Electrical alternans during rest and exercise as predictors of vulnerability to ventricular arrhythmias.

This investigation was performed to evaluate the feasibility of detecting repolarization alternans with the heart rate elevated with a bicycle exercise protocol. Sensitive spectral signal-processing techniques are able to detect beat-to-beat alternation of the amplitude of the T wave, which is not visible on standard electrocardiogram. Previous animal and human investigations using atrial or ventricular pacing have demonstrated that T-wave alternans is a marker of vulnerability to ventricular arrhythmias. Using a spectral analysis technique incorporating noise reduction signal-processing software, we evaluated electrical alternans at rest and with the heart rate elevated during a bicycle exercise protocol. In this study we defined optimal criteria for electrical alternans to separate patients from those without inducible arrhythmias. Alternans and signal-averaged electrocardiographic results were compared with the results of vulnerability to ventricular arrhythmias as defined by induction of sustained ventricular tachycardia or fibrillation at electrophysiologic evaluation. In 27 patients alternans recorded at rest and with exercise had a sensitivity of 89%, specificity of 75%, and overall clinical accuracy of 80% (p <0.003). In this patient population the signal-averaged electrocardiogram was not a significant predictor of arrhythmia vulnerability. This is the first study to report that repolarization alternans can be detected with heart rate elevated with a bicycle exercise protocol. Alternans measured using this technique is an accurate predictor of arrhythmia inducibility.

Adolescent

Potency of wild-type or sabin trivalent inactivated poliovirus vaccine, by enzyme-linked immunosorbent assay using monoclonal antibiotics specific for each antigenic site.

Potency testing of inactivated poliovirus vaccine (IPV) is hampered by the absence of a standardized in vitro test, as well as the lack of a generally accepted quantitative animal test. In vitro tests must be able to measure selectively the content of the "D" antigen in the vaccine which includes virus neutralizing antibodies. We tested 12 poliovirus type 1, 12 type 2 and six type 3, D antigen-specific monoclonal mouse antibodies (mAb) for use in the enzyme-linked immunosorbent assay (ELISA). We characterized the site-specific reactivities of three mAbs, one for each poliovirus type. The reactivity of the complete mAb panel encompassed the important antigenic sites on the virus surface of each of the poliovirus serotypes. Some of the mAbs were cross-reactive between wild-type and Sabin strain IPV. At least one mAb of each poliovirus type that was D antigen-specific and reacted with both wild-type and Sabin IPV was directed against an antigenic site thought to be immunogenic in humans. These reagents may be useful for improved standardization of the ELISA for IPV.

Animals

T wave alternans during exercise and atrial pacing in humans.

INTRODUCTION: Evidence is accumulating that microvolt T wave alternans (TWA) is a marker of increased risk for ventricular tachyarrhythmias. Initially, atrial pacing was used to elevate heart rate and elicit TWA. More recently, a noninvasive approach has been developed that elevates heart rate using exercise. METHODS AND RESULTS: In 30 consecutive patients with a history of ventricular tachyarrhythmias, the spectral method was used to detect TWA during both atrial pacing and submaximal exercise testing. The concordance rate for the presence or absence of TWA using the two measurement methods was 84%. There was a patient-specific heart rate threshold for the detection of TWA that averaged 100 +/- 14 beats/min during exercise compared with 97 +/- 9 beats/min during right atrial pacing (P = NS). Beyond this threshold, there was a significant and comparable increase in level of TWA with decreasing pacing cycle length and increasing exercise heart rates. CONCLUSIONS: The present study is the first to demonstrate that microvolt TWA can be assessed reliably and noninvasively during exercise stress. There is a patient-specific heart rate threshold beyond which TWA continues to increase with increasing heart rates. Heart rate thresholds for the onset of TWA measured during atrial pacing and exercise stress were comparable, indicating that heart rate alone appears to be the main factor of determining the onset of TWA during submaximal exercise stress.

Adult

Carbohydrate intolerance after acute gastroenteritis--a disappearing problem in Polish children.

