An in vitro study of magnetic particle targeting in small blood vessels.

The magnetic guidance and capture of particles inside the human body, via the circulatory system, is a novel method for the targeted delivery of drugs. This experimental study confirms in vitro that a dipolar capturing device, based on high-energy magnets with an active space of 8.7 cm x 10 cm x 10 cm, retains colloidal magnetic particles (MPs) (<30 nm) injected in the capillary tubes, where flow velocities are comparable to that encountered in the capillary beds of tumours (<0.5 cm s(-1)). The build-up of the deposition of the MPs was investigated using video imaging techniques that enabled continuous monitoring of the blocking of the vessel whilst simultaneously recording the colloid's flow rate. The parameters of practical importance (length of MP deposit, time of capillary blocking) were estimated and were found to be dependent on the initial fluid velocity, the MP concentration and the distance between the capillary tube and the polar magnetic pieces. Although the tube used in this experiment is larger (diameter = 0.75 mm, length = 100 mm) than that of real capillaries (diameter = 0.01 mm, length approximately 1.5 mm), the flow velocities chosen were similar to those encountered in the capillary beds of tumours and the length/diameter ratio was approximately equal (133 for the present set-up, 100-150 for real capillaries). In these circumstances and using the same magnetic field conditions (intensity, gradient) and MPs, there is close similarity with magnetic capture in a microscopic capillary system. Moreover, the macroscopic system permits analysis of the distribution of MPs in the active magnetic space, and consequently the maximum targetable volume. This study revealed that the capture of particles within the active space was strongly influenced by the gradient of the magnetic field and the flow velocity. Thus, when the magnetic field gradient had medium values (0.1-0.3 T cm(-1)) and the fluid velocity was small (0.15 cm s(-1)), the particles were captured in small, compact and stable deposits (L < 4 cm) and the time necessary for blocking of the capillary was <150 s. Doubling the value for the flow velocity did not influence significantly either the length of MP deposits nor the blocking time. However, lower gradients (<0.1 T cm(-1)) and larger velocities (0.3-0.9 cm s(-1)) result in the formation of larger deposits (4 cm < L < 10 cm) that are unstable at the beginning of the capture process. These large deposits do become stable given sufficient time for the deposition process to take place in conjunction with a decrease in the flow rate. As a consequence, the time necessary for blocking of the capillary increased up to 450 s. Decreasing the MP concentration from 0.02 g cm(-3) to 0.005 g cm(-3) decreased the deposit lengths by approximately 20% and doubled the values of the blocking time. The maximum targetable volume obtained by the present method is approximately 350 cm(3), which corresponds to medium-sized tumours. The capillary vessels were blocked only for the situation that occurs for microcirculation within a tumour. This reduces the concentration of MPs trapped within the normal tissues, which occurs when using particles of micrometre size. This work showed the potential of using colloidal MPs and dipolar magnetic devices for treatment of human patients, when the affected sites are positioned at medium distances from the surface of the body (e.g. head, neck, breast, hands and legs).

Antineoplastic Agents↗

Ecotoxicological screening of Kenyan tannery dust using a luminescent-based bacterial biosensor.

Ecotoxicological screening of dust sampled throughout a Kenyan tannery was conducted using a luminescence (lux)-based bacterial biosensor for both solid and liquid assays. This was complemented by chemical analysis in an attempt to identify possible causative toxic components. The biosensor results showed a highly significant (p < 0.001) difference in both solid and liquid phase toxicity in samples collected from various identified sampling points in the tannery. A positive correlation was observed between results of the solid and liquid phase techniques, for most of the sampling points indicating that the toxic contaminants were bioavailable both in the solid and liquid state. However, the results generally indicated toxicity associated with liquid phase except certain areas in solid phase such as chemical handling, buffing area and weighing. The most toxic tannery area identified was the weighing area (p < 0.001), showing the lowest bioluminescence for both the solid (0.38 +/- 2.21) and liquid phases (0.01 +/- 0.001). Chromium was the metal present in the highest concentration indicating levels higher than the stipulated regulatory requirement of 0.5 mg Cr/m3 for total Cr (highest Cr concentration was at chemical handling at 209.24 mg l(-1)) in all dust samples. The weighing area had the highest Ni concentration (1.87 mg l(-1)) and the chemical handling area showed the highest Zn concentration (31.9 mg l(-1)). These results raise environmental health concerns, as occupational exposure to dust samples from this site has been shown to give rise to elevated concentrations (above the stipulated levels) of chromium in blood, urine and some body tissues, with inhalation being the main route. Health and Safety Executive (HSE), UK, and American Conference of Governmental Industrial Hygienist (ACGIH) and National Institute for Occupational Safety and Health (NIOSH), USA stipulates an occupational exposure limit of 0.5 mg Cr/m3 (8 h TWA) for total chromium. However, schedule 1 of Controls of substances hazardous to health (COSHH) regulations developed by HSE, indicate 0.05 mg m3 (8 h TWA reference periods) to be the limit for Cr (VI) exposure. The exposure limit for individual (e.g., Cr, Zn, Ni etc.) contaminants (homogeneity) was not exceeded, but potential impact of heterogeneity (multi-element synergistic effect) on toxicity requires application of the precautionary principle.

