PubMed Health⌕ Search

Biomedical subjects

Ozan Akça

Publications and source records attributed to Ozan Akça.

At least 19 recordsLinked to original sources

Optimizing the intraoperative management of carbon dioxide concentration.

PURPOSE OF REVIEW: This review assesses whether there is a carbon dioxide concentration range that provides optimum benefit to the patient intraoperatively. It includes the physiological effects of carbon dioxide on various organ systems in awake and anesthetized individuals and its clinical effects in the ischemia/reperfusion setting. This review will present views on end-tidal or arterial carbon dioxide tension management in the perioperative period. RECENT FINDINGS: Hypocapnia reduces intracranial pressure and is used by clinicians during acute traumatic brain injury, acute intracranial hemorrhage, and acutely growing brain tumors. There is mounting evidence, however, that hypercapnia improves tissue perfusion and oxygenation. Therefore, clinicians may want to induce mild-to-moderate hypercapnia during reperfusion states such as major vascular surgery, organ transplantation, tissue-graft surgery, and cases managed with low mean arterial pressures to control bleeding. As hypercapnia preserves cerebral blood flow even under relatively low perfusion pressures, it may be beneficial during global reperfusion scenarios. This hypothesis needs to be tested extensively before being considered for clinical applications. From a different perspective, current American Heart Association Guidelines recommend 12-15 breaths/min during cardiopulmonary resuscitation and stress the potential negative role of inadvertent hyperventilation on survival outcome. The importance of this concept is discussed briefly. SUMMARY: Overall, the benefits of managing carbon dioxide concentration intraoperatively for the maintenance of cardiac output, tissue oxygenation, perfusion, intracranial pressure, and cerebrovascular reactivity are well defined.

Anesthesia, General↗

Core temperature measurements through a new airway device, perilaryngeal airway (CobraPLA).

STUDY OBJECTIVE: The aim of this study was to test the hypothesis that the intraoperative pharyngeal temperatures obtained on the perilaryngeal airway (PLA), a novel airway device with a larger pharyngeal cuff (when inflated) than the laryngeal mask airway, are similar to tympanic membrane core temperatures. DESIGN: This study is a prospective, simultaneous device comparison. SETTING: This study was set at a university hospital. PATIENTS: The study patients included 14 adults with American Society of Anesthesiologists physical statuses I and II, scheduled for minor gynecological or orthopedic surgery. INTERVENTIONS: A PLA was inserted into the pharynx after induction of general anesthesia. Thermocouples were positioned at 3 sites on the PLA: (1) posterior portion of the head of the airway (tip), (2) midposterior portion of the cuff, and (3) left and right lateral-posterior portions of the cuff. Tympanic membrane thermocouples were inserted. MEASUREMENTS: Temperature readings from the airway and the tympanic membrane thermocouples were recorded every 15 minutes throughout surgery. MAIN RESULTS: Temperatures recorded from the lateral-posterior cuff were found to be virtually identical to tympanic membrane temperatures, with 97% of the values differing by less than 0.5 degrees C. Readings from the other 2 sites on the cuff differed considerably more from tympanic membrane values. CONCLUSIONS: These data suggest that the PLA can be adapted to monitor core temperature reliably.

Adult↗

Effects of nitrous oxide on intraoperative bowel distension.

PURPOSE OF REVIEW: To evaluate evidence and present an objective view on the effect of nitrous oxide on bowel function. RECENT FINDINGS: We determined in a metaanalysis that the chance of having intraoperative bowel distension was increased about two fold in patients receiving nitrous oxide as the anaesthetic carrier gas compared with those receiving nitrogen or oxygen. In a separate logistic regression analysis, we found that the duration of nitrous oxide exposure was a key factor in explaining this difference, as well as the variability of previously published data. In contrast to bowel distension, surgical operating conditions were not hindered by the use of nitrous oxide; however, the number of patients analysed for operating conditions was much less than that for bowel distension data. SUMMARY: Nitrous oxide causes clinically and statistically recognizable bowel distension. This distension, however, does not always exacerbate the surgical conditions, nor does it appear to delay bowel movement or hospital discharge. Although no major problems were noted in bowel functions other than distension, we recommend avoiding nitrous oxide administration during prolonged bowel operations.

Journal Article↗

The timing of acupuncture stimulation does not influence anesthetic requirement.

