The accuracy of free-hand cup positioning--a CT based measurement of cup placement in 105 total hip arthroplasties.

We studied 105 patients who received a total hip arthroplasty between June 1985 and August 2001 using freehand positioning of the acetabular cup. Using pelvic CT scan and the hip-plan module of SurgiGATE-System (Medivision, Oberdorf, Switzerland), we measured the angles of inclination and anteversion of the cup. Mean inclination angle was 45.8 degrees +/-10.1 degrees (range: 23.0-71.5 degrees ) and mean anteversion angle was 27.3 degrees +/-15.0 degrees (range: -23.5 degrees to 59.0 degrees ). We compared the results to the "safe" position as defined by Lewinnek et al. and found that only 27/105 cups were implanted within the limits of the safe position. We conclude that a safe position as defined by Lewinnek et al. [13] was only achieved in a minority of the cups that were implanted freehand.

Adult↗

[Intraoperative three-dimensional navigation for pedicle screw placement].

The mobile SIREMOBIL Iso-C(3D) C-arm (Siemens, Erlangen, Germany) is the first device permitting intraoperative, three-dimensional representation of bone structures. A high-resolution, isotropic 3D data cube in the isocenter with sides of approximately 12 cm is calculated simultaneously. The SIREMOBIL Iso-C(3D) is linked to the navigation system. This makes it possible to transfer the generated 3D data directly to the linked navigation system without the need for surgeon-dependent registration. In this prospective clinical trial, we evaluated the accuracy of pedicle screw placement using this device. In 61 patients, a total of 302 pedicle screws were placed. Only in five cases (1.7%) were misplacements of > or =2 mm shown in postoperative control CT. The average fluoroscopy time was 1.28+/-0.56 min, and the average operative duration was 103.26+/-23.3 min. There were no postoperative neurological complications in any of the 30 patients. From these data, we conclude that Iso-C(3D) navigation is a very accurate method for the placement of pedicle screws.

Adolescent↗

[Comparative examination between an angle stable, monokortikal osteosynthesis technique with the conventional plate osteosynthesis at the anterior arm shaft fracture].

With a retrospective Follow-up essay under the use of Matched peer variables the wellbeing course was examined by patient pairs (128 patients) assigned to 64 individually with fractures of the anterior arm shaft. A group which treats others with 2.7 or 3.5 mm DCP/LC-DCP got with the AO Point Contact basic gate (PC-Fix). The well-being course data count after the implantation on a period of 18 months. The Follow-up-rate was 100% for this time period. The patients became for each other on reason of the criteria: assigned to fracture classification, soft partial loss, accompanying injuries and age. Possible complications were: implantation conditional nerve damages, infections, implant failures, delayed healings, pseudarthroses, motion reductions and synostoses. Complications appeared (PC-Fix at 13 patients: respect, DCP: 5). The statistical testing didn't yield any statistically significant advantage for one for the two implants at a p-value of 0.5811 for.

Adult↗

[CT-free image guided acetabulum navigation in clinical routine].

After experimental and preclinical evaluation (HAP Paul Award 2001) of the CT-free image-guided surgical navigation system for acetabular cup placement (SurgiGATE C-arm cup" by Medivision, Switzerland), the system was introduced into clinical routine. The computation of the angular orientation of the cup is based on reference coordinates from the anterior pelvic plane concept. A hybrid strategy for pelvic landmark acquisition has been introduced involving percutaneous pointer-based digitization with the noninvasive biplanar landmark reconstruction using multiple registered fluoroscopy images. From January 2001 to December 2002, a total of 256 consecutive patients with primary osteoarthrosis (mean age 69 years, 161 male, 95 female, 132 left, and 124 right hip joints) were operated on with the hybrid CT-free navigation system. During each operation the angular orientation of the inserted implant was recorded. To determine the placement accuracy of the acetabular components, 50 consecutive patients underwent a CT scan 7-10 days postoperatively to analyze the cup position related to the anterior pelvic plane. This was all done blinded by the same investigator with the planning software of the CT-based navigation system of Medivision. There was no significant learning curve observed for the use of the system. The mean value for postoperative inclination was 43 degrees (SD 3.0, range: 37 degrees -49 degrees ) and for anteversion 19 degrees (SD 3.9, range: 10 degrees -28 degrees ). The resulting system accuracy, i.e., the difference between intraoperatively calculated cup orientation and postoperatively measured implant position showed a mean error of 1.5 degrees for the inclination (maximum 5 degrees, SD 1.1) and 2.4 degrees for the anteversion (maximum 6 degrees, SD 1.3). An accuracy of better than 5 degrees inclination and 6 degrees anteversion was achieved under clinical conditions, which implies that there is no significant difference in performance from the established CT-based navigation methods. Image-guided CT-free cup navigation provides a reliable solution for future THA.

Acetabulum↗

[Iso-C(3D0-assisted) navigated implantation of pedicle screws in thoracic lumbar vertebrae].