The prevalence of carbohydrate intolerance in Polish children during an acute episode of gastroenteritis was determined. One hundred and seven consecutive children, less than 3 years old, with acute diarrhoea were enrolled into the study. Carbohydrate intolerance (diagnostic criteria: >0.5% reducing substances and stool pH less than 5.5) was diagnosed in 14/107 (13.08%) children: lactose intolerance was present in 12 (11.2%) patients; glucose polymer intolerance in 1 (0.93%) and monosaccharide intolerance in 1 (0.93%). The most important predisposing factor was rotavirus. In all cases the carbohydrate intolerance was transient, resolving within 5 days. Carbohydrate intolerance is also an infrequent problem in Polish children. Restriction of lactose-containing foods (use of lactose-free or low lactose formulas) for the majority of children with gastroenteritis does not seem to be justified.

Age Factors

Exercise-induced T-wave alternans as a marker of high risk in patients with hypertrophic cardiomyopathy.

Microvolt-level T-wave alternans (alternating morphology from beat to beat) during atrial pacing and exercise may predict ventricular tachycardia (VT) and fibrillation (VF) in ischemic heart disease. We tested whether such alternans during exercise could identify high-risk patients with hypertrophic cardiomyopathy (HCM). We studied 14 HCM patients and 9 normal control subjects for T-wave alternans u sing the CH2000 system with 7 multisegment electrodes in a Frank orthogonal (XYZ) configuration. Bicycle ergometer exercise was used to increase the heart rate (HR) to 95-110 beats/min. Seven patients were at high risk for ventricular arrhythmias (1 with sustained VT, 3 with abnormal paced ventricular electrograms as seen in VF survivors, and 3 with nonsustained VT and/or an adverse family history), and the other 7 were at low risk. T-wave alternans was present if alternans > 1.9 microV was consistently present with the HR in excess of a patient-specific HR threshold. Alternans was found in 5 of 7 high-risk patients (71%) vs none of 7 low-risk patients or 9 control subjects (p < 0.025 and p < 0.01, respectively). Notably, all 4 patients with sustained VT or abnormal ventricular electrograms showed alternans. Thus, high-risk patients with HCM often show T-wave alternans. Microvolt-level alternans during exercise may be a useful marker for ventricular arrhythmic risk in patients with HCM.

Adult

Power law behavior of RR-interval variability in healthy middle-aged persons, patients with recent acute myocardial infarction, and patients with heart transplants.

BACKGROUND: The purposes of the present study were (1) to establish normal values for the regression of log(power) on log(frequency) for, RR-interval fluctuations in healthy middle-aged persons, (2) to determine the effects of myocardial infarction on the regression of log(power) on log(frequency), (3) to determine the effect of cardiac denervation on the regression of log(power) on log(frequency), and (4) to assess the ability of power law regression parameters to predict death after myocardial infarction. METHODS AND RESULTS: We studied three groups: (1) 715 patients with recent myocardial infarction; (2) 274 healthy persons age and sex matched to the infarct sample; and (3) 19 patients with heart transplants. Twenty-four-hour RR-interval power spectra were computed using fast Fourier transforms and log(power) was regressed on log(frequency) between 10(-4) and 10(-2) Hz. There was a power law relation between log(power) and log(frequency). That is, the function described a descending straight line that had a slope of approximately -1 in healthy subjects. For the myocardial infarction group, the regression line for log(power) on log(frequency) was shifted downward and had a steeper negative slope (-1.15). The transplant (denervated) group showed a larger downward shift in the regression line and a much steeper negative slope (-2.08). The correlation between traditional power spectral bands and slope was weak, and that with log(power) at 10(-4) Hz was only moderate. Slope and log(power) at 10(-4) Hz were used to predict mortality and were compared with the predictive value of traditional power spectral bands. Slope and log(power) at 10(-4) Hz were excellent predictors of all-cause mortality or arrhythmic death. To optimize the prediction of death, we calculated a log(power) intercept that was uncorrelated with the slope of the power law regression line. We found that the combination of slope and zero-correlation log(power) was an outstanding predictor, with a relative risk of > 10, and was better than any combination of the traditional power spectral bands. The combination of slope and log(power) at 10(-4) Hz also was an excellent predictor of death after myocardial infarction. CONCLUSIONS: Myocardial infarction or denervation of the heart causes a steeper slope and decreased height of the power law regression relation between log(power) and log(frequency) of RR-interval fluctuations. Individually and, especially, combined, the power law regression parameters are excellent predictors of death of any cause or arrhythmic death and predict these outcomes better than the traditional power spectral bands.