Studies suggest that acupuncture is more effective when induced before the induction of general anesthesia than afterwards. We tested the hypothesis that electro-acupuncture initiated 30 min before the induction reduces anesthetic requirement more than acupuncture initiated after the induction. Seven volunteers were each anesthetized with desflurane on 3 study days. Needles were inserted percutaneously at four acupuncture points thought to produce analgesia in the upper abdominal area and provide generalized sedative and analgesic effects: Zusanli (St36), Sanyinjiao (Sp6), Liangqiu (Sp34), and Hegu (LI4). Needles were stimulated at 2 Hz and 10 Hz, with frequencies alternating at 2-s intervals. On Preinduction day, electro-acupuncture was started 30 min before the induction of anesthesia and maintained throughout the study. On At-induction day, needles were positioned before the induction of anesthesia, but electro-acupuncture stimulation was not initiated until after the induction. On Control day, electrodes were positioned near the acupoints, but needles were not inserted. Noxious electrical stimulation was administered via 25-gauge needles on the upper abdomen (70 mA; 100 Hz; 10 s). The desflurane concentration was increased 0.5% when movement occurred and decreased 0.5% when it did not. These up-and-down sequences continued until volunteers crossed from movement to no movement four times. The P(50) of logistic regression identified desflurane requirement. Desflurane requirement was similar on the Control (mean +/- sd; 5.2% +/- 0.6%), Preinduction (5.0% +/- 0.8%), and At-induction (4.7% +/- 0.3%; P = 0.125) days. This type of acupuncture is thus unlikely to facilitate general anesthesia or decrease the requirement for anesthetic drugs.

Adolescent↗

Supplemental intravenous crystalloid administration does not reduce the risk of surgical wound infection.

Wound perfusion and oxygenation are important determinants of the development of postoperative wound infections. Supplemental fluid administration significantly increases tissue oxygenation in surrogate wounds in the subcutaneous tissue of the upper arm in perioperative surgical patients. We tested the hypothesis that supplemental fluid administration during and after elective colon resections decreases the incidence of postoperative wound infections. Patients undergoing open colon resection were randomly assigned to small-volume (n = 124, 8 mL.kg(-1).h(-1)) or large-volume (n = 129, 16-18 mL.kg(-1).h(-1)) fluid management. Our major outcomes were two distinct criteria for diagnosis of surgical wound infections: 1) purulent exudate combined with a culture positive for pathogenic bacteria, and 2) Center for Disease Control criteria for diagnosis of surgical wound infections. All wound infections diagnosed using either criterion by a blinded observer in the 15 days after surgery were considered in the analysis. Wound healing was evaluated with the ASEPSIS scoring system. Of the patients given small fluid administration, 14 had surgical wound infections; 11 given large fluid therapy had infections, P = 0.46. ASEPSIS wound-healing scores were similar in both groups: 7 +/- 16 (small volume) versus 8 +/- 14 (large volume), P = 0.70. Our results suggest that supplemental hydration in the range tested does not impact wound infection rate.

Crystalloid Solutions↗

The new perilaryngeal airway (CobraPLA) is as efficient as the laryngeal mask airway (LMA) but provides better airway sealing pressures.

The Laryngeal Mask Airway (LMA) is a frequently used efficient airway device, yet it sometimes seals poorly, thus reducing the efficacy of positive-pressure ventilation. The Perilaryngeal Airway (CobraPLA) is a novel airway device with a larger pharyngeal cuff (when inflated). We tested the hypothesis that the CobraPLA was superior to the LMA with regard to insertion time and airway sealing pressure and comparable to the LMA in airway adequacy and recovery characteristics. After midazolam and fentanyl administration, 81 ASA physical status I-II outpatients having elective surgery were randomized to receive an LMA or CobraPLA. Anesthesia was induced with propofol (2.5 mg/kg IV), and the airway was inserted. We measured 1) insertion time; 2) adequacy of the airway (no leak at 15-cm-H2O peak pressure or tidal volume of 5 mL/kg); 3) airway sealing pressure; 4) number of repositioning attempts; and 5) sealing quality (no leak at tidal volume of 8 mL/kg). At the end of surgery, gastric insufflation, postoperative sore throat, dysphonia, and dysphagia were evaluated. Data were compared with unpaired Student's t-tests, chi2 tests, or Fisher's exact tests; P < 0.05 was significant. Patient characteristics, insertion times, airway adequacy, number of repositioning attempts, and recovery were similar in each group. Airway sealing pressure was significantly greater with CobraPLA (23 +/- 6 cm H2O) than LMA (18 +/- 5 cm H2O, P < 0.001). The CobraPLA has insertion characteristics similar to the LMA but better airway sealing capabilities.