Air Pollutants, Occupational↗

Dose response modelling of Escherichia coli O157 incorporating data from foodborne and environmental outbreaks.

A human dose response model for Escherichia coli O157 would enable prediction of risk of infection to humans following exposure from either foodborne or environmental pathways. However, due to the severe nature of the disease, volunteer human dose response studies cannot be carried out. Surrogate models from Shigella fed to humans and E. coli O157 to rabbits have been utilised but are significantly different to one another. In addition data obtained by animal exposure may not be representative for human beings. An alternative approach to generating and validating a dose response model is to use quantitative data obtained from actual human outbreaks. This work collates outbreak data obtained from global sources and these are fitted using exponential and beta-Poisson models. The best fitting model was found to be the beta-Poisson model using a beta-binomial likelihood and the authors favour the exact version of this model. The confidence levels in this model encompass a previously published Shigella dose response model. The potential incorporation of this model into QMRAs is discussed together with applications of the model to help explain foodborne outbreaks.

Animals↗

Multiple sample flow through immunomagnetic separator for concentrating pathogenic bacteria.

The standard method of immunomagnetic separation for isolating pathogenic bacteria from food and environmental matrices processes 1 ml volumes. Pathogens present at low levels (<0.5 pathogenic bacteria/g) will not be consistently detected by this method. Here a multiple sample flow through immunomagnetic separator has been designed and tested to process large volume samples (50 to 250 ml). Preliminary results show >97% recovery of polydisperse magnetic particles (diameter range 1 to 8 microm) containing 29-33% w/w Fe3O4 content. Between 70 and 130 times more of the pathogenic bacteria Escherichia coli O157 is recovered from PBS compared with the standard 1 ml method. Also, the recovery of E. coli O157 from beef mince homogenates, after a 4 h incubation at 42 degrees C, is between 80 and 180 times higher than the standard 1 ml method.

Bacteria↗

Assessing the occupational risk of dust particles in the Kenyan tanning industry using rapid image processing and microscopy techniques.

The purpose of this study was to investigate the occupational hazards within the tanning industry caused by contaminated dust. A qualitative assessment of the risk of human exposure to dust was made throughout a commercial Kenyan tannery. Using this information, high-risk points in the processing line were identified and dust sampling regimes developed. An optical set-up using microscopy and digital imaging techniques was used to determine dust particle numbers and size distributions. The results showed that chemical handling was the most hazardous (12 mg m(-3)). A Monte Carlo method was used to estimate the concentration of the dust in the air throughout the tannery during an 8 h working day. This showed that the high-risk area of the tannery was associated with mean concentrations of dust greater than the UK Statutory Instrument 2002 No. 2677. stipulated limits (exceeding 10 mg m(-3) (Inhalable dust limits) and 4 mg m(-3) (Respirable dust limits). This therefore has implications in terms of provision of personal protective equipment (PPE) to the tannery workers for the mitigation of occupational risk.

Dust↗

Simulating the embolization of blood vessels using magnetic microparticles and acupuncture needle in a magnetic field.

Computer models were developed to simulate the capture and subsequent deposition of magnetic microparticles (MMPs) in a blood vessel adjacent to a ferromagnetic wire (e.g., acupuncture needle) magnetized by a uniform external magnetic field. Process parameter conditions were obtained to enable optimal capture of MMPs into the deposit. It was found that the maximum capture distance of the MMPs was within 0.5-2.0 mm when the particles were superparamagnetic and had large size (>1.0 microm) and relative large flow rates (2.5-5.0 cm/s) as in a healthy artery. It was also found that the deposits were asymmetrical and that their size was between 1.0 and 2.0 mm. For the case of lower flow rates as can be found in a tumor (<1.0 mm/s) and using small magnetite particles (0.25-2.0 microm) the maximum capture distance was larger, ranging between approximately 0.5 and 6.4 mm, depending on the blood flow rate, the radius of wire, and particle clustering. The range of embolization (deposition) in this later case was between 0.5 and 5.9 mm. The potential of this technique to generate MMPs deposits to embolize blood vessels inhibiting the blood supply and thus facilitating necrosis of tumors located deep within the patient (3-7 cm) is discussed.

Acupuncture Therapy↗