Simultaneous maximization of cell permeabilization and viability in single-cell electroporation using an electrolyte-filled capillary.

A549 cells were briefly exposed to Thioglo-1, which converts thiols to fluorescent adducts. The fluorescent cells were exposed to short (50-300 ms) electric field pulses (500 V across a 15 cm capillary) created at the tip of an electrolyte-filled capillary. Fluorescence microscopy revealed varying degrees of cell permeabilization depending on the conditions. Longer pulses and a shorter cell-capillary tip distance led to a greater decrease in the cell's fluorescence. Live/dead (calcein AM and propidium iodide) testing revealed that a certain fraction of cells died. Longer pulses and shorter cell-capillary tip distances were more deadly. An optimum condition exists at a cell-capillary tip distance of 3.5-4.5 microm and a pulse duration of 120-150 ms. At these conditions, >90% of the cells are permeabilized and 80-90% survive.

Biosensing Techniques↗

Controlling desensitized states in ligand-receptor interaction studies with cyclic scanning patch-clamp protocols.

Ligand-gated ion channels are important control elements in regulation of cellular activities, and increasing evidence demonstrates their role as therapeutic targets. The receptors display complex desensitization kinetics, occurring on vastly different time scales. This is not only important in biology and pharmacology but might also be of technological significance since populations of receptors under microfluidic control can function analogously to DRAM memory circuits. Using a novel microfluidic method, and computer modeling of the receptor state distributions, we here demonstrate that GABAA receptor populations can be controlled to display high or low EC50 values, depending on input function (i.e., the exact pattern of agonist application). The sensitivity of the receptors can be tuned up to 40-fold (beta-alanine) by the particular agonist exposure pattern. By combining patch-clamp experiments with computer modeling of receptor state distributions, we can control the assembly of receptors in desensitized states. The technique described can be used as an analytical tool to study the effect of desensitization on the activity of ion channel effectors. We describe the differential blocking effect of the competitive antagonist bicuculline on the high- and low-EC50 GABAA receptor preparations and conclude that the inhibition is dramatically dependent on how the different desensitized states are populated. Furthermore, we show that both GABA and beta-alanine, two agonists with different affinity but similar efficacy, induce the same type of desensitization behavior and memory effects in GABAA receptors.

Animals↗

Zipper dynamics of surfactant nanotube Y junctions.

We investigate the formation of Y junctions in surfactant nanotubes connecting vesicles. Based on experimental observations of the surfactant flow on the nanotubes, we conclude that a Y junction propagates with a zipperlike mechanism. The surfactants from two nanotube branches undergo 1:1 mixing at the junction, and spontaneously form the extension of the third nanotube branch. Taking into account the tension driven surfactant flow, we develop a model for the Y junction dynamics that is in quantitative agreement with the experimental data.

Lipids↗

Direct reconstitution of plasma membrane lipids and proteins in nanotube-vesicle networks.

We demonstrate here that nanotube-vesicle networks can be constructed directly from plasma membranes of cultured cells. We used a combination of dithiothreitol (DTT) and formaldehyde to produce micron-sized plasma membrane vesicles that were subsequently shaped into networks using micromanipulation methods previously used on purely synthetic systems. Only a single cell is required to derive material sufficient to build a small network. This protocol covers the advantages of reconstitution in vesicles, such as full control over the solution environment, while keeping the proteins in their original surroundings with the proper orientation. Furthermore, control of membrane protein and lipid content in the networks is achievable by employing different cell types, for example, by overexpression of a desired protein or the use of specialized cell-types as sources for rare proteins and lipids. In general, the method provides simple accessibility for functional studies of plasma membrane constituents. Specifically, it provides a direct means to functionalize nanotube-vesicle networks with desired proteins and lipids for studies of transport activity both across membranes (protein-mediated) and across nanotubes (diffusion), and substrate conversion down to the single-molecule limit. Nanotube-vesicle networks can adopt different geometries and topologies and undergo shape changes at will, providing a flexible system for changing the physical and chemical environment around, for example, a membrane protein. Furthermore, the method offers unique possibilities for extracting membrane and protein material for nanotechnological sensor and analytical devices based on lipid membrane networks.

Animals↗

Electrophoretic transport in surfactant nanotube networks wired on microfabricated substrates.

