Accuracy of the apex locating function of TCM Endo V in simulated conditions: a comparison study.

OBJECTIVE: The aim of this study was to evaluate the accuracy of the apex-locating function of the TCM Endo V and to compare the results to these of the Root ZX. STUDY DESIGN: Forty-seven extracted maxillary incisor teeth with mature apices and patent single root canals were used for the study. After the root surfaces were cleaned and access cavities were prepared, the true working lengths (TL) were determined with a #10 stainless steel file. All samples were mounted in an alginate model especially developed to test the apex locators. Both electronic apex locators were used according to the manufacturer's recommendations and adjusted to 0.5-mm accuracy to the apical foramen. EL(1) was designates as the working length measured with Root ZX and EL(2) was designated as the working length measured with TCM Endo V. A paired t test was used to statistically analyze the significance of the mean differences at the 95% confidence interval of the differences (P = .001) among TL, EL(1), and EL(2). RESULTS: There were no statistically significant differences between TL and EL(1), TL and EL(2), and EL(1) and EL(2) (P = .001). Both Root ZX and TCM Endo V gave similar results. CONCLUSIONS: TCM Endo V proved to be as reliable as Root ZX but the use of the device to determine the working length was not easy as Root ZX. Further studies are needed to compare TCM Endo V in clinical conditions with similar electric motor and apex locator combined devices.

Dental Instruments↗

Microhardness of packable composites used as posts condensed with different methods.

The purpose of this in vitro study was to evaluate the microhardness of packable composite compacted with hand or ultrasonic pluggers in post spaces. A total of 168 extracted human anterior teeth were prepared with Gates Glidden and ParaPost drills after obturation. A primer and a dentin-bonding agent were applied to the etched surface. Half of the specimens were compacted with an ultrasonic tip and the other half with a mechanical hand compactor and all specimens were polymerized for each increment. The roots were then sectioned horizontally from 0, 2.5, 3, 3.5, 4, 4.5, and 5 mm starting from the coronal and sliced 2.5-mm long. The microhardness test was applied to each specimen. There were statistically significant differences between ultrasonically and hand-condensed groups in whole specimens (p < 0.001). There were no significant differences between groups of 0, 2.5, and 3 mm until 3.5 mm was reached. After 3.5-mm depth, there were significant differences between the groups (p < 0.001). Ultrasonic condensation of packable composites provided mechanical advantage over hand condensation in root canals measuring microhardness in different depths. However, when microhardness was measured at different depths, values decreased after the depth of 3.5 mm in both condensation groups.

Acid Etching, Dental↗

Microleakage of packable composites used in post spaces condensed using different methods.

The aim of this in vitro study was to evaluate the apical and coronal microleakage of a packable composite material compacted by either hand or ultrasonic condensers when placed in post spaces. Forty-two extracted anterior teeth were used. After conventional obturation of the root canals, parallel post spaces 5 mm in depth and 2 mm in diameter were prepared using Gates Glidden and diamond burs. A primer and a dentin bonding agent (Prime & Bond NT) was applied to the etched surface for 30 seconds and light polymerized for 40 seconds. Surefil packable composite resin was inserted in four equal increments and each polymerized for 40 seconds. Half of the specimens were compacted with an ultrasonic tip and the other half with a mechanical hand compactor. After immersion in the dye, the teeth were sectioned longitudinally and dye penetration was evaluated using a stereomicroscope and microleakage recorded in mm. A One-Way Analysis of Variance indicated the two condensing methods were not statistically different (p>0.05). When microleakage was compared within groups, there was also no statistical difference between coronal or apical microleakage (p>0.05). In an in vitro environment, ultrasonic condensers do not offer any advantage over hand condensers. Both the coronal and apical portions of the root had microleakage indicating that regardless of the condensation method and the use of a packable composite, there is still microleakage that could potentially create further clinical problems.

Analysis of Variance↗

Restorative treatment decision making with unaided visual examination, intraoral camera and operating microscope.

This study assessed the restorative treatment options of the occlusal surfaces of teeth examined with unaided visual assistance, an intraoral camera and an operating microscope. Sixty-eight extracted human molars were mounted to perform mouth models with a premolar in contact on both sides. Four observers examined the models in a phantom head, which simulated clinical conditions, using three techniques: unaided visual examination, intraoral camera and operating microscope. The observers were asked to assess the occlusal surface of each tooth and make a treatment decision based on the following scale: 1) the occlusal surface being sound and "not needing a restoration," 2) the occlusal surface having a subsurface or enamel lesion. No operative treatment was needed at this visit, but special attention was given to this surface at recall visits: "preventive care-defer treatment" and 3) the surface had a carious lesion and "needed a restoration." The teeth were then sectioned in the mesio-distal direction and examined under a stereomicroscope with 10x magnification to determine the true extent of caries. Statistical analysis was conducted by calculating percentages and kappa values of the restorative treatment scores based on examinations by four observers. According to all the observers' treatment decisions, the kappa values were found to be 0.341 (p<0.001), 0.471 (p<0.001) and 0.345 (p<0.001) for unaided visual examination, intra-oral camera and operating microscope, respectively. There was a statistically significant difference between the intraoral camera and the other two methods (p<0.05), while there was no significant difference between the unaided visual examination and operating microscope (p>0.05). As a result of a comparison between the unaided visual examination and operating microscope, the use of an intraoral camera improved the restorative treatment decisions of the occlusal surfaces on posterior teeth.

Bicuspid↗

The assessment of unaided visual examination, intraoral camera and operating microscope for the detection of occlusal caries lesions.

This study compared the efficiency of unaided visual examination, intraoral camera and operating microscope according to a visual scoring system (ERK) at occlusal caries detection. A total of 84 extracted human molars were mounted to create mouth models with a premolar in contact on both sides. The models were examined in a phantom head simulating clinical conditions by four observers using the three techniques: unaided visual examination, an intraoral camera and on operating microscope according to the ERK scale. The teeth were than sectioned in a mesio-distal direction and examined under a stereomicroscope with 10x magnification for histological validation. The sensitivity, specificity, positive predictive and negative predictive values were calculated for the four observers with three techniques and statistical analyses were performed using Friedman and DUNN tests, while strength of agreement was determined by calculating Kappa values. From the data, mean sensitivity values were cal. culated as 0.26, 0.43, 0.49 and mean specificity values as 0.87, 0.80 and 0.73 for unaided visual examination, intraoral camera and operating micro scope, respectively. The Kappa values ranged between 0.187 and 0.301 for visual examination, 0.328 and 0.459 for intraoral camera and 0.363 and 0.516 for operating microscope. As a result, the use of an intraoral camera and operating microscope improved occlusal caries detection according to the ERK scale.

Bicuspid↗