1) and 50 degrees C (Py-6) were 6.5 ng/mL (98 pM) for Py-1 and 1.2 ng/mL (18 pM) for Py-6. Separation of immunoglobulin G (IgG), human serum albumin, lipase, and myoglobin after labeling with Py-6 were performed. The method was further modified to make it amenable to automation. Unlike many other amino reactive reagents used to label protein amino groups, reaction with Py-1 and Py-6 do not alter the charge of the protein and the advantage of this with respect to electrophoretic separations is discussed.

Amines↗

A new fluorescence resonance energy transfer pair and its application to oligonucleotide labeling and fluorescence resonance energy transfer hybridization studies.

We describe two new fluorescence resonance energy transfer (FRET) compatible labels, their covalent linkage to oligonucleotides, and their use as donor and acceptor, respectively, in FRET hybridization studies. The dyes belong to the cyanine dyes, and water solubility is imparted by a phosphonate which represents a new solubilizing group in DNA labels. They were linked to amino-modified synthetic oligonucleotides via oxysuccinimide (OSI) esters. The studies performed include binding assays, determinations of molecular distances, homogeneous competitive assays, and limits of detection, which are in the order of 5 pmol/L for a 15-mer.

Journal Article↗

Improved routine bio-medical and bio-analytical online fluorescence measurements using fluorescence lifetime resolution.

Fluorescence techniques are widely used as sensitive detection methods in bio-analytics. The use of the bio-physical parameter fluorescence lifetime additional to the spectral characteristics of fluorescence has the potential to improve fluorescence-related detection methods in terms of selectivity in signal recognition, robustness against disturbing influences, and the accessibility of novel bio-chemical process parameters. This article describes the technical set up of a time-resolving instrument with either a fixed time-gated detection principle for improved evaluation of tissue metabolism by an online monitoring of the tissue autofluorescence or a direct fluorescence lifetime detection principle for lifetime-based fluorescent assays.

Animals↗

Nonenzymatic direct assay of hydrogen peroxide at neutral pH using the Eu3Tc fluorescent probe.

A detailed study is presented on the use of an easily accessible probe (the europium-tetracycline 3:1 complex; referred to as Eu3Tc) for determination of hydrogen peroxide (HP). Eu3Tc undergoes a 15-fold increase in luminescence intensity on exposure to an excess of HP. Data are given on the time dependence of the reaction, on the pH dependence of the absorption and emission spectra of both the probe and its complex with HP, and on the effect of stoichiometry between Eu3+ and Tc on selectivity and signal change. HP can be quantified in aqueous solution of pH 6.9 over a 2-400 microM concentration range with a limit of detection of 960 nM. The assay is validated using standard additions, and mean recoveries are found to be between 97.0 and 101.8%. Species that interfere in concentrations below 1 mM include phosphate, copper(II), fluoride and citrate. The addition of detergents causes the response curves towards HP to shift to higher HP concentrations. The method is critically assessed with respect to other common optical methods for determination of HP.

Europium↗

In vivo phosphorescence imaging of pO2 using planar oxygen sensors.

OBJECTIVE: Oxygen-dependent quenching of luminescence of metal porphyrin complexes has been used to image the pO(2) distribution over tumor and normal tissue. METHODS: An experimental setup is described using a platinum(II)-octaethyl-porphyrin immobilized in a polystyrene matrix as transparent planar sensor. RESULTS: Sensitivity over a broad range is high at low pO(2) values (+/- 0.2 mm Hg at 0 mm Hg; +/- 1.5 mm Hg at 160 mm Hg pO(2)). Due to intrinsically referencing via lifetime encoding there was no modification of the sensor response in vivo in the dorsal skinfold chamber model with amelanotic melanoma (A-MEL-3) in awake hamsters when compared to the in vitro calibration. pO(2) measurements over normal tissue (25.8 +/- 5.1 mm Hg) and tumor tissue (9.2 +/- 5.1 mm Hg) were in excellent agreement with previous results obtained in this model using a surface multiwire electrode. CONCLUSIONS: Using the presented method the surface pO(2) distribution can be mapped with a high temporal resolution of approximately 100 ms and a spatial resolution of at least 25 mu m. Moreover, the transparent sensor allows the simultaneous visualization of the underlying microvasculature.

Animals↗