Nanofluidic devices are rapidly emerging as tools uniquely suited to transport and interrogate single molecules. We present a simple method to rapidly obtain compact surfactant nanotube networks of controlled geometry and length. The nanotubes, 100-300 nm in diameter, are pulled from lipid vesicles using a micropipet technique, with multilamellar vesicles serving as reservoirs of surfactant material. In a second step, the nanotubes are wired around microfabricated SU-8 pillars. In contrast to unrestrained surfactant networks that minimize their surface free energy by minimizing nanotube path length, the technique presented here can produce nanotube networks of arbitrary geometries. For example, nanotubes can be mounted directly on support pillars, and long stretches of nanotubes can be arranged in zigzag patterns with turn angles of 180 degrees. The system is demonstrated to support electrophoretic transport of colloidal particles contained in the nanotubes down to the limit of single particles. We show that electrophoretic migration velocity is linearly dependent on the applied field strength and that a local narrowing of the nanotube diameter results from adhesion and bending around SU-8 pillars. The method presented here can aid in the fabrication of fully integrated and multiplexed nanofluidic devices that can operate with single molecules.

Electrophoresis↗

Controlling the electrochemically active area of carbon fiber microelectrodes by the electrodeposition and selective removal of an insulating photoresist.

A new and simple method permits control of the electrochemically active area of a carbon fiber microelectrode. An electrophoretic photoresist insulates the 10-microm-diameter carbon fiber microelectrodes. Photolysis of the photoresist followed by immersion of the exposed area into a developing solution reveals electroactive carbon fiber surface. The electroactive surface area exposed can be controlled with a good degree of reproducibility.

Carbon↗

A biohybrid dynamic random access memory.

We report that GABA(A) receptors in a patch-clamped biological cell form a short-term memory circuit when integrated with a scanning-probe microfluidic device. Laminar patterns of receptor activators (agonists) provided by the microfluidic device define and periodically update the data input which is read and stored by the receptors as state distributions (based on intrinsic multistate kinetics). The memory is discharged over time and lasts for seconds to minutes depending on the input function. The function of the memory can be represented by an equivalent electronic circuit with striking similarity in function to a dynamic random access memory (DRAM) used in electronic computers. Multiplexed biohybrid memories may form the basis of large-scale integrated biocomputational/sensor devices with the curious ability to use chemical signals including odorants, neurotransmitters, chemical and biological warfare agents, and many more as input signals.

Animals↗

Controlling enzymatic reactions by geometry in a biomimetic nanoscale network.

We demonstrate that a transition from a compact geometry (sphere) to a structured geometry (several spheres connected by nanoconduits) in nanotube-vesicle networks (NVNs) induces an ordinary enzyme-catalyzed reaction to display wavelike properties. The reaction dynamics can be controlled directly by the geometry of the network, and such networks can be used to generate wavelike patterns in product formation. The results have bearing for understanding catalytic reactions in biological systems as well as for designing emerging wet chemical nanotechnological devices.

Biomimetic Materials↗

Controlled hydrogel formation in the internal compartment of giant unilamellar vesicles.

The introduction of poly(ethylene dioxythiophene) (PEDOT)/poly(styrene sulfonate) (PSS) polyelectrolyte into giant unilamellar phospholipid vesicles (GUVs) and cross-linking with Ca2+ ions to generate a hydrogel within the internal compartment are reported. The aqueous colloidal suspension of PEDOT with excess PSS was microinjected into the internal compartment of liposomes as well as networks of GUVs and lipid nanotubes. The subsequent introduction of calcium ions as cross-linking agent in order to induce hydrogel formation was achieved by three different methods: vesicle fusion, electroporation, and direct microinjection. Gel formation was probed by coinjection of fluorescent nanoparticles and tracking of Brownian motion. Particle mobility was shown to be distinctly reduced in the gel-filled vesicles. Diffusion constants for the particles were calculated from the projected movement of the particles and compared to particles in reference gels and solutions.

Letter↗

Generation of focused electric field patterns at dielectric surfaces.

We here report on a concept for creating well-defined electric field gradients between the boundaries of capillary electrode (a capillary of a nonconducting material equipped with an interior metal electrode) outlets, and dielectric surfaces. By keeping a capillary electrode opening close to a boundary between a conducting solution and a nonconducting medium, a high electric field can be created close to the interface by field focusing effects. By varying the inner and outer diameters of the capillary, the span of electric field strengths and the field gradient obtained can be controlled, and by varying the slit height between the capillary rim and the surface, or the applied current, the average field strength and gradient can be varied. Field focusing effects and generation of electric field patterns were analyzed using finite element method simulations. We experimentally verified the method by electroporation of a fluorescent dye (fluorescein diphosphate) into adherent, monolayered cells (PC-12 and WSS-1) and obtained a pattern of fluorescent cells corresponding to the focused electric field.