Adult

Exercise recordings for the detection of T wave alternans. Promises and pitfalls.

Despite significant advances in the treatment of sudden cardiac death, many individuals still go untreated because routine clinical tests do not identify them to be at risk. Recently, a study to identify individuals at risk has shown that the presence of T wave alternans (TWA), a fluctuation in T wave morphology occurring on an every-other-beat basis, is an accurate predictor of subsequent ventricular tachyarrhythmic events. T wave alternans as low as a few microvolts was found to be significant in predicting risk. Since TWA is often detectable only at elevated heart rates, the study used atrial pacing to increase the heart rate to approximately 100 beats/min. To make TWA measurement more broadly applicable, the authors have developed a methodology that uses noninvasive physiologic stress to raise the heart rate. A particular challenge was the measurement of TWA during exercise, since the levels of noise during exercise can far exceed the levels of TWA. However, by using special multisegment Hi-Res electrodes (Cambridge Heart, Bedford, MA), noise reduction software, and a spectral method of alternans analysis, the authors have been able to reduce noise and reliably measure microvolt-level alternans. This study presents an overview of the methodology for recording and analyzing microvolt-level TWA during ergometer exercise.

Adolescent

Predicting sudden cardiac death from T wave alternans of the surface electrocardiogram: promise and pitfalls.

Sudden cardiac death remains a preeminent public health problem. Despite advances in preventative treatment for patients known to be at risk, to date we have been able to identify, and thus treat, only a small minority of these patients. Therefore, there is a major need to develop noninvasive diagnostic technologies to identify patients at risk. Recent studies have demonstrated that measurement of microvolt-level T wave alternans is a promising technique for the accurate identification of patients at risk for ventricular arrhythmias and sudden cardiac death. In this article, we review the clinical data establishing the relationship between microvolt T wave alternans and susceptibility to ventricular arrhythmias. We also review the methods and technology that have been developed to measure microvolt levels of T wave alternans noninvasively in broad populations of ambulatory patients. In particular, we examine techniques that permit the accurate measurement of T wave alternans during exercise stress testing.

Artifacts

Occult T wave alternans in long QT syndrome.

T wave alternans that is visually apparent on the ECG is a known risk factor for sudden death in idiopathic long QT syndrome (LQTS). To determine if occult and visually undetectable forms of T wave alternans are also present in LQTS, we measured T wave alternans from a 16-year-old girl with LQTS during exercise using spectral analysis methods and a recording system designed to minimize exercise-related noise. While there was no alternans at rest, statistically significant, yet visually inapparent T wave alternans were measured both during exercise and recovery. Using identical recording techniques, no significant T wave alternans was detected from the subject's mother, who had a prolonged QT interval but was not experiencing arrhythmias, nor from five healthy volunteers with normal QT intervals. This report suggests that electrocardiographically occult, yet prognostically important forms of T wave alternans may be present in patients with LQTS.

Adolescent

Changing levels of measles antibody titers in women and children in the United States: impact on response to vaccination. Kaiser Permanente Measles Vaccine Trial Team.