Adult↗

Dexmedetomidine and meperidine additively reduce the shivering threshold in humans.

BACKGROUND AND PURPOSE: Hypothermia might prove to be therapeutically beneficial in stroke victims; however, even mild hypothermia provokes vigorous shivering. Meperidine and dexmedetomidine each linearly reduce the shivering threshold (triggering core temperature) with minimal sedation. We tested the hypothesis that meperidine and dexmedetomidine synergistically reduce the shivering threshold without producing substantial sedation or respiratory depression. METHODS: We studied 10 healthy male volunteers (18 to 40 years) on 4 days: (1) control (no drug); (2) meperidine (target plasma level 0.3 microg/mL); (3) dexmedetomidine (target plasma level 0.4 ng/mL); and (4) meperidine plus dexmedetomidine (target plasma levels of 0.3 microg/mL and 0.4 ng/mL, respectively). Lactated Ringer's solution (approximately 4 degrees C) was infused through a central venous catheter to decrease tympanic membrane temperature by approximately 2.5 degrees C/h; mean skin temperature was maintained at 31 degrees C. An increase in oxygen consumption >25% of baseline identified the shivering threshold. Sedation was evaluated by using the Observer's Assessment of Sedation/Alertness scale. Two-way repeated-measures ANOVA was used to identify interactions between drugs. Data are presented as mean+/-SD; P<0.05 was statistically significant. RESULTS: The shivering thresholds on the study days were as follows: control, 36.7+/-0.3 degrees C; dexmedetomidine, 36.0+/-0.5 degrees C (P<0.001 from control); meperidine, 35.5+/-0.6 degrees C (P<0.001); and meperidine plus dexmedetomidine, 34.7+/-0.6 degrees C (P<0.001). Although meperidine and dexmedetomidine each reduced the shivering threshold, their interaction was not synergistic but additive (P=0.19). There was trivial sedation with either drug alone or in combination. Respiratory rate and end-tidal Pco2 were well preserved on all days. CONCLUSIONS: Dexmedetomidine and meperidine additively reduce the shivering threshold; in the small doses tested, the combination produced only mild sedation and no respiratory toxicity.

Adolescent↗

Minute sphere acupressure does not reduce postoperative pain or morphine consumption.

Minute sphere acupressure has been used for more than 2000 yr and remains popular in Japan. The points most relevant to abdominal surgery are those associated with meridian flows crossing or originating in the abdomen. We tested the hypothesis that minute sphere therapy reduces pain and analgesic requirements after open abdominal surgery. Participating patients were given standardized desflurane and fentanyl anesthetic. On completion of surgery, they were randomly assigned to untreated control or minute sphere acupressure at the Neiguan, Zusanli, Sanyinjiao, and Gongsun points. Each site was covered with bulky gauze dressings so that patients could not determine their assignments. Postoperative pain was treated with IV morphine via a patient-controlled analgesia pump. Our primary a priori end-points were pain and opioid consumption on the first postoperative morning. Data are reported as median (25th percentile, 75th percentile). Fifty-three patients (30 controls and 23 minute spheres) completed the study. Morphine requirements (47 mg [27, 58] vs 41 mg [25, 69]) and pain scores (29.5 mm [16, 59] vs 40 mm [22, 58]) were similar in the control and acupressure groups. These data provide an 80% power for detecting a 50% difference in morphine consumption at an alpha of 0.05. Minute sphere treatment at the Neiguan, Zusanli, Sanyinjiao, and Gongsun points thus failed to provide analgesia after abdominal surgery. Minute sphere therapy is a form of acupuncture. We tested whether minute spheres placed on three acupressure points relevant to abdominal surgery reduced pain and morphine requirements after abdominal surgery. Treatment and control patients received a similar covering. Neither pain nor morphine requirements were different between the groups.

Abdomen↗

The influence of protocol pain and risk on patients' willingness to consent for clinical studies: a randomized trial.