Animals↗

Microfluidic gradient-generating device for pharmacological profiling.

We describe an on-chip microfluidic gradient-generating device that generates concentration gradients spanning nearly 5 orders of magnitude starting from a single concentration. The exiting stream of drugs held at different concentrations remains laminar in a recording chamber and can be presented as 24 discrete solutions to a cell-based sensor. The high-performance characteristics of the device are demonstrated by pharmacological screening of voltage-gated K+ channels (hERG) and ligand-gated GABA(A) receptors using scanning-probe patch-clamp measurements. Multiple data point dose-response curves and IC50 and EC50 values were rapidly obtained, typically in less than 30 min, through its combined functionality of gradient generation and open-volume laminar flow. The device facilitates rapid pharmacological profiling of ion channel and GPCR effectors and enables the acquisition of large numbers of data points with minute sample consumption and handling.

Animals↗

Single-file electrophoretic transport and counting of individual DNA molecules in surfactant nanotubes.

We demonstrate a complete nanotube electrophoresis system (nanotube radii in the range of 50 to 150 nm) based on lipid membranes, comprising DNA injection, single-molecule transport, and single-molecule detection. Using gel-capped electrodes, electrophoretic single-file transport of fluorescently labeled dsDNA molecules is observed inside nanotubes. The strong confinement to a channel of molecular dimensions ensures a detection efficiency close to unity and identification of DNA size from its linear relation to the integrated peak intensity. In addition to constituting a nanotechnological device for identification and quantification of single macromolecules or biopolymers, this system provides a method to study their conformational dynamics, reaction kinetics, and transport in cell-like environments.

Bacteriophage phi X 174↗

A chemical waveform synthesizer.

Algorithms and methods were developed to synthesize complex chemical waveforms in open volumes by using a scanning-probe microfluidic platform. Time-dependent variations and oscillations of one or several chemical species around the scanning probe, such as formation of sine waves, damped oscillations, and generation of more complex patterns, are demonstrated. Furthermore, we show that intricate bursting and chaotic calcium oscillations found in biological microdomains can be reproduced and that a biological cell can be used as a probe to study receptor functionalities as a function of exposure to time-dependent variations of receptor activators and inhibitors. Thus, the method allows for studies of biologically important oscillatory reactions. More generally, the system allows for detailed studies of complex time-varying chemical and physical phenomena in solution or at solution/surface interfaces.

Algorithms↗

Controlling the internal structure of giant unilamellar vesicles by means of reversible temperature dependent sol-gel transition of internalized poly(N-isopropyl acrylamide).

In this work, we present preparation and basic applications of lipid-bilayer-enclosed picoliter volumes (microcontainers) of solutions of poly(N-isopropylacrylamide) (PNIPAAm). Giant unilamellar vesicles (GUVs) were prepared from phospholipids using a standard swelling procedure and subsequently surface immobilized. Clear, slightly viscous solutions of PNIPAAm of varying concentration in aqueous buffer were directly pressure-microinjected into the GUVs, using a submicrometer-sized, pointed capillary. The GUV was subjected to changing temperature over a 21-40 degrees C range. The typical phase transition of the polymeric material upon heating and cooling across the lower critical solution temperature was followed using optical microscopy and shown to be reversible over multiple sequential heating/cooling cycles without compromising the integrity of the GUV membrane. Fluorescent, carboxylic acid modified 200 nm latex beads, co-injected with the PNIPAAm solution, were temperature-reversibly immobilized during the phase transition, practically freezing the Brownian motion of the entrapped particles in the volume. Furthermore, a co-injected water soluble fluorescent polysaccharide-dye conjugate was shown not to migrate from the aqueous phase into the hydrophobic polymer part upon heating, whereas the fluorescent beads were completely but reversibly immobilized in the hydrophobic domains of dense polymer agglomerates. The system reported here provides a feasible method for the reversible stabilization and solidification of GUV interior volumes, e.g., as a micrometer-sized model system for controlled drug release.

Journal Article↗

Controlled initiation of enzymatic reactions in micrometer-sized biomimetic compartments.