OBJECTIVES: In the United States, younger women are more likely to have immunity to measles from vaccination and are less likely to have been exposed to the wild virus than are older women. To evaluate changes in measles antibody titers in women in the United States and children's responses to measles vaccination, we analyzed data from a measles vaccine trial. METHODS: Sera collected from children before vaccination at 6, 9, or 12 months of age and from their mothers were assayed for measles antibodies by plaque reduction neutralization. Responses to vaccination with Merck Sharp & Dohme live measles virus vaccines at 9 months (Attenuvax) and 12 months (M-M-R II) were also analyzed. RESULTS: Among women born in the United States (n = 614), geometric mean titers (GMTs) of measles antibodies decreased with increasing birth year. For those born before 1957, 1957 through 1963, and after 1963, GMTs were 4798, 2665, and 989, respectively. Among women born outside of the United States (n = 394), there were no differences in GMTs by year of birth. Children of younger women born in the United States were less likely than those of older women to be seropositive at 6, 9, or 12 months. The response to the vaccines varied by maternal birth year for children of women born in the United States. Among 9-month-old children, 93% of those whose mothers were born after 1963 responded, compared with 77% and 60% of those whose mothers were born in 1957 through 1963 and before 1957, respectively. Among 12-month-old children, 98% of those born to the youngest mothers responded, compared with 90% and 83% of those whose mothers were born in 1957 through 1963 and before 1957. The responses of children of women born outside of the United States were not associated with maternal year of birth. CONCLUSIONS: An increasing proportion of children in the United States will respond to the measles vaccine at younger ages because of lower levels of passively acquired maternal measles antibodies.

Adult

[Protein hydrolysates in infant formulas].

The paper describes protein hydrolysates methods of hydrolysis, classification of hydrolysates based on the type of hydrolysed protein and extent of hydrolysis, conditions which should be fulfilled to ensure the hypoallergenicity (hypoantigenicity) of hydrolysed formulae. The indications for use in treatment and prevention are discussed.

Child, Preschool

Measles vaccination of infants in a well-vaccinated population.

During outbreaks of measles, measles vaccine is recommended for infants considered to be at risk who are 6 months of age and older. In a prospective trial the serologic response to early measles immunization has been evaluated in 125 infants given monovalent measles vaccine at 6 to 8.5 months of age and measles-mumps-rubella at 15 months. The response to vaccination was measured by plaque reduction neutralization (PRN) assay and enzyme immunoassay. Infants were grouped by the mother's immunization history: natural immunity (n = 60, Group 1); killed followed by live, further attenuated vaccine (n = 22, Group 2); and live, further attenuated vaccine only (n = 43, Group 3). The prevaccination geometric mean titer (GMT) by PRN for Group 1 (GMT = 69) was significantly higher than that of Group 2 (GMT = 18) or 3 (GMT = 13). Seroconversion (4-fold increase in PRN titer) rates after monovalent vaccine were 31, 71 and 76% for Groups 1, 2 and 3, respectively. Seroconversion percentages were higher when measured 6 to 8 weeks after vaccination compared with 4 to 5 weeks. After measles-mumps-rubella > or = 97% of all infants had PRN titers > 120 and were measles IgG-positive by enzyme immunoassay. These data show that as demographics shift to a well-vaccinated maternal population and susceptibility in younger infants, measles vaccination before the currently recommended age will be effective.

Age Factors

Kinetics of cycle length dependence of ventricular repolarization: effect of autonomic blockade.

INTRODUCTION: Beat-to-beat adaptation of ventricular repolarization duration to cardiac cycle length and autonomic activity has not been previously characterized in the spontaneously beating human heart. METHODS AND RESULTS: The ECG of 14 healthy subjects was recorded from the supine and upright positions. Autonomic blockade was accomplished by atropine and propranolol. RR and RT intervals were measured by a computer algorithm, and the impulse response (h) from RR to RT computed. In the supine position the maximal adjustment of the RT interval occurred in the first beat following a change in cycle length (hpeak = 17.8 +/- 1.6 msec/sec), but continued to be detectable for 3.8 seconds (2.9-4.7 sec). Propranolol attenuated the peak impulse response to 15.8 +/- 4.0 msec/sec (P = NS). In the standing position the peak impulse response was increased to 25.2 +/- 5.0 msec/sec (P = 0.004 vs supine), and the impulse response duration (hdur) shortened to 1.4 seconds (1.3-1.6). This was reversed by beta blockade (hpeak = 10.7 +/- 3.6 [P = 0.005 vs standing]; hdur = 5.5 sec [4.8-6.1]). Parasympathetic and combined autonomic blockade resulted in too little residual heart rate variability to estimate the impulse response accurately. The slope of the regression of delta RT and delta RR in the supine position was 0.0177 +/- 0.0016, which was closely correlated with the peak impulse response (r = 0.91). CONCLUSIONS: System identification techniques can assist in characterizing the cycle dependence of ventricular repolarization and may provide new insights into conditions associated with abnormal repolarization.