We tested the hypothesis that the risk or discomfort associated with a clinical trial influence patients' decisions to participate. Simultaneously, we evaluated factors likely to influence patients' decisions such as understanding of the risk and discomfort associated with the study, patient age, educational level, and psychological status. With IRB approval, participants, who believed they were being asked to participate in a real trial, were presented one of three sham protocols: no risk or pain (Control, n = 48), pain but no risk (Pain, n = 51), or risk but no pain (Risk, n = 51). Patients were debriefed at the end of the interview. Our major outcome measures were (a) understanding risk or pain associated with the proposed studies, (b) the extent to which patients felt pressured to participate, and (c) willingness to participate. Whereas understanding was similar in all groups (Control, 68%; Pain, 67%; and Risk, 72%), willingness to participate differed significantly (Control, 64%; Pain, 35%; Risk, 26%; P < 0.001). Patients who understood the level of risk or pain associated with the protocols were twice as likely to participate than those who did not (49% versus 24%; P = 0.003). Nine percent agreed to participate in the risky or painful protocols without understanding the risks involved. Patients who felt pressured did not agree to participate. Thus, the consent process protected patients, although for unexpected reasons. Understanding was poor, but patients who did not understand the risks or pain involved or who felt pressured rarely consented. Consequently, relatively few patients unknowingly agreed to participate in risky or painful studies.

Adult↗

Nonpharmacological prevention of surgical wound infections.

Postoperative wound infection is a common and serious complication of surgery. This review will focus on 2 factors known to modulate perioperative immunity: maintenance of perioperative normothermia and provision of supplemental perioperative oxygen. Hypothermia causes numerous adverse outcomes, including morbid myocardial events, increased blood loss and transfusion requirement, postsurgical wound infections, and prolonged hospitalization. Perioperative normothermia should thus be maintained unless therapeutic hypothermia is specifically indicated. Supplemental perioperative oxygen (inspired fraction of 80% instead of 30%) significantly reduces postoperative nausea and vomiting, diminishes the decrease in phagocytosis and bacterial killing usually associated with anesthesia and surgery, and reduces the rate of postoperative wound infection among patients who undergo colon resection. Available data thus suggest that supplemental perioperative oxygen improves surgical outcome with little or no associated risk.

Body Temperature↗

Insufficiency in a new temporal-artery thermometer for adult and pediatric patients.

UNLABELLED: SensorTouch is a new noninvasive temperature monitor and consists of an infrared scanner that detects the highest temperature on the skin of the forehead, presumably over the temporal artery. The device estimates core temperature (T(core)). We tested the hypothesis that the SensorTouch is sufficiently precise and accurate for routine clinical use. We studied adults (n = 15) and children (n = 16) who developed mild fever, a core temperature of at least 37.8 degrees C, after cardiopulmonary bypass. Temperature was recorded at 15-min intervals throughout recovery with the SensorTouch thermometer and from the pulmonary artery (adults) or bladder (children). Pulmonary artery (T(core)) and SensorTouch (T(st)) temperatures correlated poorly in adults: T(core) = 0.7. T(st) + 13, r(2) = 0.3. Infrared and pulmonary artery temperatures differed by 1.3 +/- 0.6 degrees C; 89% of the adult temperatures thus differed by more than 0.5 degrees C. Bladder and infrared temperatures correlated somewhat better in pediatric patients: T(core) = 0.9. T(st) + 12, r(2) = 0.6. Infrared and bladder temperatures in children differed by only 0.3 degrees C, but the SD of the difference was 0.5 degrees C. Thus, 31% of the values in the infants and children differed by more than 0.5 degrees C. IMPLICATIONS: We evaluated a noninvasive infrared forehead thermometer (SensorTouch) in adult and pediatric cardiac patients. Accuracy was poor in the adults and suboptimal in infants and children.

Adult↗

Electro-acupuncture at the Zusanli, Yanglingquan, and Kunlun points does not reduce anesthetic requirement.