We present a technique to initiate chemical reactions involving few reactants inside micrometer-scale biomimetic vesicles (10(-12) to 10(-15) L) integral to three-dimensional surfactant networks. The shape of these networks is under dynamic control, allowing for transfer and mixing of two or several reactants at will. Specifically, two nanotube-connected vesicles were filled with reactants (substrate and enzyme, respectively) by microinjection. Initially, the vesicles are far apart and any diffusive mixing (on relevant experimental time scales) between the contents of the separated vesicles is hindered because of the narrow diameter and long axial extension of the nanotube. To initiate a reaction, the vesicles were brought close together, the nanotube was consumed by the vesicles and at a critical distance, the nanotube-vesicle junctions were dilated leading to formation of one spherical reactor, and hence mixing of the contents. We demonstrate the concept using a model enzymatic reaction, which yields a fluorescent product (two-step hydrolysis of fluorescein diphosphate by alkaline phosphatase), where product formation was measured as a function of time using a FRAP fluorescence microscopy protocol. By comparing the enzymatic activity with bulk measurements, the enzyme concentration inside the vesicle could be determined. Reactions could be followed for systems having as few as approximately 15 enzyme molecules confined to a reactor vesicle. To describe the experiments we use a simple diffusion-controlled reaction model and solve it using a survival probability approach. The agreement with experiment is qualitative, but the model describes the trends well. It is shown that the model correctly predicts (i) single-exponential decay after a few seconds, and (ii) that the substrate decay constant depends on the number of enzymes and geometry of reaction container. The numerical correction factor Lambda is introduced in order to ensure semiquantitative agreement between experiment and theory. It was shown that this numerical factor depends weakly on vesicle radius and number of enzymes, thus it is sufficient to determine this factor only once in a single calibration measurement.

Alkaline Phosphatase↗

Fluid mixing in growing microscale vesicles conjugated by surfactant nanotubes.

This work addresses novel means for controlled mixing and reaction initiation in biomimetic confined compartments having volume elements in the range of 10(-12) to 10(-15) L. The method is based on mixing fluids using a two-site injection scheme into growing surfactant vesicles. A solid-state injection needle is inserted into a micrometer-sized vesicle (radius 5-25 microm), and by pulling on the needle, we create a nanoscale surfactant channel connecting injection needle and the vesicle. Injection of a solvent A from the needle into the nanotube results in the formation of a growing daughter vesicle at the tip of the needle in which mixing takes place. The growth of the daughter vesicle requires a flow of surfactants in the nanotube that generates a flow of solvent B inside the nanotube which is counterdirectional to the pressure-injected solvent. The volume ratio psi between solvent A and B inside the mixing vesicle was analyzed and found to depend only on geometrical quantities. The majority of fluid injected to the growing daughter vesicle comes from the pressure-based injection, and for a micrometer-sized vesicle it dominates. For the formation of one daughter vesicle (conjugated with a 100-nm radius tube) expanded from 1 to 200 microm in radius, the mixing ratios cover almost 3 orders of magnitude. We show that the system can be expanded to linear strings of nanotube-conjugated vesicles that display exponential dilution. Mixing ratios spanning 6 orders of magnitude were obtained in strings of three nanotube-conjugated micrometer-sized daughter vesicles.

Fluorescent Dyes↗

A microfluidics approach to the problem of creating separate solution environments accessible from macroscopic volumes.

We report on a microfluidic device that generates separate solution environments in macroscopic volumes. Spatially distinct patterns are created by emitting fluids from 16 different sources (closely spaced microchannels) into a solution-filled macroscopic chamber. The fluid in neighboring microchannels couples viscously in the macroscopic container, generating one single interdigitated stream. Scanning nanoelectrode amperometry was used for characterizing the concentration landscape and the diffusion zones between solutions running in parallel at different coordinates in the stream. These experiments were complemented by finite element simulations of the Navier-Stokes and mass transport equations to describe the velocity distributions and the diffusion behavior. For in channel flow velocities of 50 mm.s(-1), patterns could persist on the order of millimeters to centimeters in the open volume. The most narrow diffusion zones with widths less than 10 microm (5-95% concentration change) were found some tens of micrometers out in the macroscopic container. We demonstrate that a 14-microm-diameter nearly spherical object (biological cell) attached to a micropipet can be moved from one solution environment to another by a lateral displacement of only 8 microm. The device is suitable for applications where the solution environment around a microscopic or nanoscopic sensor needs to be changed multiple times, i.e., in order to build layered structures, for obtaining binding isotherms, and kinetic information, for example, on ion channels, enzymes, and receptors as well as in applications where different loci on an object need to be exposed to different environments or where complex solution environments need to be created for studies of interfacial chemistry between two streaming layers.

Journal Article↗