PubMed Health⌕ Search

Biomedical subjects

P A Chiaradía

Publications and source records attributed to P A Chiaradía.

2 recordsLinked to original sources

Solutions containing miotic agents: effects on corneal transendothelial electrical potential difference.

BACKGROUND: Anterior chamber miotic solutions are widely used during anterior chamber surgery. We examined the effects of solutions containing miotic agents such as carbachol and/or acetylcholine on corneal endothelial pumping activity. METHODS: We monitored, in vitro, the transendothelial electrical potential difference of isolated rabbit corneal endothelial preparations. As controls, we used solutions without miotics. RESULTS: We found that a solution containing 55 mM acetylcholine and minimal amounts of salts (Miochol E) maintains transendothelial electrical potential difference some 30% above control levels for up to 4 h. Two other solutions, one including balanced salts and 0.55 mM carbachol (Miostat), the other a mixture of 0.19 mM carbachol and 55 mM acetylcholine plus minimal salts, are adequate to maintain the potential difference at control levels. Lastly, a solution with acetylcholine but without any salts (Miochol) greatly decreases the potential difference, to 30% of the control level, in 100 min. CONCLUSION: Our results indicate that: (1) 55 mM (1%) acetylcholine stimulates the endothelial electrical potential difference; (2) addition of 0.19 mM (0.003%) carbachol negates the stimulatory effect of acetylcholine; and (3) absence of electrolytes severely depresses the endothelial electrical activity.

Administration, Topical↗

Effects of acetylcholine, carbachol, and mannitol on rabbit corneal endothelial function as assessed by corneal deturgescence.

BACKGROUND: Anterior chamber miotic solutions are widely used in ophthalmic surgery to induce pupillary contraction. We investigated whether the acetylcholine, carbachol, or mannitol present in perfusing solutions can affect corneal endothelial function. METHODS: Freshly dissected deepithelized rabbit corneas were mounted in a Dikstein-Maurice chamber at 36 degrees C. The endothelial sides were perfused with six solutions: (A) 55 mM (1%) acetylcholine Cl plus modified balanced salts; (B) control for A, with acetylcholine Cl replaced by sucrose; (C) 0.55 mM (0.01%) carbachol Cl plus balanced salts; (D) balanced salts solution (BS; control for C); (E) 3% mannitol plus modified balanced salts; and (F) modified balanced salts (control for E, with mannitol replaced by sucrose). Corneal thickness was followed for 3 h in each experiment. The effect of solution E did not differ from that of solution F. RESULTS: The carbachol-containing solution produced a small increase in corneal thickness compared to the control solution, while the acetylcholine-containing solution resulted in corneal thickness lower than that in control preparations. CONCLUSION: From these data, acetylcholine is harmless to the endothelium, and may actually stimulate its fluid pump mechanism. Carbachol, on the other hand, appears to have a detrimental effect.

Acetylcholine↗