The mobile Siremobil Iso-C(3D) C-arm (Siemens AG, Medical Solutions, Erlangen) is the first device that permits the intraoperative three-dimensional (3D) representation of bone structures. A high-resolution isotropic 3D data cube in the isocenter with an edge length of approximately 12 cm is calculated simultaneously. The Siremobil Iso-C(3D) is linked to navigation with the integrated NaviLink interface (Siemens AG, Medical Solutions, Erlangen). This makes it possible to transfer the generated 3D data directly to the linked navigation system Surgigate (Medivision, Oberndorf, Switzerland). In this prospective clinical trial we evaluated the accuracy of pedicle screw placement using the Siremobil Iso-C(3D) C-arm. The results were compared to the conventional approach and other computer-assisted procedures (CT-based navigation, C-arm-based 2D navigation) in historical control groups. A total of 141 pedicle screws were placed in 30 patients (70 thoracic spine, 71 lumbar spine). Only in one single case was misplacement shown in the postoperative control CT scan (0.71%), the lowest rate of incorrect placements of all techniques. Also the lowest average fluoroscopy time (1.28+/-0.56 min) was achieved during the placement of pedicle screws on the spine with Iso-C(3D) navigation at a comparable average OR duration (103.26+/-23.3 min). There were no postoperative neurological complications in all 30 patients. From these data we conclude that Iso-C(3D) navigation of pedicle screws is a very accurate method in the correct placement of pedicle screws.

Bone Screws↗

[Computer-assisted screw osteosynthesis of the posterior pelvic ring. Initial experiences with an image reconstruction based optoelectronic navigation system].

Injuries of the posterior pelvic with combined anterior and posterior instability require the stabilisation of both the anterior and posterior pelvic ring. If the injury only involves the ligamental connections, then a transileosacral osteosynthesis with screws is the minimal invasive and biomechanically suitable method of choice. The difficulty with this approach is the correct placement of the screws. Their position must be monitored intraoperatively in 3 planes (inlet, outlet and lateral viewing). This denotes that conventional methods involve high radiation dosages for the patient and the surgical staff. Having the system readily available and being able to perform updates during the operation, fluoroscopically supported navigation for the treatment of fresh injuries becomes possible. Between October 1999 and December 2000 7 patients with traumatic instability of the posterior pelvic ring were treated by computer assisted percutaneous transileosacral screw osteosynthesis. In each case the osteosynthesis of the ileosacral joint was performed with two cannulated AO 7.3 mm titanium screws. After the operation the screw position was controlled by CT scanning and compared to the data acquired intraoperatively. No patients had infection, and there were no postoperative neurological defects. The postoperative CT scans showed no intraspinal or intraforminal malplacement of the screws. In two cases a slight tangential screwthread penetration through the ventral sacrum was found. Our first experiences with this novel technology are encouraging and clearly demonstrate the advantages of fluoroscopic supported passive navigation systems for the optimal placement of ileosacral screws.

Adolescent↗

[Diagnostic and incidence of the rupture of the posterior cruciate ligament].

The purpose of this article is to evaluate the incidence and to give a general review of the examination of the posterior ligament complex. At least ca. 8-10 % of all severe ligament injuries concern the posterior cruciate ligament, which means, that an estimated 4,000-5,000 Germans suffer a PCL rupture every year. Motor-vehicle accidents are the most common cause of the injury, but sports-related traumas (football, skiing) have increased in recent years. The high number of high-energy mechanisms involved (up to 90 %), cause ligament ruptures often to be associated with other injuries, especially fractures of the femur and tibia head. In polytrauma patients PCL ruptures are frequently recognized very late, because the possibility of this kind of injury is often not considered during the clinical examination. The same holds for the diagnosis of monotrauma patients. The initial step in the evaluation is to obtain a thorough history (including the mechanism of injury) and to perform a physical examination. The instability after a PCL rupture may present as an ACL rupture, because the anterior drawer test seems to be positive. The anterior/posterior drawer test must be assessed with other evaluation procedures to distinguish between anterior und posterior instabilities. The posterior sag sign, the quadriceps active test or the reversed pivot-shift may indicate a PCL rupture. A correct roentgenogram can reveal an avulsion of the tibia and can prove posterior instability due to a posterior translation of the tibia. A quantitative examination (clinical or X-ray) of the instability and the indication of combined injury of the posterior cruciate ligament and the posterolateral complex are necessary for the therapeutic decision (operative/conservative). A rupture of the PCL may occur occasionally as a result of a luxation of the knee (reduced spontaneously) before the medical evaluation. A thorough neurovascular examination is essential. Magnetic resonance imaging can be important to the diagnosis of an acute injury, but it is not essential for the choice between operative and non-operative treatment. Arthroscopy has been found to have a high degree of accuracy in the diagnosis of ligament ruptures of the knee, but it is still an operative treatment, so that it can only be used if an operation of repair or reconstruction is planned anyway. Before operative treatment of chronic complex instability, potential osseous abnormalities (varus morphotype) must be revealed; in case of uncertainty, an X-ray control is necessary.

Cross-Sectional Studies↗

[Cup placement in hip replacement surgery -- A comparison of free-hand and computer assisted cup placement in total hip arthroplasty -- a multi-center study].

AIM: The purpose of the current study was to determine the accuracy of free hand and computer-assisted (CAS) cup placement. MATERIAL AND METHODS: Between June 1985 and August 2001, 105 free-hand and from March to November 1999 80 total hip arthroplasties under computer assistance were implanted in the above mentioned centers. To determine the accuracy of the cups, the inclination and anteversion angles were measured. In all cases the cup position was measured with a CT-investigation of the pelvis. Statistical analysis was performed with the F-test. RESULTS: With regard to the inclination and anteversion angles the variability of the cup position was significantly higher in the group of free hand implanted cups. In the CAS group we could not find any "extreme" positions. CONCLUSION: Using computer-assisted surgery a significantly higher reproducible cup position can be obtained. Long time survey may present a lowering of the rate of early and late complications caused by better prostheses alignment in the follow up.

Adult↗