UNLABELLED: We tested the hypothesis that electro-acupuncture at the Zusanli, Yanglingquan, and Kunlun acupuncture points on the legs decreases anesthetic requirement. Fourteen young, healthy volunteers were anesthetized with desflurane on two separate days. Needle electrodes were positioned at the three acupuncture points thought to produce a generalized sedative and analgesic effect. Needles were percutaneously placed on treatment days; on control days, they were insulated and taped near the insertion points. The electrodes were stimulated on the treatment day. Stimulation consisted of 2-Hz and 100-Hz currents alternated at 2-s intervals. When the end-tidal desflurane concentration of 5.5% was stable for 15 min, noxious electrical stimuli were administered via 25-gauge needles on both thighs (70 mA at 100 Hz for 10 s). Desflurane concentration was increased 0.5% when movement occurred and decreased 0.5% when it did not. An investigator, blinded to treatment, determined movement. These up-and-down sequences were continued until volunteers crossed from movement to no movement four times. A logistic regression determined the partial pressure of desflurane that produced a 50% likelihood of movement in response to noxious stimulation and consequently identified the minimum alveolar anesthetic concentration equivalent for desflurane. There was no significant difference in minimum alveolar anesthetic concentration equivalents between the electro-acupuncture (4.6% +/- 0.6%, mean +/- SD) and control (4.6% +/- 0.8%) days (P = 0.8). These data provided an 80% power for detecting a difference of 0.35 volume-percent between the groups. IMPLICATIONS: Electro-stimulation of three general acupuncture points on the leg did not reduce desflurane requirements. This type of acupuncture is thus unlikely to facilitate general anesthesia or decrease the need for anesthetic drugs.

Acupuncture Points↗

Initial experience with a novel heat-exchanging catheter in neurosurgical patients.

UNLABELLED: Even mild hypothermia provides marked protection against cerebral ischemia in animal models. Hypothermia may be of therapeutic value during neurosurgical procedures. However, current cooling systems often fail to induce sufficient hypothermia before the dura is opened. Furthermore, they usually fail to restore normothermia by the end of surgery, thus delaying extubation. We evaluated a new internal heat-exchanging catheter. Eight ASA physical status II-IV patients (29-72 yr) undergoing craniotomy were enrolled. After the induction of general anesthesia, we introduced the SetPoint catheter into the inferior vena cava via a femoral vein. The target core body temperature was 34 degrees C-34.5 degrees C. After reaching the target, core temperature was maintained until the dura was closed. Target core temperature was then set to 37.0 degrees C, and the patient was rewarmed as quickly as possible. Seven patients had a tumor resection, and one had an aneurysm clipped. The core-cooling rate was 3.9 degrees C +/- 1.6 degrees C/h, and the rewarming rate was 2.0 degrees C +/- 0.5 degrees C/h; core temperature was 35.9 degrees C +/- 0.2 degrees C by the end of surgery. Patients were subsequently kept normothermic for 3 h before the catheter was removed. No thrombus or other particulate material was identified on the extracted catheters. None of the patients suffered any complications that could be attributed to the SetPoint system or thermal management. IMPLICATIONS: Because current systems for inducing therapeutic hypothermia are too slow, we tested an internal counter-current thermal management system during hypothermic neurosurgery. The SetPoint catheter cooled at 3.9 degrees C +/- 1.6 degrees C/h and rewarmed at 2.0 degrees C +/- 0.5 degrees C/h. Catheter-based internal thermal management thus seems to be rapid and effective.

Adult↗

Hypercapnia improves tissue oxygenation.

BACKGROUND: Wound infections are common, serious, surgical complications. Oxidative killing by neutrophils is the primary defense against surgical pathogens and increasing intraoperative tissue oxygen tension markedly reduces the risk of such infections. Since hypercapnia improves cardiac output and peripheral tissue perfusion, we tested the hypothesis that peripheral tissue oxygenation increases as a function of arterial carbon dioxide tension (PaCO(2)) in anesthetized humans. METHODS: General anesthesia was induced with propofol and maintained with sevoflurane in 30% oxygen in 10 healthy volunteers. Subcutaneous tissue oxygen tension (PsqO(2)) was recorded from a subcutaneous tonometer. An oximeter probe on the upper arm measured muscle oxygen saturation. Cardiac output was monitored noninvasively. PaCO(2) was adjusted to 20, 30, 40, 50, or 60 mmHg in random order with each concentration being maintained for 45 min.(2) (2) RESULTS: Increasing PaCO(2) linearly increased cardiac index and PsqO(2) : PsqO(2) = 35.42 + 0.77 (PaCO(2)), < 0.001. CONCLUSIONS: The observed difference in PsqO(2) is clinically important because previous work suggests that comparable increases in tissue oxygenation reduced the risk of surgical infection from -8% to 2 to 3%. We conclude that mild intraoperative hypercapnia increased peripheral tissue oxygenation in healthy human subjects, which may improve resistance to surgical wound infections.

Adult↗