Adult

Early loss of passive measles antibody in infants of mothers with vaccine-induced immunity.

BACKGROUND: Maternally derived passive measles antibody may interfere with vaccine-induced immunity in infants less than 12 months of age. However, early loss of passive measles antibody may occur in infants of women who received measles vaccine because measles vaccine induces lower antibody titers than does natural infection. METHODS: Persistence of passive neutralizing measles antibody was studied longitudinally in a group of normal infants as a function of maternal measles titer at birth and maternal date of birth. Maternal serum and cord blood specimens were tested from 162 women and their newborns, from 51 of these infants at 9 months of age and from 63 at 12 months of age. RESULTS: Seventy-one percent of sera from 9-month-old infants (36 of 51, 95% confidence interval 68% to 84%) and 95% of samples from 12-month-old infants (60 of 63, 95% confidence interval 89% to 101%) had no detectable neutralizing measles antibody. Measles geometric mean titers were significantly higher at delivery in mothers whose infants were seropositive at 9 and 12 months compared with mothers whose infants were seronegative at 9 and 12 months. All infants with detectable measles antibody at 9 or 12 months had mothers born before 1963, before the vaccine era, and both material and cord blood measles geometric mean titers decreased significantly with decreasing maternal age. CONCLUSIONS: Persistence of passive measles antibody is uncommon by 12 months of age; earlier antibody loss is related to lower maternal age and maternal measles titer.

Antibodies, Viral

[Infant formula follow-up: an update].

The work presents and comments on, the recommendations of the European Society of Pediatric Gastroenterology and Nutrition, European Communities Commission and FAO/WHO regarding the composition of infant formulae and follow-up formulae. The survey is aimed at facilitating selection of adequate formula's out of their abundance on the Polish market.

Food, Formulated

Deleterious effect of thimerosal on the potency of inactivated poliovirus vaccine.

High-potency inactivated poliovirus vaccine (eIPV) was combined with diphtheria-tetanus-pertussis (DTP) vaccine containing thimerosal as a preservative to simulate the performance of a potential tetravalent vaccine. Neither type 1 nor type 3 poliovirus antigens appeared to be affected by thimerosal after exposure for 1 h at 37 degrees C as measured by enzyme-linked immunosorbent assay (ELISA). One epitope on the type 2 antigen was damaged within 5 min of exposure; however, the overall potency was unchanged when measured using a polyclonal antibody preparation. Exposure to thimerosal at 37 degrees C decreased the potency of all three poliovirus types to well below the level caused by heat deterioration alone in 1-2 days and to 0% after 16-17 days. At 25 degrees C, the potency of type 1 poliovirus decreased by 46% in 1 day, whereas poliovirus types 2 and 3 were stable for 1 week. Storage of eIPV at 4 degrees C in the presence of thimerosal reduced the potency of type 1 poliovirus antigen to undetectable levels after 4-6 months. Type 2 and 3 antigens were less markedly affected by 8 months of exposure to thimerosal at 4 degrees C. The loss of potency of type 1 as measured by ELISA was paralleled by a reduced level of neutralizing antibodies in mice injected with these preparations. The results obtained from testing eIPV in combination with DTP and thimerosal were generally similar to those obtained using eIPV with thimerosal. It remains to be seen to what extent thimerosal will affect the immunogenicity of eIPV in humans when injected as combined eIPV-DTP vaccine.

Animals