Fully automatic detection of corresponding anatomical landmarks in volume scans of different respiratory state.

A method is described which provides fully automatic detection of corresponding anatomical landmarks in volume scans taken at different respiratory states. The resulting control points are needed for creating a volumetric deformation model for motion compensation in radiotherapy. Prior to treatment two CT volumes are taken, one scan during inhalation, one during exhalation. These scans and the detected control point pairs are taken as input for creating the four-dimensional model by using thin-plate splines.

Algorithms↗

A simple method for labeling CT images with respiratory states.

A method is described for labeling CT images with their respiratory state by a needle, connected to the patient's chest/abdomen. By means of a leverage the needle follows the abdominal respiratory motion. The needle is visible as a blurred spot in every CT slice. The method was tested with nine patients. A series of volume scans during free breathing was performed. The detected positions of the moving needle in every single slice were compared to each other thus enabling respiratory state assignment. The tool is an inexpensive alternative to complex respiratory measuring tools for four dimensional (4D) CT and was greatly accepted in the clinic due to its simplicity.

Algorithms↗

Target motion measurement without implanted markers and its validation by comparison with manually obtained data.

For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achieving a CT with the patient on the therapy couch, a patient's treatment position is captured. We present a method to locate tumor considering internal organ motion and displacements due to respiration. We tested the method with prostate and lung patients. The method found the most probable tumor position as well as, for high-mobility tumors located in the lung, its trajectory during the respiratory cycle. The results of this novel method were validated by comparison with manually determined target position.

Female↗

Influence of calculation algorithm on dose distribution in irradiation of non-small cell lung cancer (NSCLC) collapsed cone versus pencil beam.

PURPOSE: . The influence of two different calculation algorithms ("pencil beam" [PB] versus "collapsed cone" [CC]) on dose distribution, as well as the dose-volume histograms (DVHs) of the planning target volume (PTV) and the organs at risk was analyzed for irradiation of lung cancer. MATERIAL AND METHODS: . Between 10/2001 and 02/2002 three-dimensional treatment planning was done in ten patients with lung cancer (Helax, TMS((R)), V.6.01). The PTV, the ipsilateral lung (IL) and the contralateral lung (CL) were defined in each axial CT slice (slice thickness 1 cm). Dose distributions for three-dimensional multiple-field technique were calculated using a PB and a CC algorithm, respectively. Normalization was in accordance with ICRU 50. The DVHs were analyzed relating the minimum, maximum, median and mean dose to the volumes of interest (VOI). RESULTS: . Median PTV amounted to 774 cm(3). Minimum dose within the PTV was 67.4% for CC and 75.6% for PB algorithm (p = 0.04). Using the CC algorithm, only 76.5% of the PTV was included by the 95% isodose, whereas 90.1% was included when the PB algorithm (p = 0.01) was used. Median volume of IL amounted to 1 953 cm(3). Mean dose to IL was 43.0% for CC and 44.0% for PB algorithm (p = 0.02). Median volume of IL within the 80% isodose was 19.6% for CC and 24.1% for PB algorithm (p < 0.01). Median volume of CL amounted to 1 847 cm(3). Mean dose to CL was 17.4% for CC and 18.1% for PB algorithm (p < 0.01). Volume of CL within the 80% isodose was 3.3% for CC and 4.1% for PB algorithm (p = 0.03). CONCLUSION: . The CC and PB calculation algorithms result in different dose distributions in case of lung tumors. Particularly the minimum dose to the PTV, which may be relevant for tumor control, is significantly lower for CC. Since it is generally accepted that the CC algorithm describes secondary particle transport more exactly than PB models, the use of the latter should be critically evaluated in the treatment planning of lung cancer.

Algorithms↗